24
8.2 Boiler output setting
In following tables (table nr. 5 and table nr. 6) there are stated only orientation values and are valid
only for tested fuel.
Tested fuel:
pelets Ø 8 mm
Efficiency
16,4
MJ/kg
Table nr. 5 Boiler output adjustment - VIADRUS HERCULES ECO – 5 sections
Boiler
output
[kW]
Time for fuel
feeding [s]
Time for fuel
afterburning [s]
Quantity of combustion air [%]/
Adjustment of starling flap of the fan on
nr.
7
5
85
30 % / 3
8
5
71
25 % / 2,5
9
5
62
20 % / 2
10
5
55
35 % / 3,5
11
5
49
40 % / 4
12
5
44
45 % / 4,5
13
5
40
50 % / 5
14
5
37
50 % / 5
15
5
34
55 % / 5,5
16
5
32
60 % / 6
17
5
29
65 % / 6,5
18
5
27
70 % / 7
19
5
26
70 % / 7
20
5
24
75 % / 7,5
21
5
23
80 % / 8
22
5
22
85 % / 8,5
23
5
21
85 % / 8,5
24
5
20
90 % / 9
0
10
20
30
40
50
60
70
80
90
5
7
9
11
13
15
17
19
21
23
25
Výkon kotle [kW]
Č
a
s
pr
o
doho
ř
íván
í p
a
liva [s]
Picture nr. 19 Boiler output graph on time of fuel afterburning at the same time for fule feeding (5 s)
for boiler VIADRUS HERCULES ECO - 5 sections
T
ime for fuel afterburning
[
s
]
Boiler output
[
kW
]