Vertiv Knurr DIS Скачать руководство пользователя страница 1

Vertiv Knürr DIS Load Meter 

Module with Remote Monitoring – 

 

Power Distribution Units

Vertiv Knürr DIS 

Strommessmodul mit 

Fernüberwachung 

-  

Stromverteilungseinheiten

Vertiv Knürr DIS Module de 

mesure de courant avec contrôle 

à distance -  

Unités de distribution 

de courant

Operating Instructions / Bedienungsanleitung / Notice d’utilisation

Содержание Knurr DIS

Страница 1: ...Distribution Units Vertiv Kn rr DIS Strommessmodul mit Fern berwachung Stromverteilungseinheiten Vertiv Kn rr DIS Module de mesure de courant avec contr le distance Unit s de distribution de courant...

Страница 2: ...oning 3 1 Network connection via DHCP 6 3 2 Network connection via static IP address 7 Operation 4 1 Access via the network 9 4 2 Setting limit values 10 4 3 Using the meter display 12 4 4 Setting 15...

Страница 3: ...f hrten Informationen haftbar gemacht werden Wir bernehmen im Speziellen keinerlei Haftung f r Sch den die durch die falsche Verwendung oder Fehlbedienung entstehen Benutzen Sie auch die anderen Dokum...

Страница 4: ...es peuvent tre affich es sur l cran LCD du PDU ou sur un mode distance Divers seuils peuvent tre param tr s Ils indiquent l utilisateur le statut du PDU localement ou distance Fonctions des touches To...

Страница 5: ...r alarm will automatically activate the display Technical data Measured values Current per phase Voltage per phase Apparent power Effective power Energy consumption Power factor Frequency Power consum...

Страница 6: ...configuration of DHCP remains To convert permanently to a static IP address the software settings must be changed accordingly Chapter 3 2 Installation et mise en service Raccordementaur seauvia DHCP...

Страница 7: ...der eines Hadware Reset ber Taste A2 gedr ckt so wechselt die PDU vor bergehend auf eine stati sche IP Adresse 192 168 0 1 Raccordementaur seauvia une adresse IP statique Demandez les points suivants...

Страница 8: ...administrators Installation and Commissioning Cliquez sur le menu SYSTEMS SYST MES Connectez vous au module de mesure du cou rant en tant qu administrateur Saisissez votre nom d utilisateur et le mot...

Страница 9: ...can see all pages and can edit all settings the standard password for administrators is admin user Users can see the Summary and Info pages and can define and edit the limit values in the settings Acc...

Страница 10: ...PDU has more than a single phase The limit value defines the maximum permissible current variance between the phases Settings for the power limit value parameters Enter the following current paramete...

Страница 11: ...A4 Display the corresponding input A5 Attribute current voltage output A6 Measured value A7 Network connection A8 Serial connection If a PDU has more than one input cable you can switch between the di...

Страница 12: ...nergieg B11 Leistungsfaktor Hinweis Falls die Eingangsspannung der PDU unter dem Alarmniveau liegt k nnten die angeschlossene Ausr stung und die PDU Schaden nehmen In diesem Fall muss die Last umgehen...

Страница 13: ...iv Kn rr DIS Load Meter Module with Remote Monitoring Power Distribution Units 03 300 999 8 I ECR No 18618 I 10 18 Farben auf der Anzeige Colors on the display Couleurs de l affichage Betrieb Operatio...

Страница 14: ...1 Click on Systems Log in as an administrator Select PDU Information Enter the name and location of the PDU The designations with description and location may not exceed 15 characters Click on Submit...

Страница 15: ...ystems Log in as an administrator Select the tab Syslog Enter up to four IP addresses and click on the activation checkbox next to the system IP addresses for those from which you want the meter unit...

Страница 16: ...P Agenten im Netzwerk senden kann 4 5 Betrieb Operation Exploitation SNMP If SNMP Simple Network Management Protocol is active messages can be sent from the PDU to SNMP agents in the network and recei...

Страница 17: ...s Log in as an administrator Select the tab SNMP Access Activate SNMP v1 v2 or SNMP v3 Set up to four NMS network management host in the network for SNMP v1 v2 Set up to 10 network management hosts in...

Страница 18: ...ost Click on Submit to save the entries Set the values for the repeating trap settings the description is in the table Pic I Click on Submit to save the entries Send a test trap to check the SNMP sett...

Страница 19: ...For NTP server settings check the activation checkbox Enter the NTP server references Click on Submit to save the entries If required activate the DST settings for your location Daylight Saving Time...

Страница 20: ...id commands for a topic related info command line pducli help topic name For help or a special command related info command line pducli help command name 20 Vertiv Vertiv Kn rr DIS Load Meter Module w...

Страница 21: ...Click on Systems Log in as an administrator Select the tab Modbus Activate the Modbus option Enter the Modbus address PDU supports only the slave function The valid range is between 1 247 Select the...

Страница 22: ...one register Registers that are incompatible with the parameters are answered with a Modbus error code Up to 62 parameters 124 registers can be transmitted in a single transmission sequence Error dete...

Страница 23: ...23 Vertiv Vertiv Kn rr DIS Load Meter Module with Remote Monitoring Power Distribution Units 03 300 999 8 I ECR No 18618 I 10 18 S...

Страница 24: ...24 Vertiv Vertiv Kn rr DIS Load Meter Module with Remote Monitoring Power Distribution Units 03 300 999 8 I ECR No 18618 I 10 18 Betrieb Operation Exploitation T...

Страница 25: ...tab C3 Support C1 Informations syst me Num ro d article Num ro de s rie Date de fabrication AAAA MM JJ Description du produit Version mat rielle Version actuelle install e du firmware Version actuell...

Страница 26: ...date Reset options Restart and restore factory settings Restore Cliquez sur Browse Navigation et naviguez jusqu au fichier MKAPP_Vx x dl Cliquez sur Submit Valider pour d marrer la mise jour du firmwa...

Страница 27: ...n Systems Log in as an administrator Select the tab StartUp Reset Select the factory reset button and click on Submit to save the setting HTML PDU Reset Interface Web Assurez vous d avoir acc s au PDU...

Страница 28: ...not active see 3 1 MAC MAC address for the PDU IP IP address for the PDU If DHCP is OFF an internally defined static address if DHCP is ON an IP address of the DHCP server Subnet mask Gateway DNS Info...

Страница 29: ...Co All other names and logos referred to are trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracy and completeness herei...