Vernier Go Direct GDX-WRT Скачать руководство пользователя страница 1

1

6. Click or tap your Go Direct sensor

from the list of Discovered
Wireless Devices. Your sensor's ID
is located near the barcode on the
sensor. The Bluetooth LED will
blink green when it is successfully
connected.

7. Click or tap Done to enter data-

collection mode.

Charging the Sensor

Connect Go Direct Wide-Range Temperature to the included Micro USB Cable
and any USB device for two hours.

You can also charge up to eight Go Direct Wide-Range Temperature Probes
using our Go Direct Charge Station, sold separately (order code: GDX-CRG).
An LED on each Go Direct Wide-Range Temperature indicates charging status.

Charging

Blue LED on steady while sensor is connected to
the Charging Cable or Charging Station.

Fully charged

Blue LED is off when charging is complete.

Providing Power

Turning on the sensor

Press button once. Red LED indicator flashes
when unit is on.

Putting the sensor in sleep
mode

Press and hold button for more than three
seconds to put into sleep mode. Red LED
indicator stops flashing when sleeping.

Connecting the Sensor

See the following link for up-to-date connection information:

www.vernier.com/start/gdx-wrt

Connecting via Bluetooth

Ready to connect

Red LED flashes when sensor is awake and
ready to connect via Bluetooth.

Connected

Green LED flashes when sensor is connected via
Bluetooth.

Go Direct

®

Wide-Range
Temperature

(Order Code GDX-WRT)

This rugged temperature probe features a wide temperature range, from –20°C to
330°C. The high upper limit of the sensor allows for melting point
determinations of most organic compounds. It uses platinum RTD (Resistance
Temperature Detector) technology to establish a ±0.5°C accuracy or better, as
well as excellent stability and repeatability. Each unit is individually calibrated,
and the calibration is stored on the sensor. It is designed to be used as you
would use a thermometer for experiments in organic and inorganic chemistry,
physics, biology, Earth science, and environmental science.

Note:

Vernier products are designed for educational use. Our products are not

designed nor are they recommended for any industrial, medical, or commercial
process such as life support, patient diagnosis, control of a manufacturing
process, or industrial testing of any kind.

What's Included

l

Go Direct Wide-Range Temperature

l

Micro USB Cable

Compatible Software

See

www.vernier.com/manuals/gdx-wrt

for a list of software compatible with

Go Direct Wide-Range Temperature.

Getting Started

Please see the following link for platform-specific connection information:

www.vernier.com/start/gdx-wrt

Bluetooth Connection

USB Connection

1. Install Graphical Analysis 4 on

your computer, Chromebook™, or
mobile device. See
www.vernier.com/ga4 for software
availability.

2. Charge your sensor for at least

2 hours before first use.

3. Turn on your sensor by pressing

the power button once. The
Bluetooth

®

LED will blink red.

4. Launch Graphical Analysis 4.
5. Click or tap Sensor Data

Collection.

1. Install Graphical Analysis 4 on your

computer or Chromebook. If using
LabQuest 2, make sure LabQuest
App is up to date. See
www.vernier.com/ga4 for software
availability or
www.vernier.com/downloads to
update LabQuest App.

2. Connect the sensor to the USB port.
3. Launch Graphical Analysis 4 or turn

on LabQuest 2. You are now ready
to collect data.

Отзывы: