background image

IMPORTANT SAFETY INSTRUCTIONS:

CAUTION: To reduce risk of electrical shock or electrocution:

-  Do not disassemble.  Do not attempt repairs or   

 

  modifications.  Refer to qualified service agencies for all  
  service and repairs.
-  Do not use this product in or area where it can fall or be    
  pulled into water or other liquids.
-  Do not reach for this product if it has fallen into liquid. 
-  Use this compressor with 12-volt DC systems only.
-  This product should never be left unattended during use.

WARNING: To prevent injuries:

-  Never allow children to operate this compressor.   
  Close supervision is necessary when this compressor  
  is being used near children.
-  This compressor will become very hot during and  
  immediately after use.  Do not touch any part of this  
  compressor with bare hands other than the 
  ON/OFF switch during and immediately after use. 
-  Do not use this product near flames or explosive 
  materials or where aerosol products are being used.
-  Do not operate this product where oxygen is  
  being administered. 
-  Do not pump anything other than atmospheric air.
-  Never use this product while sleepy or drowsy.
-  Do not use any tools or attachments without first  
  determining maximum air pressure for that tool  
  or attachment.
-  Never point any air nozzle or air sprayer toward  
  another person or any part of the body.
-  This air compressor is equipped with an Automatic  
  Reset Thermal Protector, and can automatically restart  
  after the thermal protector resets.  Always cut off power    
  source when thermal protector becomes activated.  
-  Wear safety glasses or goggles when operating this product.
-  Use only in well ventilated areas.

200 PSI FAST-FILL AIR SOURCE KIT

USER MANUAL

Содержание 20003

Страница 1: ...tor of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE Only Compressor is CE Certified 200 PSI FAST FILL AIR SOURCE KIT 55 Duty Compressor on 2 0 Gallon Air Tank PART NO 20007 ...

Страница 2: ...h any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or attachments...

Страница 3: ... possible so that length of positive lead wire required is at a minimum 3 Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES The cooler the ambient temperature the less chance the compressor will overheat 4 The compressor is moisture splash resistant but NOT WATERPROOF Do not mount air source kit in locations where the unit is likely to come in contact with water 5 If ...

Страница 4: ...line connection Tighten compression fitting nut securely using a wrench 6 Connect ground Black wire to a clean ground preferably a chassis ground and secure with a self tapping screw 7 Connect positive Red lead wire from pre installed pressure switch to a fuse holder 20 amp minimum 8 Once the kit is properly fused as close as possible to the power source connect and test compressor system by runni...

Страница 5: ...ill automatically cut off power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off do not attempt to restart air compressor Turn power switch to the air compressor to the OFF position The automatic thermal overload protector will automatically ...

Страница 6: ... Drain water from tank by opening the drain cock drain valve c If drain cock is plugged release all air pressure from tank remove drain valve and clean then reinstall d After condensate has been drained close the drain cock IMPORTANT Observe air tank Date of Manufacture stamped on tank leg Replace air tank 2 to 5 years from date air tank was first used or use the date of manufacture as reference Y...

Страница 7: ...in On 34 Min Off 17 7 Min On 30 Min Off 20 8 Min On 32 Min Off 22 9 Min On 30 Min Off 25 10 Min On 30 Min Off 30 13 Min On 30 Min Off 33 15 Min On 30 Min Off 100 Continuous Duty ABOUT RATED WORKING PRESSURE To ensure trouble free service life of your compressor always operate compressor within rated working pressure of the compressor Never use a pressure switch with a higher cut off pressure than ...

Страница 8: ...normal 1 Excessive air usage 2 Loose connections 3 Worn piston ring or inlet valve 4 Clogged air filter element 1 Decrease air usage 2 Check all connections wit soap and water solution and tighten 3 Repair or replace compressor 4 Replace air filter element Compressor runs continuously causing safety valve if equipped to open 1 Bad pressure switch 2 Defective safety valve 1 Replace pressure switch ...

Страница 9: ...ct fuse amperage 3 Let compressors cool off for about 30 Minutes to allow thermal overload switch reset 4 Replace pressure switch Thermal overload protector cuts out repeatedly 1 Lack of proper ventilation or ambient temperature too high 2 Compressor valves failed 1 Move compressor to well ventilated area or area with lower ambient temperature 2 Repair or replace compressor Excessive knocking or r...

Страница 10: ...e contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTI...

Отзывы: