background image

VXR-7000U

K66VXR-7000U_Alignment.doc

1

VXR-7000U Alignment

The VXR-7000 is carefully aligned at the factory for the specified performance across the entire
operating frequency range. Realignment should therefore not be necessary except in the event of a
component failure. All component replacement and service should be performed only by an authorized
Yaesu/Vertex representative, or the warranty policy may be void.

The following procedures cover the sometimes critical and tedious adjustments that are not normally
required once the repeater has left the factory. However, if damage occurs and some parts
subsequently are placed, realignment may be required. If a sudden problem occurs during normal
operation, it is likely due to component failure; realignment should not be done until after the faulty
component has been replaced.

We recommend that servicing be performed only by authorized Yaesu/Vertex service technicians who
are experienced with the circuitry and fully equipped for repair and alignment. Therefore, if a fault is
suspected, contact the dealer from whom the repeater was purchased for instructions regarding repair.
Authorized Yaesu/Vertex service technicians realign all circuits and make complete performance
checks to ensure compliance with factory specifications after replacing any faulty components.

Those who do undertake any of the following alignments are cautioned to proceed at their own risk.
Problems caused by unauthorized attempts at realignment are not covered by the warranty policy.
Also, Yaesu/Vertex reserves the right to change circuits and alignment procedures in the interest of
improved performance, without notifying owners.

Under no circumstances should any alignment be attempted unless the normal function and operation
of the repeater are clearly understood, the cause of the malfunction has been clearly pinpointed and
any faulty components replaced, and realignment determined to be absolutely necessary.

The following test equipment (and thorough familiarity with its correct use) is necessary for complete
realignment. Correction of problems caused by misalignment resulting from use of improper test
equipment is not covered under the warranty policy. While most steps do not require all of the
equipment listed, the interactions of some adjustments may require that more complex adjustments be
performed afterwards.

Do not attempt to perform only a single step unless it is clearly isolated electrically from all other
steps. Have all test equipment ready before beginning, and follow all of the steps in a section in the
order presented.

Required Test Equipment

r

 

RF Signal Generator with calibrated output level at 1,000 MHz

r

 

Deviation Meter (linear detector)

r

 

In-line Wattmeter with 5% accuracy at 1,000 MHz

r

 

50 

 RF Dummy Load with power rating 100W at 1,000MHz

r

 

 AF Dummy Load

r

 

Frequency Counter with 0.2ppm accuracy at 1,000MHz

r

 

AF Signal Generator

r

 

AC Voltmeter

r

 

DC Voltmeter: High input impedance

r

 

VHF Sampling Coupler

r

 

SINAD Meter

Содержание VXR-7000

Страница 1: ...proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Yaesu Vertex reserves the right to change circuits and alignment procedures in the interest of improved performance without notifying owners Under no circumstances should any alignment be attempted unless the normal function and operation of the repeater are clearly underst...

Страница 2: ...ginning Note Signal levels in dB referred to in the alignment procedure are based on 0dBµ 0 5µV Set up the test equipment as shown below and apply AC power to the repeater The repeater must be programmed for use in the intended system before alignment is attempted The frequency and other parameters are loaded from the file during the alignment process In order to facilitate alignment over the comp...

Страница 3: ...y counter to J3001 on the RX Unit r Select the Center channel adjust TC3001 on the RX Unit if necessary so that the frequency counter reading is within 100Hz of the programmed Center channel frequency Receiver parameters excluding PLL r The following receiver parameters can be adjusted from the computer by utilizing the CE 27 Channel Alignment Diskette Refer to the onboard help of the CE 27 Channe...

Страница 4: ...ter channel Audio Level Adjustment LINE OUT Level r Inject a signal on the Center channel frequency at a level of 40 dBµ 1 kHz tone 3 0 kHz deviation from the RF Signal Generator into the RX antenna jack and adjust VR4002 on the CNTL Unit so that the Line Out audio level LINE jack pins 5 and 6 is 10 dBm 0 1 dBm Deviation Adjustment LINE IN Level r Connect the AF generator to LINE jack pins 3 and 4...

Отзывы: