![Vestil DCR-880-H Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/vestil/dcr-880-h/dcr-880-h_manual_1009673014.webp)
Rev. 6/30/2020
DCR-880, MANUAL
Copyright 2020 Vestil Manufacturing Corp. Page 14 of 25
12VDC modular power unit electrical circuit diagram
Limit switch or jumper
wire used where
applicable.
Exploded view of DC manifold assembly (item no. 24 on p.14)
Item
Part no.
Description
Qty.
31
568-015-BN70 O-ring
1
32
568-011-BN70 O-ring
1
33
99-153-058
Valve, cartridge, normally closed
1
34
99-034-010
Coil with weather-tite plug
1
35
99-153-006
Valve, pressure relief
1
36
568-334-BN70 O-ring
1
37
99-531-005
Filter
1
38
99-153-038
Flow control, 1.0GPM
1
39
01-127-010
Manifold
1
40
6801-06-06-NWO MJ-MAORB 90 degree
1
41
99-153-011
Valve, check
1
NOTES:
Units built after Dec. 1, 2018, receive 2
nd
generation modular power units (MPU-GEN2).
Overcurrent & short-circuit protection and system disconnect must be provided.
*
Units built after Dec. 1, 2018, receive 2
nd
generation
modular power units (MPU-GEN2).