10
Resolute
®
Acclaim Woodburning Stove
30003843
34
FLUEPIPECLEARANCES
D
at least
3 x D
Elevation
Without
Shield
Elevation
With Shield
at least
3 x D
at least
1.5 x D
at least 1.5
x D
plan Without
Shield
plan With
Shield
Air space of at least 1 mm
between noncombustible shield
and combustible material
Fluepipe
at least
1.5 x D
at least
1.5 x D
at least 3 x D
D
at least
1.5 x D
ST911
Fig. 12
Connecting fluepipe clearances.
Reversing the Flue Collar
Your Resolute Acclaim is shipped with the flue collar in
the top exit position. Depending on your requirements,
you may wish to reverse the flue collar and extension
plate to the rear exit position. The only tool necessary is
a 11 mm (7/16”) wrench.
To reverse the flue collar position:
1. Remove the four (4) fasteners that hold the collar
and extension plate. The fasteners are accessible
by reaching through the flue collar of the stove.
. Remove the flue collar and extension plate.
3. Examine the exposed gasket; contact your Vermont
Castings Authorized Dealer if the gasket needs to be
replaced.
4. Position the extension plate and flue collar in the
appropriate orientation, making sure the gasket
remains in place. The notched edge of the extension
plate should be next to the griddle.
5. Secure the extension plate and flue collar with the
fasteners removed in the first step. Run the bolts in
only finger-tight. Adjust the fit of the extension plate
and/or flue collar if necessary. Tighten all four (4)
fasteners, but do not overtighten them. Test the ac-
tion of the griddle; make any needed adjustments by
loosening the hardware, repositioning the flue collar
and extension plate, retesting the griddle action, and
retightening the hardware.