Using LTE/LTE-A TDD Analyzer
148
NOTE
You can view detailed current resource block on the I-Q diagram, particularly in a dynamic field environment.
8
Tap
Uplink-Downlink Config
and select the number of uplink/downlink using the on-screen keyboard.
9
Optional.
Tap
Miscellaneous
under
Menu
to
do the following as needed.
a
To select the number of antenna ports, tap the
MIMO
and select
2x2
or
4x4
.
b
To assign a antenna port number automatically or manually, tap the
Antenna Port
under
Antenna menu
and select the
option:
Auto
,
Antenna
0
,
Antenna
1
,
Antenna
2
, or
Antenna
3
.
If the MIMO is set to 2x2, the antenna ports 2 and 3 are disabled.
c
To turn the Multimedia Broadcast Multicast Service (
MBMS
) feature on or off, tap
MBMS
and select
On
or
Off
. For proper
MBMS testing, you need to set the
Subframe Number
in the upper right screen with the same PMCH subframe number.
If this setting is on, the measurement item MBSFN RS appears in the result table.
d
To set the Multicast Broadcast Single Frequency Network (
MBSFN
) detection automatically or manually for MBMS
testing, tap
MBSFN
and select
Auto
or
Manual
.
An automatically detected or manually entered MBSFN ID appears on the screen.
e
To set the delay, tap
Delay
and enter the value using the on-scre
en keyboard to set the amount of delay in μs.
NOTE:
The Delay setting is used only when there is a time offset in the signals to be measured.
f
To select the Cyclic Prefix, tap
Cyclic Prefix
and select
Normal
or
Extended
.
g
To set the threshold for PDSCH, tap
PDSCH Threshold
and enter a value by using the on-screen keyboard.
h
Tap
PDSCH Modulation Type
, and then select the modulation type option:
Auto, QPSK, 16 QAM, 64 QAM, 256 QAM,
E-TM3.3, E-TM3.2, E-TM3.1a, E-TM3.1, E-TM2a, E-TM2, E-TM1.2 or E-TM1.1
.
If two or more modulation types are used in a frame, select
Auto
. If the PDSCH uses the same modulation type in a
frame or in a subframe, select a specific modulation type to get more accurate EVM.
i
Tap
PDSCH Precoding
to set
On
or
Off
to enable or disable the PDSCH precoding.
Setting limit
1
Tap
Menu
>
Limit
.
2
Tap to switch the
Data EVM RMS/Data EVM Peak/IQ Origin Offset
to set the
Test limits
to
On
or
Off
with setting
High Limits
using the on-screen keyboard to enable or disable Pass/Fail indication.
Using marker
You can use
Marker
to place a marker on a resource block and display the IQ diagram for the selected resource block.
1
Tap
Menu
>
Marker
.
2
Tap
RB Number
to select the resource block to be marked and enter the resource block number using the on-screen keyboard.
The marker appears on the selected resource block.
3
Tap
Marker View
between
On
and
Off
to display or dismiss the result of the selected resource block.
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......