Vexar CD36TN-M Скачать руководство пользователя страница 1

Save this manual for future reference.

For more information, visit www.desatech.com

WARNING: If the information in this manual is not fol-

lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

—  Do  not  store  or  use  gasoline  or  other  flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali

-

fied installer, service agency or the gas supplier.

DIRECT-VENT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

NATURAL OR PROPANE/LP GAS 

MODEL CD36TN-M

Содержание CD36TN-M

Страница 1: ...is or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneig...

Страница 2: ...he Mobile Home Standard CAN CSA Z240 MH Series in Canada This fireplace is only for use with the type s of gas indicated on the rating plate A conversion kit is supplied with the fireplace This firepl...

Страница 3: ...d completely beforetryingtoassemble operate orservicethisfireplace Improper useofthisfireplacecancauseseri ousinjuryordeathfromburns fire explosion electrical shock and carbon monoxide poisoning DANGE...

Страница 4: ...person 5 You must keep control compartments burn ers and circulating air passages clean More frequent cleaning may be needed due to ex cessive lint and dust from carpeting bedding material etc Turn of...

Страница 5: ...eplace and venting is a balanced and sealed gas oper ating unit It is highly efficient because it uses outside air for combustion while independently heating the indoor air Figure 2 Common Fireplace L...

Страница 6: ...iscard the bottom tray once the unit is moved into position Clearances Minimum clearances to combustibles for the fire place are as follows Back and sides 0 Perpendicular walls 12 Floor 0 Ceiling to l...

Страница 7: ...NAILING FLANGES 56 3 4 12 1 4 TO OPENING 28 5 8 These dimensions allow for 1 of clearance at the sides and back of fireplace 0 clearance is also permitted at all sides if framed Figure 6 Unit Dimensi...

Страница 8: ...Figure 7 Clearances for Combustible Mantels MANTEL CLEARANCES Figure 7 shows projected mantel depths at various heights above the top of the louver opening Figure 8 shows the minimum allowable distanc...

Страница 9: ...minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a ro...

Страница 10: ...s ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination WARNING Read all instruc tionscompletelyandthoroughly before attempting installation Fa...

Страница 11: ...king lugs indentations These lugs will slide straight into matching slots on the male ends of adjacent pipes Push pipe sec tions together and twist one section clockwise approximatelyone quarterturnun...

Страница 12: ...n to vent cap see Figure 13 8 Carefully move fireplace with vent assembly attached toward wall and insert vent pipe into horizontal termination The pipe overlap should be a minimum of 11 4 9 Place fir...

Страница 13: ...1 4 Min 1 30 Max 69 1 4 Min 2 74 Max 81 1 2 Min 3 98 Max 94 Min 4 122 Max 106 Min 5 146 Max 159 Min 9 20 Max T O H Wall Firestop Straight Adjustable Pipe 24 Max Horizontal Square Termination 90 Elbow...

Страница 14: ...Venting Using Two 90 Elbows Venting with Two 90 Elbows Vertical V Horizontal H Horizontal H2 7 Min 10 Max 8 Min 12 Max 9 Min 14 Max 10 Min 16 Max 11 Min 18 Max 13 Min 20 Max 90 Elbow 90 Elbow T O H Fi...

Страница 15: ...s a center point The open ing should be framed to 10 3 4 x 10 3 4 inside dimensions as shown in Figure 11 on page 11 using framing lumber the same size as the ceiling joists If the area above the ceil...

Страница 16: ...te knockout area for vent pipe 2 Cut and frame ceiling joist to dimensions shown in Figure 11 page 11 3 Determine where firestop plate should be at tached to thimble by test fitting thimble into frami...

Страница 17: ...uration Using Two 90 Elbows Vertical Round High Wind Termination Figure 25 Vertical Venting Configuration with No Horizontal Run Vertical Round High Wind Termination Vertical Venting V 40 Max Note Ins...

Страница 18: ...hing Fireplace Installation ELECTRICAL SUPPLY CONNECTION CAUTION Disconnect the electrical power to the supply circuitbeforeattemptingtocon nect or service this appliance WARNING This appliance when i...

Страница 19: ...bottom of the fireplace base area be sure that the electrical power to the outlet is turned off before proceeding with blower instal lation Failure to do this may result in serious injury Model BK In...

Страница 20: ...tc h W hit e W hit e Bla ck Gr ee n On 11 0 1 15 V A C Blo we r Mo tor Bla ck Bl ac k Bl ac k Of f Figure 29 Location of Wiring Diagram Decal Model May Vary From Illustration Wiring Diagram Decal 6 in...

Страница 21: ...eads and make sure wire routing is not pinched or in a precarious position Correct accordingly 8 Turn on power to duplex outlet if previously turned off per warning in column 1 page 19 9 Plug in blowe...

Страница 22: ...ing Alkaline Battery to Receiver 9 Volt Alkaline Battery Receiver Terminal Wires Battery Clip Figure 35 Mounting Remote Receiver to Bracket Installing 9 Volt Alkaline Battery in Hand Held Remote Contr...

Страница 23: ...or propane LP connection only the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 inches...

Страница 24: ...wer louver door panel by gently pull ing forward 2 Route flexible gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access hole...

Страница 25: ...ply Tank Gas Valve Equipment Shutoff Valve Figure 42 Checking Gas Joints for Natural Gas Fireplace Gas Meter Gas Valve Equipment Shutoff Valve Fireplace Installation Continued Pressure Testing Firepla...

Страница 26: ...and let coolbeforeaccessing orservic ing the unit Figure 44 Removing Top Louver Trim Panel Panel Tabs Top Louver Trim Panel Door Pin Hanger Bracket WARNING Handle glass door panelwithcare Donot strik...

Страница 27: ...Door page 25 to access the logs and burner Assemble the logs and add burner treatments as follows 1 Position the base log onto burner log mounts see Figure 46 Note The cut out on the bot tom should f...

Страница 28: ...P Follow B in the safety information above If you don t smell gas go to the next step 6 The pilot is located by the main burner and should not require accessing for lighting 7 Turn gas control knob co...

Страница 29: ...s Control Knob and Variable Control Knob for Remote Operation On Off Series Model HRC100 Hold the control button on the hand held remote until burner turns on Hold the con trol button again until burn...

Страница 30: ...nlock the keypad on the hand held remote in the MANU or AUTO mode to prevent inadvertent operation i e children operating the hand held remote control etc The keypad is locked in either on or off Pres...

Страница 31: ...es after installation to ensure proper installation and performance Figure 53 shows a typical flame pattern If burner flame pattern differs from that de scribed turn fireplace off see To Turn Off Gas...

Страница 32: ...ed with kit The number 30 is stamped on the sleeve for identification Insert small end of new pilot orifice into barrel and thread until tight with allen wrench 4 Line up notch on pilot hood to positi...

Страница 33: ...proxi mately 25 in lbs see Figure 59 3 Install the identification label enclosed with the gas valve regulator to the valve body where it can easily be seen see Figure 59 Conversion Instructions Contin...

Страница 34: ...arts page 38 for detail on ordering No substitutions maybemade SeeRemoving ReplacingGlassDoor page 25 for instructions for replacing glass door WARNING Do not operate fireplace with the glass door unl...

Страница 35: ...n 3 Gas control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct RE...

Страница 36: ...maged burner 3 Replace gas control 1 Problem will stop after a few hours of operation 1 Turn gas control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from lin...

Страница 37: ...e 33 4 Locate and correct all vent connections see Installation Planning page 11 5 Tighten or replace glass door see Removing Replacing Glass Door page 25 6 Replace faulty components 7 Check for prope...

Страница 38: ...age for parts replaced under warranty Parts Under Warranty Contact authorized retailers of this product If they can not supply original replacement part s call DESA s Customer Service Department at 1...

Страница 39: ...ouvers Only LTC36B Rolled Louver Trim Kit Brushed Brass LTC36P Rolled Louver Trim Kit Platinum WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access for thermostatic operation of...

Страница 40: ...www desatech com 118531 01A 40 Illustrated Parts Breakdown Fireplace Assembly for Model CD36TN M 1 2 8 10 9 1 1 12 3 16 5 6 7 13 19 1 4 1 3 2 4 14 15 17 18 11...

Страница 41: ...g 1 4 114880 01 Heat Deflector 1 5 114875 02 Fireplace Surround 1 6 114876 02 Fireplace Top 1 7 116016 02 Fireplace Top Insulation 1 8 114873 01 Louver Bottom Assembly 1 9 114872 01 Louver Top Assembl...

Страница 42: ...www desatech com 118531 01A 42 Illustrated parts breakdown BURNER ASSEMBLY FOR MODEL CD36TN M 1 2 3 5 20 9 18 11 10 19 12 6 7 17 13 14 16 15 4 8...

Страница 43: ...e LP Gas 1 5 27206 Burner Orifice 44 Natural Gas 1 26482 Burner Orifice 55 Propane LP Gas 1 6 26808 Valve Bracket 1 7 24389 Tube 3 8 Dia x 11 Aluminum 1 8 24360 Pilot Bracket 1 9 14500 Fitting 3 8 MPT...

Страница 44: ...ter MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition beca...

Отзывы: