W
arning
Avoid running on no load or very light load for extended periods.
This can lead to carbon deposits in the combustion chambers and
incomplete combustion of fuel.
17
4 Operation
Running
If one or more of the following faults occur, the generator set will be
switched off automatically:
-
low oil pressure,
-
over temperature coolant,
-
over temperature exhaust,
-
over or under frequency,
-
over or under voltage.
In case of an alternator failure, a warning is generated but the engine
will continue running.
At the remote, if installed, a warning buzzer will sound.
On this panel is a ‘alarm accept’ button
.
Press the button
momentary and the buzzer will be switched off for
a period of 10 minutes.
Keep the button
pressed for more than 3 seconds and the buzzer
will remain off as long as the alarm situation exists.
W
arning
NEVER
switch the main switch (between battery and generator set)
OFF while the engine is running.
Содержание GHX14
Страница 1: ...380502 01 Generator Sets Owner s Manual GHX GLX...
Страница 2: ...ii...
Страница 43: ...41...
Страница 48: ...46 11 Overall dimensions 3 2 1 4 5 B A C D E 13 1 2 4x F G H...
Страница 50: ...48...
Страница 51: ...49...