background image

Vermont Castings  •  Encore Model 2040-CAT-C Owner’s Manual_R1  •  2019 - ___ •  03/20

8

8390-204C

Operating Instructions 

A. Appliance Controls

 

Two controls regulate the performance of the Encore

®

 Model 

2040-CAT-C: a 

primary air control 

supplies oxygen for the 

fire, and a 

damper

 directs air flow within the stove to activate 

and deactivate the combustion system, Figure 2.1.

Symbols on the stove are reminders of the correct directions 

for using the controls. The words ‘Left’ and ‘Right’ in these 

directions are 

facing the stove

.

Figure  2.1

  -  The  Encore

®

  Model  2040-CAT-C  controls  are 

conveniently located and easy to operate.

A Damper Directs Air Flow Within the Stove

The 

damper handle

 on the left side of the stove operates 

the damper to direct air flow within the stove.

The damper is 

open

 when the handle points to the 

rear

enabling smoke to pass directly into the chimney. The damper 

must be open when starting or reviving a fire, and whenever 

the griddle or doors are opened.
The damper is 

closed

 when the handle points 

down.

 Smoke 

travels through the secondary combustion system where 

it can be further burned, before passing up the chimney, 

Figure 2.3.

The damper should always be either fully open or fully 

closed. There are no intermediate positions. When 

closing the damper, be sure to pull firmly enough to snap 

the handle into the locked position.

This wood heater has a manufactured-set minimum low 

burn rate that must not be altered. It is against federal 

regulations to alter this setting or otherwise operate this 

wood heater in a manner inconsistent with operating 

instructions in this manual.

WARNING

!

A Single Air Control Regulates Heat Output and Burn Time

The 

primary air control lever

, on the right of the stove, 

controls the amount of incoming air for starting, maintaining, 

and reviving a fire.
Once the air control is manually set, a bi-metallic thermostat 

automatically maintains the heat output at a constant level 

for a more even heat over the life of the burn.

More air entering the stove makes the fire burn hotter and 

faster, while less air prolongs the burn at a lower heat output 

level.

For the greatest air supply and maximum heat output (but 

the shortest burn time), move the lever toward the front of 

the stove. For a fire that will last longer with less heat, move 

the lever toward the rear of the unit, Figure 2.2.

ST633

Encore

controls

2/01

Griddle Handle

Damper Handle

Primary Air 

Control Lever

Door Handle Holder 

(Behind leg)

Ashdoor 

Handle

Andirons

Door Handle

ST637

encore

Air control

2/01

Low Heat

High Heat

Figure 2.2 -

 The handle may be positioned anywhere between the 

two extremes for different heat levels.

Damper Positions

ST638

Encore

damper control 

2/01

Open

(Updraft Mode)

Closed

(High Efficiency 

Mode)

Figure 2.3

 - The damper is either open or closed. There are no 

intermediate positions.

Содержание Encore 2040-CAT-C

Страница 1: ...ppliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to com...

Страница 2: ...Regulations to operate this wood heater in a manner inconsistent with operating instructions in the Owner s Manual MODEL MOD LE Encore Model 2040 CAT C LISTED SOLID FUEL ROOM HEATER BURNING FIREPLACE...

Страница 3: ...uct Listing and Important Safety Information A Appliance Certification 6 B BTU Efficiency Specifications 6 C California 6 D Mobile Home Approved 6 E Glass Specifications 6 2 Operating Instructions A A...

Страница 4: ...r occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for pa...

Страница 5: ...or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions in...

Страница 6: ...he products of combustion of such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon monoxide which is know to the State of C...

Страница 7: ...entwiththeoperatinginstructions in this manual Vermont Castings is a registered trademark of Hearth Home Technologies Installation and use of any damaged appliance Modification of the appliance Instal...

Страница 8: ...o snap the handle into the locked position This wood heater has a manufactured set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise o...

Страница 9: ...ypass damper open and the primary air set to its highest position light the newspaper Leave the front door cracked until the kindling ignites then close the doors After most of the kindling has burned...

Страница 10: ...a warm stove If the stove is relatively cold for instance after a long overnight burn the coal bed may need to be re energized prior to adding a large load of wood Open the bypass damper and either t...

Страница 11: ...ever burn liquid based fuels such as kerosene gasoline or alcohol Burning any materials not allowed in these instructions or over firing the stove may void the warranty You ll enjoy the best results w...

Страница 12: ...and pressure also affect draft The control setting also depends on your particular installation s draft or the force that moves air from the stove up through the chimney Draft is affected by such thi...

Страница 13: ...ep ash from falling on the floor do not tilt the ash pan forward If the stove is in operation close the ash door while disposing of the ash You may need to lift the latch end of the door slightly to a...

Страница 14: ...in the appliance s vicinity DO NOT USE GASOLINE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS Appliance Keep all such liquids well away from the...

Страница 15: ...t size for safety reasons as well as performance Canadian law requires a matching liner to serve any stove or insert vented through a fireplace chimney in the US the National Fire Protection Associati...

Страница 16: ...ing and Replacement of Glass Most of the carbon deposits on the glass will burn off during hot fires However the ash residue that accumulates on the glass surface should be removed regularly to preven...

Страница 17: ...htly to prevent air from leaking into the fire chamber The door handle will be positioned vertically when the door is closed Over a period of time the gasket around the door will compress and the latc...

Страница 18: ...of the appropriate sized gasket by laying it out in the channel Allow an extra 1 2 25 50 mm and mark the spot to be cut 4 Remove the gasket from the channel place it on a wood cutting surface and cut...

Страница 19: ...dry Clean the dust from the inner sides of bottom rear or pipe heat shields if your stove is equipped with them Clean surfaces are better heat reflectors than dirty surfaces Touch up the black paint I...

Страница 20: ...ou Figure 3 7 NOTE Burning green insufficiently seasoned wood will result in poorer performance than burning properly seasoned fuel Reloading with green wood can also thermal shock the catalyst result...

Страница 21: ...g fire Check for adequate vent height refer to Chimney Height Section Refer to Negative Pressure section Wood condition is too wet too large Use dry seasoned wood refer to Wood Burning Operation Bed o...

Страница 22: ...Vermont Castings Encore Model 2040 CAT C Owner s Manual_R1 2019 ___ 03 20 22 8390 204C 5 5 Reference Materials Date of Service Performed By Description of Service A Service Maintenance Log...

Страница 23: ...0 CAT C Classic Black 2041 CAT C Biscuit 2042 CAT C Majolica Brown 2044 CAT C Bordeaux 2046 CAT C Twilight 2040T CAT C Classic Black w TransitionDoors 55 77 3 21 17 20 19 16 18 57 12 22 62 56 32 38 31...

Страница 24: ...on Board 30005269 9 Outer Back 30005261 10 Left Griddle Quadrant 30002399A 11 Right Griddle Quadrant 30002401A 12 Griddle 30002386A 13 HS Flue Collar 30005266 14 Bracket Upper Side 30005267 15 Catalys...

Страница 25: ...7 10 35 Refractory Gasket Plate S S SRV8000 008 36 Inner Bottom 30005291 37 Ashdoor Hinge Upper 1 00 30002403 38 Door Handle Bracket 30002909 39 Bottom Outer 30007510A 40 Ashlip Classic Black 30002402...

Страница 26: ...A Left Door Shell Enamel Parts Classic Black 30003938A Biscuit SRV30003958 Bordeaux SRV30006685 Ebony SRV30003962 Majolica Brown SRV30004884 Twilight SRV30007033 Left Door Sub Assembly Shell Enamel Pa...

Страница 27: ...or glass gasket Classic Black 30003975 Biscuit 30003985 Bordeaux 30006686 Ebony 30003989 Majolica Brown 30004881 Twilight 30007073 64B Right Door Transition Door Enamel Classic Black 30007080A Biscuit...

Страница 28: ...c Black 0000555 Biscuit 0000556 Bordeaux 0000560 Ebony SRV30003032 Majolica Brown 0000557 Twilight 0000561 78 Single Leg Classic Black 30002396A Biscuit SRV30003050 Bordeaux SRV30006677 Ebony SRV30003...

Страница 29: ...el number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Warming Shelf Kit Classic Black 0000200 Biscuit 0000205...

Страница 30: ...ing patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pertinent information for your heating appliance D...

Отзывы: