Model: 8996
MINI POCKET
THERMO-ANEMOMETER
WITH COMPASS
OPERATION MANUAL
Страница 1: ...Model 8996 MINI POCKET THERMO ANEMOMETER WITH COMPASS OPERATION MANUAL ...
Страница 2: ...nt and portable easy to use and to get a precision reading Read thoroughly before using the meter the unit was calibrated before shipment There are several models of mini anemo meter and weather meter available please contact with your store for more detail information Windspeed displays real time windspeed Max Windspeed display the Max windspeed Avg Windspeed display 10 sec average windspeed Comp...
Страница 3: ...it 1 1 20 0 60 3937 0 4 38 8 0 8 72 0 0 5 44 7 0 1 99 9 20 50 15 50 5 122 1 8 0 1 2 0 1 0 1 0 1 0 1 0 1 0 1 1 0 1 Range Unit MPS FPM KNT KPH MPH RH BF DP RS RS stands for Resolution o C o F This package contains The meter x 1 Battery x 1 CR 2032 Operation manual Strap Paper box MATERIAL SUPPLIED WBT WCI Windchill Wet Bulb Temp 5 50 20 50 0 1 0 1 ...
Страница 4: ...st time use 2 The low battery symbol appears on LCD 3 The meter can not power on To install the battery 1 Turn off the meter 2 Turn the battery compartment cover in a CLOCKWISE direction to remove it 3 Replace the old battery with one new CR 2032 lithium battery 4 Make sure the battery is in place and the polarity is correct 5 Affix the battery compartment cover by turning it in a COUNTER CLOCKWIS...
Страница 5: ...that you do not plan to use for a month or more Do not leave battery in instrument 4 1 Vane impeller 2 Wind direction indicator 3 LCD display 4 ON OFF and MODE key 5 UNITS key 6 Battery compartment on rear 7 Swivel handle and storage case 8 Lanyard holder 9 Precision thermistor Humidity sensor 10 Tripod mount on the bottom 9 9 10 10 ...
Страница 6: ...of the meter i e the display face to the user Press the key to turn on the meter Auto power off in 5 minutes or press To disable the auto power off before power on pressing key until a n appeared on the screen and then release keys to return to normal mode key for 3 seconds to turn the power off UNIT SELECT MODE Press mode key to change the mode The sequence is Current windspeed Max Windspeed 10 s...
Страница 7: ...lect and enter into Compass mode Point the meter in the direction of travel or target and get a steady compass reading Press and hold UNIT key until Headtailcross appear on LCD com pass reading will then flash three times Release UNIT key and point the meter into the wind until you have a steady compass reading Press and hold UNIT key until Compass reading start flashing It flashes three times and...
Страница 8: ...according to the direction as below drawing each turn takes 15 seconds COMPASS CALIBRATION After 2 turns 30 seconds the LCD show End to indicate the calibration is completed NOTE 1 Calibrate the compass after a new battery is installed 2 To get an accurate compass reading it is suggested to run this simple calibration procedure before use ...
Страница 9: ...of the windmeter Then remove the impeller by twisting the impeller assembly clockwise if you are facing the back of the windmeter to the O position marked on the rear of the rear of the meter Install a new impeller by following these instructions in reverse 3 O L O L VANE REPLACEMENT NOTE The anemometer is very accurate at low and mid range air speeds Constant use at very high speeds such as measu...
Страница 10: ...onse time 60 seconds typical Air RH response time 60 seconds typical LCD update every second Windchill display YES 20 0 50 0º C Dew Point temp display YES 20 0 50 0º C Wet bulb display YES 5 0 50 0º C Compass display YES 0 360 degree Compass accuracy 2 degree LCD size 16 H x 28 W mm Operating temp 15 SOº c Operating RH Humidity 80 Storage temp 20 SOº C Storage RH Humidity 90 Dimension mm 140x45x25...