Operation,
Remote Operation
1-2-5
RGS-2000NG TCAS Test Set Operation Manual
139187 / Rev. 500
Page 34
Subject to Export Control. See Cover Page for details.
September 2021
5.8.5
RESET
5.8.6
SAVE
5.8.7
SPECIAL TEST
The follow set of commands allow the user to setup some specifi c tests in RTCA DO-260 document. The
special tests provided by the Unit are Altered Preamble, BIT Failure, Confidence Test, Overlapping, and
Preamble Validation.
5.8.7.1
Altered Preamble Parameters
5.8.7.1.1
Pulse Enable
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:RESET}CR
Description:
This command initializes the DO-260 test to the default values.
Attribute
Value
Test Type
Normal
Trigger Source
GENA
Trigger Mode
Delay+
Period (ms)
10
Number of Transmissions
0 to Unlimited
Signal (All Generators)
OFF
Power (All Generators)
-20 dBm
Phase (All Generators)
0 deg
Path (All Generators)
Top
Delay (All Generators)
0 ns
Message Type
None
Example:
:RGS:DO260:RESET\r
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:SAVE}SP<filename>CR
Description:
This command saves the current scenario into the internal storage area with
the specified filename.
Example:
:RGS:DO260:SAVE Test260.csv\r
Command Syntax:
{:RGS | :RGS2000NG}{:DO260}{:TYPE}{:ALTEREDPREAMBLE |
:ALT}{:PULSE}{:P1 | :P2 | :P3 | :P4}{:ENABLE }SP{ON | OFF}CR
Description:
This command enables or disables the selected pulse.
Default:
On
Example:
:RGS:DO260:TYPE:ALT:PULSE:P1:ENABLE ON\r