Vestil CBFC-DC Скачать руководство пользователя страница 1

TABLE OF CONTENTS

  

Rev. 4/22/2022 

CBFC, MANUAL 

TABLE OF CONTENTS

 

Copyright 2022 Vestil Manufacturing Co. 

Page 

1

 of 

12

 

 

                                              

 

 

 

 

 

CBFC-DC Powered Lift Counterbalanced Floor Cranes 

 

 

 

 

Receiving Instructions  

  After delivery,  remove the packaging from the product. Inspect the product closely to determine 

whether it sustained damage during transport. If damage is discovered, record a complete description 

of it on the bill of lading. If the product is undamaged, discard the packaging.

 

 

NOTE:

 

The end-user is solely responsible for confirming that product design, use, and maintenance 

comply with laws, regulations, codes, and mandatory standards applied where the product is used.

 

 

Technical Service & Replacement Parts  

  For answers to questions not addressed in these instructions and to order replacement parts, labels, 

and accessories, call our Technical Service and Parts Department at (260) 665-7586. The department 

can also be contacted online at 

https://www.vestil.com/page-parts-request.php

.

 

 

Electronic Copies of Instruction Manuals 

Additional copies of this instruction manual may be downloaded from 

https://www.vestil.com/page-

manuals.php

.

 

 

 

V

ESTIL 

M

ANUFACTURING 

C

ORP

2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 

Telephone: (260) 665-7586  -or-  Toll Free (800) 348-0868 

Fax: (260) 665-1339 

www.vestil.com

  

        

info@vestil.com

 

 

 

 

Table of Contents 

Page 

Signal Words

….………………………………………………………………………………………………….   

2

 

Safety Instructions

……………………………………………..……………………………...……………… 

2

 

CBFC-500 & CBFC-1000 Exploded View & Bill of Materials

…………………..………………………  

3

 

CBFC-500 Rated Loads for Specified Boom Lengths

…….……………………………………………… 

4

 

CBFC-1000 Rated Loads for Specified Boom Lengths

 …….……………………….……….………….  

5

 

CBFC-2000 Exploded View & Bill of Materials

……………….…..………………………..……………  

6

 

CBFC-2000 Rated Loads for Specified Boom Lengths

…………..………………………....…………… 

7

 

Raising and Lowering the Boom

…………….…………..………………………………………..………… 

8

 

Using the Crane

………………………………………………………………………...…………………….… 

8

 

Air Purging Procedure

………………………………………………………………………………………  

9

 

Boom Length Adjustment

…………………..………………………………………………………………… 

9

 

Record of Satisfactory Condition

…………………………………………………………………………  

9

 

Inspections & Maintenance

………………………………………………………………………………….  

9

 - 

10

 

Troubleshooting

…………………………………………………………………………………………………  

10

 - 

11

 

Labeling Diagram

……...……………………………………..…………………………………………..…… 

11

 

Limited Warranty

…...…………………………………………………………………………………………… 

12

 

 

NOTE:

  A copy of the 

MPU-DC Gen2 manual is 

also necessary. 

Содержание CBFC-DC

Страница 1: ...s Department at 260 665 7586 The department can also be contacted online at https www vestil com page parts request php Electronic Copies of Instruction Manuals Additional copies of this instruction m...

Страница 2: ...ALWAYS observe the boom while raising or lowering a load Watch for binding or jerky movement Listen for unusual noises Tag the unit Out of Service and do not use it if you observe anything abnormal D...

Страница 3: ...9 024 003 GUARD COVER ENDCAP PLUG 2 24 65077 COTTER PIN ZINC PLATED 1 8 X 1 1 4 3 9 11209 1 2 13 X 1 1 2 LG HHCS ASTM A307 GRADE A ZINC PLATED 2 25 99 160 097 MODULAR POWER UNIT GEN II 2 Pushbuttons E...

Страница 4: ...ted load 391 4 inches 500 lb 227 3kg 511 4 inches 400 lb 181 8kg 631 4 inches 300 lb 136 4kg 1in 2 54cm 1kg 2 2 lb SPECIFICATIONS A specifications document for CBFC 500 DC floor cranes is available on...

Страница 5: ...ted load 391 4 inches 1000 lb 454 5kg 511 4 inches 700 lb 318 2kg 631 4 inches 500 lb 227 3kg 1in 2 54cm 1kg 2 2 lb SPECIFICATIONS A specifications document for CBFC 1000 DC floor cranes is available...

Страница 6: ...OWER UNIT GEN II DISPLAY ONLY 1 9 11209 1 2 13 X 1 1 2 LG HHCS ASTM A307 GRADE A ZINC PLATED 2 26 33096 FLAT WASHER LOW CARBON PLAIN FINISH 1 x 2 OD 2 10 33011 FLAT WASHER USS PLAIN FINISH 1 2 2 27 33...

Страница 7: ...um rated load 391 4 in 2000 lb 909 1kg 511 4 in 1500 lb 681 8kg 631 4 in 1000 lb 454 5kg 1in 2 54cm 1kg 2 2 lb SPECIFICATIONS A specifications document for CBFC 2000 DC floor cranes is available onlin...

Страница 8: ...ld controller 4 Attach the rigging to the load hook The floor crane must be on a sound level and dry surface Before raising the boom be sure that the load hook is centered above the load If the hook i...

Страница 9: ...condition Replace parts that are not in satisfactory condition before returning the unit to service Never make temporary repairs of damaged or missing parts Only use manufacturer approved replacement...

Страница 10: ...d be square and rigid Examine welds Make sure all welds are intact and are free of rust and corrosion 6 Labels Check all labels applied to the product The crane must be labeled as shown in the LABELIN...

Страница 11: ...ove valve and inspect for debris or non operating spool LABELING DIAGRAM Label content and location are subject to change so your product might not be labeled exactly as shown Compare the diagram belo...

Страница 12: ...aulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How...

Отзывы: