9
20300058
VSW30 Series Wood Stove
CLEARANCES
CLEARANCES TO COMBUSTIBLES
(UL-1482 ANd ULC-S627)
Minimum clearances to combustible materials in inches. NOTE: All “A,” “C,” and “F”
dimensions are to the stove pipe.
A
B
C
D
E
F
E
F
G
H
I
ST1048
clearances
A
B
C
d
E
F
G
h
I
Installation: Full Vertical
Single Wall Pipe
Flat Top Model
14
Z\x
"
11"
21
Z\x
"
11"
7"
16
C\v
"
51"
14"
11"
(368 mm) (279 mm) (546 mm) (279 mm) (178 mm) (426 mm) (1295 mm) (356 mm) (279 mm)
Step Top Model
11
Z\x
"
8"
18
Z\x
"
8"
5
Z\x
"
15
Z\v
"
51"
14"
8"
(292 mm) (203 mm) (470 mm) (203 mm) (140 mm) (394 mm) (1295 mm) (356 mm) (203 mm)
double Wall Pipe
Flat Top Model
10
Z\x
"
7"
17
Z\x
"
7"
7"
16
C\v
"
51"
14"
7
(267 mm) (178 mm) (445 mm) (178 mm) (178 mm) (426 mm) (1295 mm) (356 mm) (178 mm)
Step Top Model
10
Z\x
"
7"
17
Z\x
"
7"
5
Z\x
"
15
Z\v
"
51"
14"
7"
(267 mm) (178 mm) (445 mm) (178 mm0 (140 mm) (400 mm) (1295 mm) (356 mm) (178 mm)
Installation: 90° elbow off top of stove through back wall
Single Wall Pipe
Flat Top Model
14
Z\x
"
11"
21
Z\x
"
11"
n/a
n/a
51"
14"
11"
(368 mm) (279 mm) (546 mm) (279 mm)
(1295 mm) (356 mm) (279 mm)
Step Top Model
14
Z\x
"
11"
21
Z\x
"
11"
n/a
n/a
51"
14"
8"
(368 mm) (279 mm) (546 mm) (279 mm)
(1295 mm) (356 mm) (203 mm)
Installation: Alcove—Six inch (6") (152 mm) diameter listed double wall air insulated connector
pipe with UL 103 HT listed factory-built Class “A” chimney, or a masonry chimney. (Mobile home
must be equipped with a spark arrestor). Maximum depth of alcove shall be no more than 48"
(1220 mm). Please refer to NFPA 211.
double Wall Pipe
Flat top model NFPA min.
Step top model NFPA min.
Figure 8 -
Clearances to Combustibles
Содержание VSW30FTAL
Страница 21: ...21 20300058 VSW30 Series Wood Stove...
Страница 22: ...22 20300058 VSW30 Series Wood Stove...
Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...