090433.01
15
Battery Monitor
ENGLISH
• Press the right push button to en-
ter
Battery
mode.
• Adjust the value of the battery ca-
pacity and press both push buttons
simultaneously for at least 3 seconds
to confirm.
t
ip
If the battery is in poor condition (old,
often been discharged and re-charged,
etc.) then enter a lower value then the
battery capacity as stated on the bat-
tery. A battery of 3 years old can have a
capacity of only 80 %.
3.3 Shunt
De supplied shunt is specified for 200 A
/ 100 mV.
If a shunt with a different specification is
installed the value for the shunt must be
adapted.
• Go to
Battery Monitor Setup
see
‘2 Operation’
.
• Press both push buttons simultane-
ously for at least 3 seconds to se-
lect
Battery Monitor Setup
, see
'4 Entering current capacity shunt’
.
• Press the left push button once to se-
lect
Shunt
.
• Press the right push button to en-
ter
Shunt
mode.
• Adjust the value of the shunt and
press both push buttons simultane-
ously for at least 3 seconds to confirm.
Specification
shunt
Value to be set
200 A / 100 mV
200 A
100 A / 100 mV
100 A
80 A / 60 mV
133 A
100 A / 60 mV
167 A
200 A / 60 mV
333 A