IMPORTANT
Before attempting to carry out any work on our units, all accompanying
documentation including warning labels on the unit must be referenced.
Should it be necessary to remove any component ensure that these are
secured into position once reinstalled. It is critical that after any
maintenance work has been conducted that all components removed
/replaced be refitted correctly by a competent engineer.
POLO100/150
Bathroom Extract Fans
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: [email protected] web: www.ves.co.uk
Original Instructions : Installation, Operation & Maintenance Manual
ID Ref 846
C
0
8
/
14
Original Instructions : Installation, Operation & Maintenance Manual
Original Instructions : Installation, Operation & Maintenance Manual
This manual must be read in full before Installation, Operation and
Maintenance of the units supplied. Please ensure that this document is
passed to the end user. This manual forms an integral part of the product
and should be kept for the working life of the product. Additional copies of
this and supporting documents are available by contacting VES or by
visiting www.ves.co.uk and following the 'Download O & M's' link.
IMPORTANT
The following symbols used within this document refer to potential dangers
or advice for safe operation
Indicates hazards associated with electric current and high
voltages
Indicates hazards that require safety advice for personnel
and/or potential unit/property damage
Indicates important information
POLO fans are suitable for installation in Zone 2 and outside the zoning area
(see below)
.
IMPORTANT
EXCEPT all HM/AT & AS/HM/AT models which MUST be
mounted outside the zoning area
All POLO fans must be sited and installed in accordance with current IEE
Regulations BS7671 and the appropriate Building Regulations.
POLO fans are suitable for wall or ceiling
mounting except the PC (pull cord) model which is suitable for wall
mounting only.
The fan should be installed in conjunction with an appropriate mounting kit
and consideration must be given to ensure that access to all moving parts of
the fan are restricted when the fan is in use.
Unit Description
The POLO series is range of axial fans suitable for bathroom extract
applications; for full unit details please see the unit specification later in the
document.
Immediately upon receipt of your POLO fan, check there is no damage to
the fan, and that the four fixing screws and matching wall plugs are
included within the ancillary bag.
In the event of any damage having occurred or if any item is found to be
missing, it is essential to inform VES Andover Ltd. within 7 days of delivery
quoting sales order number and the unit type. After this period, VES would
be unable to accept any claim for damaged or missing goods.
Part Number
Description
POLO100 or 150 ............................ Standard extract fan
POLO100 or 150/PC .......................Fan c/w pull chord
POLO100 or 150/AT ....................... Fan c/w adjustable timer
POLO100 or 150/HM/AT................. Fan c/w adjustable humidistat & timer
POLO100 or 150/PIR/AT..................Fan c/w PIR sensor & timer
POLO100 or 150/AS ....................... Fan c/w automatic shutter
POLO100 or 150/AS/AT ..................Fan c/w auto shutter & timer
POLO100 or 150/AS/HM/AT............Fan c/w auto shutter, humidistat & timer
POLO100 or 150/AS/PIR/AT............ Fan c/w auto shutter, PIR sensor & timer
Dimensions
A
B
C
D
Ø
(mm)
POLO100
156
154
29
55
98
POLO150
209
208
31
69
148
A
B
C
D
Ø
1
zone
0
zone
2
zone
2
zone
2
zone
600mm
600mm
600mm
2250mm