8
VX-1400 Series Service Manual
Alignment
Preparation
Please back up the data of VX-1400 (following refer-
ence).
3. "Save As" function in the "File"
menu of CE111.
4. "Save" function in the "File" menu
of CE111.
PLL Reference Frequency Alignment
Press and hold in the [
P1
], [
P2
], [
P0
] and [
P3
] keys,
while turning the radio on, to enter the alignment
mode.
Connect the Frequency Counter to TP4044 on the
MAIN Unit.
Press the [
] / [
] key for 22.625 MHz ±1Hz on the
Frequency Counter.
Press and hold in the [
MENU
] button for 2 seconds to
save the new settings and exit from the alignment
mode.
2nd Local Carrier Output Level
Connect the RF millivoltmeter to TP4039 on the MAIN
Unit.
Adjust T4017 on the MAIN Unit for maximum de-
flection on the RF millivoltmeter (more than 40
mVrms).
PLL VCV Voltage
Connect the Digital DC voltmeter (high-Z) to TP4058
on the MAIN Unit.
Referring to the table below, adjust the listed compo-
nents for the required voltage, or confirm that the cor-
rect voltage is present on each frequency listed (It does
again).
TX IF Circuit (SSB/CW)
Connect the 50-Ohm Dummy Load and Wattmeter to
the "ANT" jack.
Disconnect the TMP plug from J4002 on the RF-IF-
Unit, and then connect the RF millivoltmeter and 50
Ohm dummy load to J4002.
Inject the 1 mV, 1 kHz audio signal to MIC Terminal
of MIC jack.
Press the [
⊳
]/[
], [
] / [
] button to select the
"memory channel 015".
Press the PTT button; adjust T4015, T4012, T4013,
T4014, and T4011 on the MAIN-Unit for maximum
deflection on the RF millivoltmeter (Please adjust it
again).
Disconnect the RF millivoltmeter and 50 Ohm dummy
load from J4002 on the MAIN-Unit, then re-connect
the TMP plug to J4002.
RX IF Circuit (SSB/CW)
Connect the AF millivoltmeter and 4 Ohm dummy
load to the EXT SPKR jack.
Connect the RF Signal Generator to the "ANT" jack,
P l e a s e s e l e c t " V X - 1 4 0 0
Alignment.c111" clicking "File"-
"Open".
Please select "Radio"-"Download" and return it to
former data when the adjustment ends.
➠
Install the CE111 (Clone Editor) to your PC.
Set the "VOL" of VX-1400 to the position of "12-
o'clock".
Connect the VX-1400 to a computer with a Clone cable.
1. "Upload" function in the "Radio" menu of CE111.
2. Click on the [ON] button.
CH
010
011
012
013
VCO
VCO1
VCO1
VCO2
VCO2
Adjustment
5.2 ± 0.1 V
> 0.6 V
5.2 ± 0.1 V
> 0.6 V
Transceiver
Inline
Wattmeter
Power Supply
13.8 VDC
Frequency
Counter
RF
Signal Generator
50-ohm
Dummy Load
MIC
COM Port
CE111 Programming Software
ANT
RF Sampling
Coupler
INPUT
VPL-1 or FIF-10+CT-104A
Programming Cable
Содержание VX-1400
Страница 4: ...4 Exploded View Miscellaneous Parts VX 1400 Series Service Manual Note ...
Страница 5: ...5 Block Diagram VX 1400 Series Service Manual ...
Страница 6: ...6 Connection Diagram VX 1400 Series Service Manual ...
Страница 14: ...14 VX 1400 Series Service Manual Alignment Note ...
Страница 15: ...PANEL Unit 15 VX 1400 Series Service Manual Circuit Diagram ...
Страница 16: ...16 PANEL Unit VX 1400 Series Service Manual Note ...
Страница 22: ...22 VX 1400 Series Service Manual PANEL Unit Note ...
Страница 23: ...23 VX 1400 Series Service Manual Circuit Diagram MAIN Unit ...
Страница 47: ...PA Unit 47 VX 1400 Series Service Manual Circuit Diagram ...
Страница 48: ...48 PA Unit VX 1400 Series Service Manual Note ...
Страница 50: ...50 PA Unit VX 1400 Series Service Manual Parts Layout Side B a b c d e 1 2 3 f 4 5 6 7 g i h j 8 ...
Страница 58: ...58 VX 1400 Series Service Manual PA Unit Note ...
Страница 59: ...59 ALE 2 Unit Option VX 1400 Series Service Manual Circuit Diagram ...
Страница 64: ...64 VX 1400 Series Service Manual ALE 2 Unit Option Note ...
Страница 65: ...65 VX 1400 Series Service Manual ...