3.3 Display-panel Indicators

NOTE: The display automatically powers-off to conserve power. However, the display remains on when
there is a warning or fault to call attention to the event.

Figure 3.2 LCD Display

ITEM

DESCRIPTION

1

Battery mode when lit.

2

Replace battery warning when lit. See

Warnings

on page 14, for more details

3

AC-mode:

On solid = Normal mode.

Flashing = Automatic Voltage Regulation mode

4

Output-overload warning when flashing. See

Warnings

on page 14, for more details

5

Site-wiring fault warning when lit. See

Warnings

on page 14, for more details

6

Output-load level graph in 25% increments

7

Numeric display of UPS operational parameters:

VAC = input/output voltage

Hz = input/output frequency

KW = output power

MIN = estimated battery back-up time

8

Fault when lit. Fault codes indicated:

E01

E02

E03

E04

E05

E06

See

Faults

on page 14, for more details

9

Battery-capacity graph in 25% increments

10

Battery-mode alarm muted when lit. See

Audible-tone Indicators

on page 14, for more details

Table 3.2 Display Icons and Indicators

Vertiv

| Liebert® PSA5™ Installer/User Guide |

13

Содержание Liebert PSA5

Страница 1: ...Liebert PSA5 Installer User Guide...

Страница 2: ...any installation or operational issues with your product check the pertinent section of this manual to see if the issue can be resolved by following outlined procedures For additional assistance visi...

Страница 3: ...ging Ports 10 2 4 5 Connecting AC Input 10 3 Operation 11 3 1 Modes of Operation 11 3 1 1 Off Mode 11 3 1 2 On Normal Mode 11 3 1 3 On Automatic Voltage Regulation AVR Mode 11 3 1 4 On Battery Mode 11...

Страница 4: ...Vertiv Liebert PSA5 Installer User Guide 4...

Страница 5: ...ed during the installation and maintenance of the UPS and batteries Read this manual thoroughly and the safety and regulatory information available at https www vertivco com ComplianceRegulatoryInfo b...

Страница 6: ...Vertiv Liebert PSA5 Installer User Guide 6 This page intentionally left blank...

Страница 7: ...t PSA5 provides the run time to save work in process With the Liebert MultiLink shutdown software you can receive remote alerts and have unattended orderly shutdown of your systems 1 1 Available Model...

Страница 8: ...y 5 USB charging ports 5 V 2 1 A max combined 6 Surge protected only receptacles 7 Battery backed and surge protected receptacles 8 USB communication port Type B 9 RJ11 45 connectors for phone fax mod...

Страница 9: ...tions Place it in an area of unrestricted air flow around the unit away from water flammable liquids gases corrosives and conductive contaminants Avoid direct sunlight The socket outlet should be near...

Страница 10: ...tion of the UPS To use this feature plug the provided USB cable into USB Type B port located on the rear panel of the UPS and the other end into an open USB port on your computer 2 4 4 USB Charging Po...

Страница 11: ...cts the low voltage and allows the battery backed up outlets to be on with the normal expected voltage The internal batteries are charging NOTE The surge only outlets will have the abnormally low inpu...

Страница 12: ...Self test mode Press quickly to wake the display 2 Silence Battery mode Alarm button Press and hold for 2 seconds during On Battery mode to mute the battery alarm beep Press quickly to wake the displ...

Страница 13: ...ng See Warnings on page 14 for more details 5 Site wiring fault warning when lit See Warnings on page 14 for more details 6 Output load level graph in 25 increments 7 Numeric display of UPS operationa...

Страница 14: ...s every 30 seconds The battery is weak or damaged Charge the UPS battery for at least 12 hours or replace the battery see Battery Replacement on page 18 Table 3 4 Warning Indicators and Actions 3 6 Fa...

Страница 15: ...3 8 Normal Shut down 1 Press and hold the power button for 1 second The outlets are turned off 2 Disconnect AC input power 3 Remove the battery cover and disconnect the battery connector 3 9 Full Shu...

Страница 16: ...Vertiv Liebert PSA5 Installer User Guide 16 This page intentionally left blank...

Страница 17: ...ny objects into the ventilation holes or other openings of the UPS Do not place the UPS power cord where it might be damaged 4 2 Battery Charging The batteries are valve regulated non spill able lead...

Страница 18: ...lling the two pieces apart see Figure 4 1 below Figure 4 1 Removing cover and disconnecting battery 4 Slide out the existing battery and disconnect bottom top half of the connector cable from the two...

Страница 19: ...asurement Tolerance 5 High Line Normal Mode to Battery Mode 143 VAC High Line Battery Mode to Normal Mode 138 VAC Low line AVR Mode to Normal Mode 110 VAC Low line Normal Mode to AVR Mode 105 VAC Low...

Страница 20: ...Model Leoch DJW12 7 0 CSB GP1272 Leoch DJW12 9 0 CSB HR1234W or UPS12460 Vertiv PSA5 24VBATTKIT Leoch DJW12 9 0 CSB HR1234W or UPS12460 Battery Quantity x VDC x Ah 1 x 12V x 7 0 Ah 1 x 12V x 9 0Ah 2...

Страница 21: ...3 40 14 10 10 15 50 8 8 7 11 60 7 5 5 8 70 5 4 5 4 6 75 4 2 3 2 3 6 4 5 80 4 3 3 5 4 90 3 2 5 2 5 3 5 100 2 2 2 3 Note Run times in this table are approximate They are based upon new fully charged sta...

Страница 22: ...Vertiv Liebert PSA5 Installer User Guide 22 This page intentionally left blank...

Страница 23: ...unter with your Liebert product Please call or e mail us Technical support e liebert upstech vertivco com p 1 800 222 5877 menu option 1 Monitoring support e liebert monitoring vertivco com p 1 800 22...

Страница 24: ...Vertiv Liebert PSA5 Installer User Guide 24 This page intentionally left blank...

Страница 25: ......

Страница 26: ...logos referred to are trade names trademarks or registered trademarks of their respective owners While everyprecaution has been taken to ensure accuracyand completeness herein VertivCo assumes no resp...

Отзывы: