b)

 

R48-2000 and R48-2000H:  At 25°C ≤ 53dB(A) with fan in high speed.  Measurement made at 0.6m 
distance in front of rectifier and at same horizontal line of the middle of rectifier. 

 

EMI/RFI Suppression: 

a)

 

Rectifiers operating in an approved rectifier Mounting Shelf conform to the requirements of FCC 
rules Part 15, Subpart B, Class B for Radiated and Conducted emissions limits. 

b)

 

Rectifiers operating in an approved rectifier Mounting Shelf conform to the requirements of 
European Norm, EN55022, Class B for Radiated and Conducted emissions limits. 

Compliance Information 

 

EMC:  ETSI EN 300 386 class B, FCC CFR 47 Part 15 class B, Telcordia GR-1089-CORE class B. 

 

Safety:  IEC 60950, EN 60950, UL 60950. 

Standard Features 

 

Type of Power Conversion Circuit:  High frequency. 

 

Constant Voltage Mode:  For any initial output voltage setting from 42 to 58 volts, output voltage 
remains constant regardless of load.  This is the normal operating condition, in which loads are being 
supplied and batteries are float charged.  Rectifiers operate in the Constant Voltage Mode unless load 
increases to the point where the product of load current and output voltage is approximately 2000W. 

 

Constant Power Mode:  As load increases above approximately 2000W (non-adjustable), output current 
continues to increase, but output voltage decreases as required to maintain constant output power.  
Rectifiers operate in the Constant Power Mode unless load continues to increase to the point where the 
current limit setting is reached. 

 

Constant Current Mode:  If load increases to the current limit setting, output voltage decreases linearly 
to maintain output current at the current limit setting. 

 

Input Protection: 

a)

 

Input Over/Under Voltage Protection:  The rectifier will shut down at low or high voltage input; based 
on the following voltage levels: 

1.

 

Low voltage disable point 80 V, ±5 V; hysteresis is 10 - 20 VAC for restart. 

2.

 

High voltage disable point 305 V, ±5 V; hysteresis is 10 - 15 VAC for restart. 

b)

 

Between 85 V and 176 V the output power will be derated linearly based on the input voltage as 
follows: 

1.

 

At input voltage of 85 V with output >48 V, max output power is 800 W. 

2.

 

At input voltage of 120 V with output >48 V, max output power is 1262 W. 

3.

 

At input voltage of 154 V with output >48 V, max output power is 1700 W. 

4.

 

At input voltage of 176 V and output >48 V, max output power is 2000 W. 

Содержание NetSure R48-2000

Страница 1: ...NetSure Rectifier Module User Manual UM1R482000e 11BU1360YY Revision J Specification Number 1R482000 1R482000e 1R482000H Model Number R48 2000 R48 2000e R48 2000H...

Страница 2: ...nd materials to be used in performing procedures not specifically described in this document This document may contain confidential and or proprietary information of Vertiv Group Corporation and its r...

Страница 3: ...Overview 7 Specifications 7 DC Output Ratings 7 AC Input Ratings 11 Environmental Ratings 19 Compliance Information 20 Standard Features 20 Mechanical Specifications 23 Operation 24 AC Input Protectio...

Страница 4: ...avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable standards OSHA ALERT...

Страница 5: ...pable of producing fatal electrical shock DC Output and Battery Voltages DANGER This system produces DC power and may have a battery source connected to it Although the DC voltage is not hazardously h...

Страница 6: ...ary Read and follow wrist strap manufacturer s instructions outlining use of a specific wrist strap 3 Do not touch traces or components on equipment containing static sensitive components Handle equip...

Страница 7: ...Mode unless load increases to the point where the product of load current and output voltage is approximately 2000W Constant Power Mode As load increases above approximately 2000W non adjustable outpu...

Страница 8: ...varies with changes in input voltage and output voltage It uses an advanced power limitation method The lower input threshold is 85 VAC The rectifier can provide its maximum rated power 2000W as long...

Страница 9: ...00 and R48 2000H or 55 C 131 F R48 2000e the rectifier will not shut down Rather the rectifier limits its maximum output power to maintain the temperature of the power conversion circuit within design...

Страница 10: ...2000 and R48 2000H or 55 C 131 F R48 2000e and 80 C 176 F will result in output power decrease Operation above 80 C 176 F is considered abnormal and should be used on a temporary1 basis only 1 Tempora...

Страница 11: ...ut and 20 to 70 of rated load 3 R48 2000 1R482000 and R48 2000H 1R482000H Psophometric noise is 1 mV at 5 to 100 of rated load 4 R48 2000e 1R482000e Psophometric noise is 2 mV typical at 20 to 70 of r...

Страница 12: ...5 1980 5 99 80 94 90 344 98 110 10 32 2149 8 2139 5 99 52 94 58 395 71 120 10 36 2151 8 2147 5 99 80 94 22 423 81 240 0 0 38 106 6 32 5 30 50 110 89 25 2 13 509 3 494 5 97 10 95 37 78 10 50 4 15 996...

Страница 13: ...5 99 85 94 21 424 15 240 0 0 33 74 3 26 0 35 00 88 72 25 2 11 505 1 494 5 97 90 95 42 77 24 50 4 13 991 9 982 0 99 00 96 21 126 91 75 6 15 1474 3 1467 5 99 54 95 97 201 88 100 8 24 1975 3 1970 0 99 73...

Страница 14: ...0 99 94 89 93 766 53 240 0 0 33 77 8 27 7 35 60 94 52 25 2 23 534 1 525 0 98 30 89 70 184 52 50 4 29 1028 8 1026 0 99 73 91 90 283 66 75 6 38 1529 5 1529 0 99 97 91 90 422 83 100 8 58 2055 2 2055 0 99...

Страница 15: ...2 99 96 89 75 780 85 240 0 0 29 65 9 27 41 00 92 13 25 2 22 531 1 525 98 86 89 86 181 62 50 4 29 1028 7 1027 99 83 91 88 284 42 75 6 37 1531 3 1531 99 98 91 85 425 70 100 8 57 2057 2 2057 99 99 91 20...

Страница 16: ...99 96 91 42 645 48 240 0 0 362 86 5 36 5 42 20 124 54 25 2 20 526 5 516 0 98 00 91 47 150 24 50 4 26 1018 4 1015 0 99 67 93 11 238 56 75 6 31 1513 6 1513 0 99 96 93 09 356 94 100 8 46 2029 2 2029 0 9...

Страница 17: ...0 99 97 91 45 642 57 240 0 0 32 75 0 36 0 48 00 122 84 25 2 18 523 3 516 5 98 70 91 36 152 32 50 4 23 1016 2 1014 0 99 78 93 16 236 62 75 6 30 1513 3 1513 0 99 98 93 03 359 86 100 8 46 2026 2 2026 0 9...

Страница 18: ...Vertiv NetSure Rectifier Module User Manual UM1R482000e 11BU1360YY Rev J 18 Figure 7 Efficiency Curve R48 2000e 1R482000e Figure 8 Efficiency Curve R48 2000 1R482000...

Страница 19: ...arth Capable of withstanding surges per ANSI IEEE C 62 41 1980 Category B3 across the input terminals NOTE This level of protection is a widely used standard for telecommunications power equipment As...

Страница 20: ...ltage Mode unless load increases to the point where the product of load current and output voltage is approximately 2000W Constant Power Mode As load increases above approximately 2000W non adjustable...

Страница 21: ...value before the HVSD restart timer expires the rectifier shuts down and locks out Manual restart is then required by turning power to the rectifier off or by removing the rectifier waiting until the...

Страница 22: ...ized by the controller the output voltage is updated to the setting programmed into the controller If communications with an SCU controller is lost rectifier output voltage goes to a default value pro...

Страница 23: ...n Fail Protection Alarms such as Input Voltage Protection Inner DC Bus Voltage Protection High Temperature Protection Thermal Derating AC Derating AC Fail Imbalance Output Current Address Code Date So...

Страница 24: ...iption There are three 3 indicators located on the rectifier s front panel The functions of these indicators are as shown in Table 14 NOTE DC voltage must be present at the rectifier output terminals...

Страница 25: ...internal output fuse open Rectifier addresses contradictory Flashing Fan not operating rectifier module shuts down Installing Rectifiers The rectifier is hot swappable It can be installed with the sy...

Страница 26: ...tation for instructions Figure 11 Installing a Rectifier TROUBLESHOOTING AND REPAIR Troubleshooting Rectifier Current Sharing Imbalance When multiple rectifiers are operating in parallel and the curre...

Страница 27: ...y object that may be blocking the inlet or outlet Ambient temperature too high or rectifier inlet too close to a heat source lower the ambient temperature or relocate the heat source Rectifier in ECO...

Страница 28: ...n the underside of the rectifier This unlocks the rectifier from the shelf Refer to Figure 11 for latch mechanism illustration 3 Slide the rectifier out by pulling forwards 4 Place the replacement rec...

Страница 29: ...the remainder of this procedure 4 On this rectifier remove the front panel by removing the screws securing the front panel to the chassis and by unplugging the fan from the printed circuit card 5 For...

Страница 30: ...Vertiv NetSure Rectifier Module User Manual UM1R482000e 11BU1360YY Rev J 30 Figure 12 Rectifier Fan Replacement...

Страница 31: ...Vertiv NetSure Rectifier Module User Manual UM1R482000e 11BU1360YY Rev J 31 This page is intentionally blank...

Страница 32: ...VertivCo com Vertiv Headquarters 1050 Dearborn Drive Columbus OH 43085 USA UM1R482000e 11BU1360YY RJ 08 17...

Отзывы: