background image

 

  www.versitron.com 

  
 
 

TABLE OF CONTENTS 

 

 

SECTION 1: GENERAL DESCRIPTION 

 
 

INTRODUCTION…………………………………………………………………….4 
DESCRIPTION OF EQUIPMENT…………………………………………………...4 

FUNCTIONAL CHARACTERISTICS……………………………………………....5 
PHYSICAL CHARACTERISTICS……………………………………………..........5 

SPECIFICATIONS…………………………………………………………..........5-6 

 
 

SECTION 2: INSTALLATION 

 
 

INSTALLATION PROCEDURE……………………………………………………7 

SYSTEM DIP SWITCH SETTINGS………………………………………………..8 

SYSTEM TERMINAL BLOCK CONNECTIONS……………................................8 
INDICATOR LEDs………………………………………………………………….9 

TRANSMITTER AND RECEIVER…………………………………………………9 

 
 

 

SECTION 3: TROUBLESHOOTING 

 

 
 

OPTICAL FIBER………………………………………………………………….10 

GENERAL……………………………………………………………………........10 
DATA LINK……………………………………………………………………….10 

 
 

 

LIST OF ILLUSTRATIONS 

 
 

FIGURE 1: FVT1103 and FVR1103……………………………………………….5 

FIGURE 2: PSACV1 Power Supply………………………………………………..7 
FIGURE 3: VCA1100 Data Cable………………………………………………….7 

 
 
 
 
 
 
 

 

Содержание FVR1103

Страница 1: ...ersitron com VersiVision FVT1100 FVR1100 Series Fiber Optic Video Modems Technical Manual Also covers FVR1100M modules Copyright Aug 2005 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versit...

Страница 2: ...of delivery We will repair or at our option replace parts which during normal usage prove to be defective during the warranty period provided that 1 You call VERSITRON at 302 894 0699 or 800 537 2296...

Страница 3: ...CS 5 SPECIFICATIONS 5 6 SECTION 2 INSTALLATION INSTALLATION PROCEDURE 7 SYSTEM DIP SWITCH SETTINGS 8 SYSTEM TERMINAL BLOCK CONNECTIONS 8 INDICATOR LEDs 9 TRANSMITTER AND RECEIVER 9 SECTION 3 TROUBLESH...

Страница 4: ...3M Receiver module 1 channel simplex video 1 channel return data Multimode ST 3km installed in Model FVC14 chassis FVR1104M Receiver module 1 channel simplex video 1 channel return data Multimode SC 3...

Страница 5: ...re required LED status indicators include video sync present VD data transmitted TD data received RD and power on PWR Physical Characteristics The VersiVision FVT1100 transmitter and FVR1100 receiver...

Страница 6: ...6 3 x 1 2 in Shipping Weight 4 4kg Construction Aluminum Finish Black Paint INDICATOR Module Green Video Sync Present Red Power On Blue Data Transmitted Received OPTICAL POWER BUDGET Transmitter Recei...

Страница 7: ...Ds on the units for monitoring the real time status of video power and data The following instructions describe the typical installation procedure and the function of the LED indicators located on eac...

Страница 8: ...Data Input Output Connector RS 485 2 wire Red Wire Signal being transmitted or received over fiber Blue Wire Signal being transmitted or received over fiber RS 485 Connection Camera Site Using the VCA...

Страница 9: ...ne data LED on each unit One labeled as Power or PWR lights when operating power is present Another labeled as Video or VID lights when the video input output signals are detected The other one labele...

Страница 10: ...or has too much attenuation Next be certain to check all connections and assure that inputs and outputs are not intermixed and the transmitter and receiver are not connected incorrectly DATA LINK Even...

Страница 11: ...11 www versitron com FIGURE 4 VersiVision FVT110x FVR110x Connection Layout...