6.2.4
Checking the locking device
WARNING!
Risk of injury from a defective locking device!
The locking device prevents undesired lateral movement of the
Smart
Fork
®
on the profile of the fork carriage. Uncontrolled movement of
the VETTER Smart
Fork
®
during transportation could cause the load to
slip and cause serious injuries.
–
Replace damaged locking devices immediately.
–
If the locking device is missing, it must be replaced before start-up.
–
Do not use the VETTER Smart
Fork
®
without a locking device.
1.
Check the open and lock positions of the lever.
2.
Check the locking device for damage and completeness
3.
Remove any dirt from the locking device.
6.2.5
Cleaning the VETTER SmartFork
®
Personnel:
n
Driver of industrial trucks
Protective equipment:
n
Protective work clothing
n
Industrial helmet
n
Protective gloves
n
Safety shoes
Check the following points:
n
Regularly clean the VETTER Smart
Fork
®
.
n
Do not use a high-pressure cleaning device and do not use any aggressive
cleaning products.
n
Clean the fork blade and back/shank with a broom or brush.
n
Clean the protective glass of the cameras and sensors with a soft cloth and
soapy water without applying any pressure.
Maintenance of the VETTER SmartFork
®
Maintenance activities > Cleaning the VETTER SmartFork®