Vermont Castings • Encore Model 2040-CAT-C Owner’s Manual_R7 • 2019 - ___ • 06/22
18
8390-204C
Cement
Stove Gasket
Figure 3.5
- Lay a bead of gasket silicone or cement then press
gasket in place.
F. The Chimney System
Creosote
Your Encore
®
Model 2040-CAT-C is designed to reduce
creosote build-up significantly. However, regular chimney
inspection and maintenance must still be performed. For
safety, good stove performance, and to protect your chimney
and chimney connector, inspect your chimney and chimney
connector on a regular schedule. Clean the system if
necessary. Failure to keep the chimney and connector system
clean can result in a serious chimney fire.
6. Starting at one end, press the gasket into the channel,
Figure 3.5. Ensure a good joint where the gasket meets
before trimming any excess. Do not overlap the gasket
ends or leave ends with ragged edges.
7. Press the gasketed part firmly against its normal mating
surface to seat the gasket evenly in its channel. Close
and latch the door to do this, or tap other parts with the
rubber mallet (or hammer/block of wood).
8. Clean any excess cement from around the channel, then
let the cement that holds the new gasket dry thoroughly.
9. The stove’s doors may need adjustment after you have
regasketed them. Initially, it may require loosening the
latch to accommodate the new gasket; after a few weeks,
it may need tightening to compensate for compression of
the new gasket.
All Gasketed Construction Gaskets
Other gaskets form seals between all other non-moving parts,
but these are not subject to the same wear and deterioration
as gaskets on moving parts. It is unlikely that you will ever
need to replace these gaskets unless the involved parts are
disassembled and then put back together. If this is the case,
the job should be done only by a qualified service technician.
5/16” diameter gasket seals the following parts:
• The lower fireback to the back panel
• The left and right air plates (inner sides)
• All connections between the stove plates.
2. Use a wire brush or the tip of a screwdriver to clean
the channel of any remaining cement or bits of gasket.
Remove stubborn deposits of cement with a cold chisel
if necessary, Figure 3.4.
3. Determine the correct length of the appropriate-sized
gasket by laying it out in the channel. Allow an extra 1-2"
(25-50 mm), and mark the spot to be cut.
4. Remove the gasket from the channel, place it on a wood
cutting surface, and cut it at the marked spot with a utility
knife.
Twist the ends slightly to keep the gasket from unraveling.
5. Lay an unbroken 1/8" (3 mm) bead of silicone or cement
in the newly-cleaned channel, Figure 3.5.
When wood is burned slowly, it produces tar, organic vapors
and moisture that combine to form creosote. The creosote
vapors condense in the relatively cool chimney flue of a slow-
burning fire. As a result, creosote residue accumulates on the
flue lining. When ignited, this creosote makes an extremely
hot fire within the flue system that can damage the chimney
and overheat adjacent combustible material. If a significant
layer of creosote has accumulated —1/8” (3 mm) or more
— it should be removed to reduce the risk of a chimney fire.
You can never be too safe. Contact your local fire authority
for information on what to do in the event of a chimney fire,
and have a clearly understood plan on how to handle one.
If you do experience a chimney fire, act promptly to:
• Close the damper and air control lever.
• Get everyone out of the house.
• Call the Fire Department.
Inspect the system every two weeks during the heating
season as part of a regular maintenance schedule. To inspect
the chimney, let the stove cool completely. Then, using a
mirror and a strong light, sight up through the flue collar into
the chimney flue. If you cannot inspect the flue system in this
fashion, the stove must be disconnected to provide better
viewing access.
Clean the chimney using a brush the same size and shape
as the flue liner. Flexible fiberglass rods are used to run the
brush up and down the liner, causing any deposits to fall
to the bottom of the chimney where they can be removed
through the clean-out door.
Clean the chimney connector by disconnecting the sections,
taking them outside, and removing any deposits with a stiff
wire brush. Reinstall the connector sections after cleaning,
being sure to secure the joints between individual sections
with sheet metal screws.
If you cannot inspect or clean the chimney yourself, contact
your local Vermont Castings dealer or a professional chimney
sweep.
WARNING
!
Inspect and Clean Chimney Frequently – Under
certain conditions of use, creosote buildup may occur
rapidly.