ArcLight Hub User’s Guide
Component Operating Procedures
Rev. 001
1081006
5-67
Step Display
or
Function
Procedure/Description
Front Panel Display
Over-the-air Test
Perform and over-the-air test as follows:
Note:
Make sure that near station is
transmitting non-null data during initial
acquisition or you may get an invalid
acquisition lock.
Note:
After initial acquisition, a
continuous 24-hour period is required
for the software to determine and store
an accurate round-trip time estimation.
If a brief signal loss or power outage
should occur after the 24-hour period,
the unit will maintain the correct round-
trip time. However, if there is a long
signal loss or power outage, the software
must go through a new acquisition lock
and 24-hour period.
N/A
Transmit non-null
data
Ensure non-null data is being
transmitted from the near station’ s
modem.
N/A
Enable PCMA
Go to CANCELLER | Setup | Canceller
Enable menu and select ON.
Canceller Enable – ON
PCMA ENABLE LED - Lit
Acquire PCMA
Lock
Observe LOCK LED lights indicating
signal acquisition is complete.
PCMA LOCK LED - Lit
6.
Transmit and
receive data for 24
hours
Operate the link normally for a 24-hour
period to determine and store an
accurate round-trip time.
N/A
Note
:
*This parameter’s value is stored in flash memory which requires 5-10 seconds to complete. A
front panel display message is shown during the flash write. DO NOT cycle power during the flash
function or the unit may become inoperative requiring shipment to the factory for repair.
A reboot is required after all flash resident values have been changed.
5.12.5 Operation
This section identifies some additional procedures useful in operating
the VPCMA-70.
5.12.5.1
Configuring VPCMA-70 Remote Control
The VPCMA-70 may be operated remotely using user-provided SNMP
Manager application software loaded on a computer that is connected
to the Ethernet connector on the rear panel, once the SYSTEM network
access parameters have been configured. To operate in this manner,
perform the following procedures.
1.
Ensure the SNMP Manager application software is loaded
and operational on the Remote Controller Computer.
2.
Ensure the Remote Controller Computer is connected
properly.
Содержание ArcLight
Страница 2: ......
Страница 3: ...ArcLight TM Hub User s Guide ViaSatDocument Number 1081006 Rev 001 ...
Страница 4: ......
Страница 5: ...ArcLightTM Hub User s Guide ...
Страница 6: ......
Страница 7: ...ArcLight TM Hub User s Guide ViaSatDocument Number 1081006 Rev 001 ...
Страница 9: ......
Страница 10: ......
Страница 12: ...ArcLight Hub User s Guide iv 1081006 Rev 001 ...
Страница 35: ...ArcLight Hub User s Guide Rev 001 1081006 xxvii ...
Страница 36: ......
Страница 64: ...ArcLight Hub User s Guide General System Description 1 28 1081006 Rev 001 ...
Страница 70: ...ArcLight Hub User s Guide Initial Network Configuration 2 6 1081006 Rev 001 ...
Страница 237: ...ArcLight Hub User s Guide Screen Descriptions for NMS Client Rev 001 1081006 3 167 ...
Страница 238: ......
Страница 364: ...ArcLight Hub User s Guide A 2 1081006 Rev 001 ...
Страница 366: ...ArcLight Hub User s Guide B 2 1081006 Rev 001 ...
Страница 368: ...ArcLight Hub User s Guide I 2 1081006 Rev 001 ...