229
A
PPLICATION
NORAC UC5
Boom Height Control Options Screen
Pressing the
Boom Height Control
Options button (A)
opens the
Boom
Height Control Options screen (B)
. At
this screen, you can adjust the boom’s
Mode, Sensitivity and Target Height.
• Mode
The drop-down menu is where you can choose
one of two modes:
- In
Soil Mode
, the UC5 controls boom height
relative to the distance from the soil.
- In
Crop Mode
, the UC5 controls boom height
relative to distance from the crop canopy.
• Sensitivity
Adjusts the boom response. Higher values
make the height control more responsive;
settings range from 0-10.
• Target Height
User-defined boom height in relation to the selected control mode.
B
OOM
H
EIGHT
D
IAGNOSTICS
The Boom Height Diagnostics screen shows all data for individual sensors, including Height, Roll and
Temperature.
To go to the Boom Height Diagnostics screen, press on the Device Information button. At
the Devices screen, highlight the item marked NORAC UC5 then press the Diagnostics
button.
The NORAC UC5 Diagnostics screen
appears.
Mode: Crop
Target Height: 12 in
Sensitivity: 5
15.9
8.4
8.4
50 F
Boom Height Control Options
Crop Mode
Sensitivity
Target Height
5
12
Boom Height Diagnostics
General
Control Mode
Target Height (cm)
Remote Switch
Crop
30.4
1
2
3
Location
Serial
100
103
101
91 cm
89 cm
102 cm
Left
Center
Right
-
Roll
Automatic
Boom Control State
Height / Roll
Temperature
21.1 C
84 cm
8.0
104
102
105
N/A
Automatic
Automatic
Automatic
21.1 C
21.1 C
21.1 C
21.1 C
Left Outer
Left Inner
Main Lift
Right Inner
Right Outer
Boom Frame
4
5
6
81 cm
Содержание ag leader
Страница 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Страница 2: ...Firmware Version 5 4 ...
Страница 20: ...6 Firmware Version 5 4 ...
Страница 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Страница 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Страница 56: ...42 Firmware Version 5 4 ...
Страница 78: ...64 Firmware Version 5 4 ...
Страница 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Страница 84: ...70 Firmware Version 5 4 ...
Страница 94: ...80 Firmware Version 5 4 ...
Страница 108: ...94 Firmware Version 5 4 ...
Страница 140: ...126 Firmware Version 5 4 ...
Страница 154: ...140 Firmware Version 5 4 ...
Страница 158: ...144 Firmware Version 5 4 ...
Страница 162: ...148 Firmware Version 5 4 ...
Страница 222: ...208 Firmware Version 5 4 ...
Страница 244: ...230 Firmware Version 5 4 ...
Страница 260: ...246 Firmware Version 5 4 ...
Страница 289: ...275 HARVEST H ARVEST M ONITORING M APPING Motor Current Measure of Elevator Mount Unit EMU current shown in amps ...
Страница 290: ...276 Firmware Version 5 4 ...
Страница 304: ...290 Firmware Version 5 4 ...