background image

4

Resolute

®

 Acclaim Woodburning Stove

30003843

Resolute Acclaim Woodburning Stove

Model 2490CE (continued)

 

 

item Description 

part Number

 

 

item Description 

part Number

  17.  Griddle Handle Screw 

101308

  18.  Top 

See Chart Pg. 4

  19.  Combustion Package 

160497

  0.  Sealing Plates () 

1301859

  1.  Arch Brick Retainer 

1600154

  .  Left Arch Brick 

1600151

  3.  Right Arch Brick 

160015

  4.  Rear Grate 

1301851

  5.  Front Grate 

130185

  6.  Pit Plate 

1301804

  7.  Andiron () 

1301806

  8.  Tie Rod (4) 

1601640

  9.  Left End 

See Chart Pg. 4

  30.  Ash Pan 

5005775

  31.  Left Inner Side 

1301855

 3a.  Left Side Firebrick 

1600153

 3b.  Right Side Firebrick 

30004689

  33.  Left Shoulder Plate 

1301863

  34.  Leg (4) 

See Chart Pg. 4

  35.  Package Support Plate 

1301809

  36.  Bottom 

1301854

  37.  Right Shoulder Plate 

1301864

  38.  Ashlip 

See Chart Pg. 4

  39.  Air Valve 

1301814

  40.  Air Valve Shaft 

160061

  41.  Air Valve Handle / Door Handle 

1600663

  51.  Right Inner Side 

1301856

  5.  Right End 

See Chart Pg. 4

  53.  Damper Handle Stub w/ Set Screw 

300070

  54.  Damper Handle 

1600664

  55.  Damper Handle Screw 

101310

  56.  Air Manifold 

1301803

  57.  Front 

1301861

  58.  Glass Retainer () 

1601399

  59.  Glass 

140110

  61.  Door 

See Chart Pg. 4

  6.  Door Hook 

1600155

  63.  Door Handle Shaft 

160063

  64.  Latch Retainer 

101843

  65.  Compression Spring 

1600551

  66.  Upper Door Pin 

1600550

  67.  C-Clip 

1600553

  68.  Pin, Hinge Bottom 

1600419

  69.  Nut, Hex 5/16-18 

10379

  Shell Enamel parts - Resolute Acclaim

 

Enamel 

 

left 

Right 

Flue 

Flue 

 

 

  Color 

Top 

Side 

Side 

Collar 

Cover 

Ashlip 

Door 

leg

  Classic 

130186 

1301857 

1301858 

1301816 

1301817 

1301819 

1301865 

1301833

  Biscuit 

30003118  30003119  3000310  3000311  300031  30003117  3000313  30003116

  Bordeaux 

3186 

31857 

31858 

31816 

31817 

31819 

31865 

31833

  Brown 

 

 

 

 

 

 

 

 

 

  Majolica 

30004887  30004888  30004889  30004890  30004891  30004886  3000489  30004885

  Chestnut 

 

 

 

 

 

 

 

 

 

  Brown 

3000317  3000318  3000319  30003130  30003131  3000316  3000313  3000315

  Ebony 

30003136  30003137  30003138  30003139  30003140  30003135  30003141  30003134

  Forest 

 

 

 

 

 

 

 

 

 

  Green 

31186 

311857 

311858 

311816 

311817 

311819 

311865 

311833

  Midnight 

 

 

 

 

 

 

 

 

 

  Blue 

37186 

371857 

371858 

371816 

371817 

371819 

371865 

371833

  Sand 

13186 

131857 

131858 

131816 

131817 

131819 

131865 

131833

  Suede 

 

 

 

 

 

 

 

 

 

  Brown 

3000560  3000561  300056  3000563  3000564  3000559  3000565  3000558

  VT. Classic 

 

 

 

 

 

 

 

 

 

  Green 

30003145  30003146  30003147  30003148  30003149  30003144  30003150  30003143

Содержание Resolute Acclaim 2490CE

Страница 1: ... Stove Model 2490CE 0893 Safety Notice If this appliance is not properly installed operated and main tained a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local building officials about restrictions and installation inspection requirements in your area ...

Страница 2: ...andards set forth by the Federal Environmental Protection Agency 40 CFR Part 60 532 b 2 as stated on the permanent label attached to each stove In addition to directions on installation and operation this manual includes directions on maintenance and assembly We recommend that you hire a professional solid fuel stove installer to install your stove or to advise you on the installation should you a...

Страница 3: ...e size Min 152 mm 6 or 203 mm 8 Flue exit position Reversible top or rear Primary air Manual Secondary air Preset Ash handling system Removable ash pan Specifications Resolute Acclaim Model 2490CE Glass panel High temperature ceramic Weight 192 kg 425 lbs Width leg to leg 660 mm 26 Depth leg to leg 480 mm 19 Height to top of flue collar w Regular legs 699 mm 27 top exit 635 mm 25 rear exit w Short...

Страница 4: ...need to be com plied with when installing this stove What Kind of Chimney to Use Your Resolute Acclaim may be connected either to a sound masonry chimney that meets local codes to a relined masonry chimney that meets local codes or to an approved prefabricated metal chimney Whatever kind you use the chimney and chimney connector must be in good condition and kept clean If you use an existing mason...

Страница 5: ... cement Double wall connectors must be tested and listed for use with solid fuel burning appliances Single wall con nectors should be made of 24 gauge or heavier steel and should be 6 152 mm in diameter Do not use galvanized chimney connector it cannot withstand the high temperatures that can be reached by smoke and exhaust gases and may release toxic fumes under high heat If possible do not pass ...

Страница 6: ... connector When assembled in this way any soot or creosote fall ing from the inner walls of the chimney will stay inside the chimney connector Securing the Single wall Connector to a Masonry Chimney Both freestanding masonry chimneys and fireplace masonry chimneys may be used for installation of your Resolute Acclaim Freestanding Installations If the chimney connector must pass through a com busti...

Страница 7: ...nstall a Resolute Acclaim through the open ing using a positive connection kit available from your local dealer These kits provide a secure connection between the stove flue collar and the chimney flue Fig 8 If it is necessary to reverse the flue collar from the top exit to the rear exit position follow the directions on Page 9 Fireplace installations whether connected to the flue above or through...

Страница 8: ...ons in document J and should be of minimum width 840 mm and minimum depth 840 mm if a free standing hearth b above or a mini mum projection of 150 mm from the jamb if a recessed hearth a above Floor Protection for Fireplace Installation Do not assume that your fireplace hearth is completely noncombustible Many fireplace hearths do not satisfy the completely noncombustible requirement because the b...

Страница 9: ...d Detailed information on fireplace and hearth construction is provided in section 2 of Document J all installations must comply with these requirements or with the relevant National or local building standards Clearances to timber framed studded walls are in cluded below There are no specific minimum clearanc es to solid noncombustible surfaces e g the sides and rear of Inglenook fire openings co...

Страница 10: ...Remove the four 4 fasteners that hold the collar and extension plate The fasteners are accessible by reaching through the flue collar of the stove 2 Remove the flue collar and extension plate 3 Examine the exposed gasket contact your Vermont Castings Authorized Dealer if the gasket needs to be replaced 4 Position the extension plate and flue collar in the appropriate orientation making sure the ga...

Страница 11: ...Immediately notify your dealer of any damage Do not install this stove if any damage is evident or any parts are missing Hardware Bag contents Stove Legs 4 3 8 16 x 1 hex head Leg Bolts with washers 4 Owner s Registration Card Touch up Paint Porcelain enamel stoves Install Stove Legs Remove and discard the four large slot head screws from the stove bottom Install the stove legs using the hex head ...

Страница 12: ...decreased burn times Wood should be stored under cover to maintain dry ness Even for short term storage keep wood a safe distance from the heater and keep it out of the areas around the heater used for refueling and ash removal Use the Air Control Settings That Work Best for You No single control setting will fit every situation Each operation will differ depending on the quality of the fuel the a...

Страница 13: ...amber that is located in the center of the lower fireback If your wood is well seasoned the damper may be closed when the griddle temperature reaches 260 C 500 f Depending on the type of wood being burned and its moisture content it may take several hours to establish and then maintain the ember base that is required for high efficiency operation 5 Once the ember bed is formed prepare the stove fo...

Страница 14: ...es and will be confirmed by a temperature on the griddle of at least 260 C 500 F Close the damper and set the primary air lever for the desired heat output NOTE If the remaining charcoal bed is relatively thick and if your fuel is well seasoned it is possible to add fresh fuel smaller pieces first close the door and damper and reset the primary air within 5 minutes A Surface Thermometer is a Guide...

Страница 15: ...ncy will vary depending on how hot you run your stove the hot ter the fire the more wood you burn and the faster ash will accumulate The ash pan is located in the ash drop chamber with a handle attached to the front and one to the rear Always use stove gloves when handling the ash pan Keep it level and carry it outside for disposal Empty the ash into your ash disposal container When you are fin is...

Страница 16: ...less heat from the stove to get it warm and keep it warm Flue sizing The inside size of a chimney for an airtight stove should match the size of the stove s flue outlet When a chimney serves an airtight more is not better in fact it can be a disadvantage Hot gases cool off through expansion if we vent a stove with a 152 mm 6 flue collar 181 sq cm 28 sq in area into a 254 x 254 mm 10 x 10 flue the ...

Страница 17: ...hem out of the firebox The gases back up in the firebox till they re dense enough and hot enough to ignite If your stove back puffs you should open up the damper to let the smoke rise to the flue more quickly let more air into the firebox and avoid big loads of firewood Run your stove with enough primary air so that you always see lively dancing flames in the firebox a lazy smoky fire is inefficie...

Страница 18: ...f regularly during hot fires If you wish to clean the glass more thoroughly follow this procedure Let the stove and glass cool completely Wash the glass with warm water and a soft paper towel or rag Rinse and dry thoroughly Never use abrasives ashes or harsh chemicals to clean your Resolute Acclaim glass For stubborn deposits use a ceramic glass cleaner available from your Vermont Castings Authori...

Страница 19: ...ibed above Adjust the gasket in any areas where an inadequate seal is evident Adjust the Door Although it is unlikely that adjusting it will be necessary the height of the Resolute Acclaim s front load door is adjustable The lower door hinge pin has a shoulder that lifts or lowers the door as you screw the pin up or down Repair Missing Cement in Seams The cement in the stove seams may deteriorate ...

Страница 20: ...h their application Resolute Acclaim Gaskets on Moving Parts Gasket Size And The Parts It Seals 3 16 The glass to the load door frame 5 16 wire mesh The griddle to the stove top 1 2 The arch and bottom edge of the inner front stove panel to the front load door 1 2 The front of the grate to the front load door Should you need to change a replaceable gasket wait until the fire is out and the stove h...

Страница 21: ...ize Creosote and Soot When you first begin using the stove check daily for creosote a substance that can look like either thick tar or black crisp flakes Experience will show how often you need to clean to be safe The frequency may even vary during the year In the colder months when the hottest fires producing the least creosote are burned you may need to clean less frequently Dur ing the warmer m...

Страница 22: ...or hire a qualified chimney sweep in your area to do the job Resolute Acclaim Maintenance Schedule The stove and chimney system should be inspected and maintained by a qualified engineer and include the following Stove Daily Ashes should be removed before they reach the top of the ash pan Check at least once a day Keep the area around the stove clear of any com bustible material Two Months Check d...

Страница 23: ...parts 8 02 83 68 67 69 64 7 7 Resolute Acclaim Woodburning Stove Model 2490CE Item Description Part Number Item Description Part Number 1 Flue Collar See Chart Pg 24 2 Back 1301860 3 Damper Rod 1600853 4 Spacer 1201780 5 Washer 3 8 1202488 6 Damper Ramp 1301811 7 Damper Tab 1601488 8 Damper 1301829 9 Upper Fireback 1301805 10 Flue Cover See Chart Pg 24 11 Left Griddle Quad Pre 2010 1301807 11a Lef...

Страница 24: ... 58 Glass Retainer 2 1601399 59 Glass 1401120 61 Door See Chart Pg 24 62 Door Hook 1600155 63 Door Handle Shaft 1600623 64 Latch Retainer 1201843 65 Compression Spring 1600551 66 Upper Door Pin 1600550 67 C Clip 1600553 68 Pin Hinge Bottom 1600419 69 Nut Hex 5 16 18 1203279 Shell Enamel Parts Resolute Acclaim Enamel Left Right Flue Flue Color Top Side Side Collar Cover Ashlip Door Leg Classic 1301...

Страница 25: ...25 Resolute Acclaim Woodburning Stove 30003843 ...

Страница 26: ...26 Resolute Acclaim Woodburning Stove 30003843 ...

Страница 27: ...f original purchase date 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This warranty is transferable however proof of original retail pur chase is required 2 This warranty does not cover misuse of the stove Misuse includes overfiring which will result if ...

Страница 28: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...

Отзывы: