USER INSTRUCTIONS

ENGLISH

, V1.0

V-LINK 

67601 / 671201 / 672501 / 675501

Содержание V-LINK 671201

Страница 1: ...USER INSTRUCTIONS ENGLISH V1 0 V LINK 67601 671201 672501 675501 ...

Страница 2: ...d H Capacity Serial no engraved B Red LED display I USB port only for charging C Operating panel J Safe Working Load SWL D Manufacturer name K Item no E ON OFF button L Read manual CE F Tare button M Manufacturer name G Hole for shackle ...

Страница 3: ... until the display shows 0 and the red button lights Press 0 to deactivate Peak hold operating multiple dynamometers with wireless display Press and hold MENU until the display shows 1 Use the arrows to choose between menu 1 and 2 Menu 1 Peak hold function Menu 2 Operating multiple Dynamometers See Advanced Settings for complete instruction Tænd Sluk Low battery The battery indicator will flash wh...

Страница 4: ...ation 5 3 4 Overload 5 4 Basic settings 6 5 Menu Advanced settings 7 5 1 Peak hold Menu 1 7 5 2 Operating multiple dynamometers in the same area Menu 2 8 6 FAQ 9 7 Charging 9 8 1 Battery replacement 10 8 2 Regulatory audit calibration 10 9 Maintenance 10 10 Waste Electrical and Electronic Equipment WEEE 10 11 Warranty 11 Thank you for purchasing a V LINK dynamometer Page Installation operation and...

Страница 5: ...ity assurance and the service department provides professional support repair and calibration service Vetec A S Teknikvej 69 DK 5260 Odense S Tlf 45 65919802 post vetec dk www vetec dk 1 1 Important information READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE INSTALLATION AND USE These instructions have been published byVetec A S and are not subject to any guarantee The instructions may be with...

Страница 6: ...ment according to ISO 2081 IP class IP 67 Display Bright LED Digit height 14 mm Digit color Red Operating time 16 20 hours Operation temp From 20 C to 50 C Batteries Build in Li on Charger High quality USB charger Rounded due to increment Operating at low temperatures will decrease the operating time Item no A mm B mm C mm D mm E mm Ø mm Weight Kg 670601 200 00 115 00 117 00 260 00 41 50 31 00 4 4...

Страница 7: ...under optimal conditions Number of channels 99 Standard frequency 869 750 Mhz Communication form Duplex RF output power 10 mW IP class IP65 Operating time 16 20 hours Operating at lowtemperatureswill decrease the operating time Operating temp From 20 C to 50 C Batteries Build in Li on Charger Standard USB charger as used for the V LINK Dimensions H145 x L88 x W23 mm Weight 0 15 kg Varenr WRDTX01 W...

Страница 8: ...national standards Fe Zn12 A surface treatment according to ISO 2081 During installation ensure Adequate resistance of the load line s anchorage points in relation to the force that will be applied The compatibility of anchoring accessories in both ends of the dynamometer and compliance with applicable regulations Lock the shackles by tightening their pin to the limit and make sure that the safety...

Страница 9: ...th For optimal maintenance apply a thin layer of light oil e g WD 40 In case of an overload it is imperative to completely release the stress on the dynamometer and conduct the following overload test Overload test Turn the dynamometer off and on If it indicates a value much higher or lower than the usual starting value it has been permanently damaged In this case it is imperative to have it check...

Страница 10: ...function press and hold 0 until the display shows 0 and the red button lights Press 0 to deactivate The tare function will automatically de activate when the dynamometer is turned off The dynamometer will not automatically turn off if not used The tare function will automatically deactivate when the dynamometer is turned off The battery indicator lights blue when charging The blue light will turn ...

Страница 11: ... on Press ENTER to activate Peak hold The display now shows 1 Press RETURN to see the untared measurement Tryk RETURN for at gå tilbage til måling When peak hold is activated the second button lights up red Lift a load and the display will freeze at the highest measurement recorded Press and hold 0 until the display shows 0 Lift a load The display will freeze at the highest measure ment recorded R...

Страница 12: ...ault channel The first digit is blinking which means that it can be changed using the arrows Choose between 99 frequencies Select a channel by pressing ENTER Press RETURN to go back to weighing Menu 2 is used when operating multiple dynamometers with wireless displays in the same area To avoid interference each set of dynamometer and wireless display can be set to operate on its own channel In men...

Страница 13: ... it can be changed using the arrows Select the channel that corresponds to the channel of the V LINK you want to operate Press ENTER to select channel Press RETURN to go back to weighing The channel settings will remain when the dynamometer and display are turned off The channel is as default set as the last two digits of your V LINK serial number Anomalies Possible causes Corrective actions The d...

Страница 14: ...tor blinks when it needs to be replaced It is recommended to purchase the battery replacement kit that includes a Li on battery and a new foil Remove the foil Use a suitable screwdriver to remove the battery cover Replace the battery with a new battery Put the battery cover back on and tighten the screws so that the cover is flush with the edge of the battery case Ensuring that it is is in correct...

Страница 15: ...e unit The following faults are not covered by the warranty Faults resulting from normal wear and tear Parts of a consumable nature Products that have been subject to unauthorized modifications Faults resulting from incorrect installation or use Damp or water damage exceeding the IP classification A V LINK must not be thrown away with general rubbish Any disposal of the device must be carried out ...