87D0058
15
SB50HB Series Woodburning Fireplace
FIrepLaCe COMpONeNTS
FP2225
SB6000 fireplace components
SB50HB
WSB60B,
GD60B
Glass Doors
AK4 Combustion Air
Assembly
SLTCF11
Chimney Cap
RLTCF11L
Extended Chimney
Cap
H074 Hearth
Extension Kit
11CF30-
Elbow
11CS
Chimney Support
11CF4 11CF3 11CF18 11CF1
Chimney Sections
8-6-1 or 8-1-1
Flashing
FSA or FS6A
Firestop
Flat Washer
36” or 7” (13
Z\x
” Dia. Hole)
Fireplace Components
Model
description
SB50HB
50” front opening fireplace. Includes firescreen, sealing flue damper and outside combustion air capa-
bility. When installed, outside combustion air can be connected to either left or right side. Refer to
installation instructions for details.
11CF1
1” chimney section
11CF18
18” chimney section
11CF3
36” chimney section
11CF4
48” chimney section
11CF30-
30° elbows (package contains two 11” diameter elbows) One pair is required for each offset.
11CS
Chimney support (required when chimney height exceeds 30 feet)
SLTCF11
Chimney cap for contemporary installations.
RLTCF11
Round chimney cap for contemporary installations.
RLTCF11L Extended chimney cap for contemporary installations.
8-6-1
0-6/1 pitch flashing for contemporary installation.
8-1-1
6/1 to 1/1 pitch flashing for contemporary installation.
FSA
Vertical Firestop spacer - One required at each ceiling or floor level.
FS6A
30° Firestop spacer - for 30° chimney incline through ceiling or floor.
FP-4-U
4” insulated combustion air duct, 8’ length.
403
4” duct connector (for splicing FP-4 ducts). Includes clamps.
AK4
4” outside combustion air assembly.
WSB60B, GD60B
Optional polished brass glass door kit.
S0BR/BT/BW/S0UB
Top Housing with Upper Baffle
FS100-HT Attic Insulation Shield (not shown)
S0BR/BT/BW
Top Housing
S0UB Upper
Baffle