background image

25

Vermont Castings Madison

Madison Woodburning Stove

Model 1655 (continued)

Item Description

Part Number

23. Brick Support

30000804

24. Secondary Air Tube (Rear)

30001493

25. Secondary Air Tube (Middle)

30001494

26. Secondary Air Tube (Front)

30001495

27. Friction Spring

1201846

28. Leveller Blt, Hx Hd 1/4-20 x 1” Z

1201745

29. Washer, 1/4 pl 7/8 o.d.

1202470

30. Pan Hd, PH 10-24 x 1” blk

1200907

31. Nut, Square, 1/4-20 Pln

1203329

32. Insert Door Handle, Holder

1600600

33. Latch, Door

1408628

34. Pan Hd, 10-24 x 1/4” Z

1200996

35. Fl Hd, PH 1/4-20 x 1

³⁄₄

” Blk

1200830

36. Front Handle w/ Shift

5004245

37. Pawl Assy., Ash Door

5004025

38. CS, Hex Hd 1/4-20 x 5/8” Blk

1201372

39. Fl Hd. Allen 1/4-20 x 3/4” Blk

30001166

40. Ashpan Assy.

30001167

41. Cover Plate, Primary Air

30001393

42. Heat Shield, Flue Collar

30001456

43. Thermostat Sub Assy.

30001390

44. Thermostat Cover

30001414

45. Fl Hd, PH 1/4-20 x 2.50 - Blk

30001444

15

14

16

17

1

10

8

12

11

3

2

9

5

4

7

6

18

Madison Doors Exploded View

5. Glass, Door, Left

1408630

6. Glass Retainer

30000474

7. Pan hd, PH 10-24 x 3/8-Z

1200983

8. Hinge Strap, Door -Right Hand

30001222

9. Hinge Strap, Door - Left Hand

30001223

10. Pin, Long, Door

1600547

11. CS, Hex Hd 1/4-20 x 3/8 Gr. 5 Blk

1201337

12. Washer, Flat 1/4-Z

1202474

Fallaway Handle Complete

0004342

14. Handle, Ceramic

1600620

15. Oval Head Slotted Screw 1/4-20 x 3/375 1201294
16. Griddle Opener/Insert Door Handle

1600650

17. Door Handle Assy w/set screw

30001759

18. SS, Soc 7/16-20X1 Cup Pt.-Blk.

1200334

Item Description

Part Number

Maintenance Kits Available from your Dealer

1884

Gasket Kit

1876

Thermostat Kit

3427

Gasket Kit for Glass

  Shell Enamel Parts - Madison Model 1655

Part Name

Classic

Green

Moonlight

Sand

Red

Top

30000817

30001213

3001203

30001193

30001183

Left Side

30000797

30001211

30001201

30001191

30001181

Right Side

30000796

30001210

30001200

30001190

30001180

Flue Collar

7000969

2310969

30001258

7020969

2320969

Front

30000808

30001212

30001202

30001192

30001182

Ashlip

30000815

30001214

30001204

30001194

30001184

Left Door

Subassembly

30001173

30001241

30001237

30001233

30001229

Left Door Only

30000810

30001216

30001206

30001196

30001186

Right Door

Subassembly

30001172

30001240

30001236

30001232

30001228

Right Door Only

30000809

30001215

30001205

30001195

30001185

Single Leg

30000816

30001218

30001208

30001198

30001188

Load Door

30000811

30001217

30001207

30001197

30001187

Madison Doors Exploded View

1. Door, Right

See Chart Pg. 25

2. Door. Left

See Chart Pg. 25

3. Gasket, Fiberglas 3/16 4nd, Blk

1203556

4. Glass, Door, Right

1408629

Item Description

Part Number

Содержание Madison 1655

Страница 1: ...RE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT LOCAL BUILDING OFFICIALS...

Страница 2: ...n Agency 40 CFR Part 60 532 b 2 as stated on the permanent label attached to each stove The Madison Model 1655 Series meets Washington State requirements We recommend that you hire a professional soli...

Страница 3: ...e content of the fuel used as well as the design construction and climatic location of your home Figures shown are based on maximum fuel consumption obtained under laboratory conditions and on average...

Страница 4: ...The metal label permanently attached to the back of the stove indicates that the Madison has been tested to current UL and ULC standards by CSA Clearance and installation information is also printed...

Страница 5: ...connection from the stove to the chimney They are for interior use only Double wall connectors must be tested and listed for use with solid fuel burning appliances Single wall connectors should be mad...

Страница 6: ...nnector sections Securing the Single wall Connector to a Prefabricated Chimney Follow the installation instructions of the chimney manufacturer exactly Special adaptors are available from your local d...

Страница 7: ...been tested and listed for use as a wall pass through U S Requirements The National Fire Protection Association NFPA has established guidelines for use in the United States for passing chimney connect...

Страница 8: ...rom left side E Fig 9 Wall Pass through using single wall chimney connector with a ventilated steel thimble Min 6 152mm Chimney clearance to sheet steel supports and combustibles 2 51mm Min Glass Fibe...

Страница 9: ...ned between the stove and nearby combustible materials to ensure that those materials do not overheat Clearance is the distance between either your stove or chimney connector and nearby walls floors t...

Страница 10: ...hields Fig 16 Reduced clearances for both rear and side walls Wall shields may meet at corner if desired Shielding for connector is centered behind connector Wall pass through must comply with codes C...

Страница 11: ...o Durock or equivalent alcove lining I N T R E P I D I I Metal Stud Combustible facing may overlap metal studs by only 1 1 air gap top and bottom on both sides and back wall 7 16 Durock or equivalent...

Страница 12: ...at shields Top exit heat shields on stove no shields on single wall connector Top exit heat shield on stove heat shield on single wall connector Top exit heat shield on stove double wall chimney conne...

Страница 13: ...t Installations no heat shields Top Exit Installations heat shield on stove no shields on single wall connector Top Exit Installations heat shield on stove heat shields on single wall connector Top Ex...

Страница 14: ...to Wall Stove in Corner PROTECTED SURFACES Madison 1655 Series Clearance Diagram UNPROTECTED SURFACES Rear Exit Installations Bottom Heat Shield floor protection minimum 18 457mm in front Y Z AA BB E...

Страница 15: ...lers Leg Bolt and Washer Leg Leveller ST466 Install the Bottom Heat Shield The 1892 Bottom Heat Shield must be used in the U S and Canada in any installation on a floor that is not comprised of unpain...

Страница 16: ...two sheet metal screws provided in the kit to attach the Adaptor to the Rear Heat Shield at the aligned holes Without Rear Heat Shield 1 Facing the rear of the stove loosen the pan head screw located...

Страница 17: ...s Second ary Air enters the stove through two unrestricted inlets and is heated while passing through separate channels before being delivered through three stainless steel multi ported tubes located...

Страница 18: ...vary your firing technique to get the results you desire Starting and Maintaining a Fire Conditioning Your Stove Cast iron is extremely strong but it can be broken with a sharp blow from a hammer or f...

Страница 19: ...on for several minutes after refueling Reset the primary air control for the desired heat output after the fire is re established Ash Disposal Remove ash before it reaches the top of the ash pan Check...

Страница 20: ...s on the inner gasket with the coated side down marked This Side Out toward the outside of the door Tighten the screws snugly but loose enough to allow for a little move ment of the glass when the sto...

Страница 21: ...ney connector should be cleaned by disconnecting the sections taking them outside and removing any deposits with a stiff wire brush Reinstall the connector sections after cleaning being sure to secure...

Страница 22: ...gh flue temperatures Because the insulation is less dense than masonry the inner steel liner warms up more quickly than a masonry chimney Although steel chimneys are not as attractive as their masonry...

Страница 23: ...te is volatile and can generate chimney fire All of the installation characteristics that adversely affect chimney draft also promote creosote condensation Consequently you can minimize creosote accum...

Страница 24: ...tem Description Part Number 1 Bottom Outer 30000795 2 End Left See Chart Pg 25 3 Back 30000798 4 Secondary Manifold Left 30000802 5 Front See Chart Pg 25 6 Load Door See Chart Pg 25 7 Ashlip See Chart...

Страница 25: ...Gr 5 Blk 1201337 12 Washer Flat 1 4 Z 1202474 Fallaway Handle Complete 0004342 14 Handle Ceramic 1600620 15 Oval Head Slotted Screw 1 4 20 x 3 375 1201294 16 Griddle Opener Insert Door Handle 1600650...

Страница 26: ...26 Vermont Castings Madison...

Страница 27: ...cts Company warrants that your Madison will be free of defects in material and workmanship for a period of three years from the date you receive it except that the handles glass door panel fireback ar...

Страница 28: ...28 Vermont Castings Madison Vermont Castings Majestic Products 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7885 www vermontcastings com Vermont Castings Majestic Products...

Отзывы: