Operation,
Screen Layout and Navigation
1-2-3
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 34
Subject to Export Control. See Cover Page for details.
September 2021
3.4.19.1
TCAS Block Transmission Add Message Screen
The Block Transmission Add Message Screen allows the user to define the parameters for the new
message that is added and allows selection of 1030/1090 messages, Mode S/ATCRBS, power, phase
and transmission time.
SCREEN SEQUE NCE:
TCAS Block Transmission Screen > Block Transmission Softkey > Add Message Softkey
F i g u re 1 . 2 . 3 - 3 3 T C A S B l o c k T ra n s m i s s io n A d d M e s s a g e Sc r e e n / M en us
Screen Components
Description
Message Type Menu
Selects the Message Type.
Message Name Menu
Selects the Message Name, the subcategory of message within the
Message Type selected.
EX A MP L E :
If the Message Type is Mode S Replies, the Message
Name is DF0, DF4, DF5, DF16, et c.
Frame Details Softkey
This softkey is available when the selected block contains frame data.
Accesses the Frame Details Screen. Refer to Section
Block Transmission Add Message Frame Detail Screen
.
Address Originator Field
Selects the value used in the AP field to generate the PI field of a Mode
S reply. [DF Messages]
Power Level Field
Selects the Power Level of the message.
Time Field
Selects the transmission time within the block of messages.