Congratulations on your choice of a Vermont Castings Encore® Model 2040-CAT-C Wood Burning Stove. At Vermont Castings
we take American craftsmanship seriously. We assure you that your cast-iron Vermont Castings stove has been made with
the utmost care and will provide you with many years of service.
As you become acquainted with your new stove, you will find that its appearance is matched by its functionality, due to cast
iron’s unique ability to absorb and radiate heat.
Also, Vermont Castings products are among the cleanest-burning wood stoves available today. However, clean burning
depends on both the manufacturer and the operator. Please read this manual carefully to understand how to properly operate
and maintain your stove.
At Vermont Castings, we are committed to your satisfaction as a customer. That is why we maintain an exclusive network of
the finest dealers in the industry. Our dealers are chosen for their expertise and dedication to customer service. Feel free to
contact your Authorized Vermont Castings Dealer anytime you have a particular question about your stove or its performance.
This manual contains valuable instructions on the operation of your Vermont Castings Encore® Model 2040-CAT-C Wood
Burning Stove. It also contains useful information on maintenance. Please read the manual thoroughly and keep it as a
reference.
This heater meets the U.S. Environmental Protection
Agency’s emission limits for wood heaters sold on or after
May 15, 2020.
Please read this entire manual before you operate your new
stove. Failure to follow instructions may result in property
damage, bodily injury, or even death.
Proposition 65 Warning:
Fuels used in gas, wood
burning or oil fired appliances, and the products of
combustion of such fuels, contain chemicals known to
the State of California to cause cancer, birth defects and
other reproductive harm.
California Health & Safety Code Sec. 25249.6
Report #/Rapport #
0135WS042E / 0135WS042S
Tested to / Testé à:
ASTM E2515, ASTM E2780, UL 1482-2011, ULC-S627-00, CAN/CSA B415.1
APPROVED FOR USE IN MOBILE HOMES IN THE U.S. AND CANADA.
Install and use only in accordance with manufacturer’s installation and operation instructions. Contact
local building or fire officials about restrictions and installation inspection in your area. Install only with
legs provided in accordance with installation instructions.
WARNING:
Risk of flame and smoke spillage. Do not obstruct the space beneath the heater.
Fuel:
Use with solid wood fuel only. Do not burn other fuels. Build a fire directly on hearth only. Do not
elevate fire. Keep doors fully closed while operating.
Chimney:
Use a minimum 6” or 8” diameter factory built high temperature (H.T.) chimney which is listed
to UL-103 (2100° F) or 8” X 8” nominal or larger approved masonry chimney with flue liner. Inspect
and clean chimney frequently - under certain conditions of use, creosote buildup may occur rapidly.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE
Chimney Connector: Use a minimum 6” or 8” diameter 24 gauge chimney connector. Install chimney
connector at least 30” from ceiling. Refer to local building codes and Vermont Castings Owner’s Guide
for special precautions for passing a chimney or chimney connector through a combustible wall or
ceiling.
Floor Protection:
The Encore does not require R value floor protection. The minimum floor protector
material is 20 gauge sheet metal. Other floor protector materials that can be used include: Type I
hearth pads, ceramic tile, stone, brick, etc. Protection requirements vary somewhat between the
Untied States and Canada.
Optional Components:
Flue Collar/8” oval Part No. 0555, Mobile Home Kit-0336, Fan Kit Part No.
FK26. 115V 60Hz 1.1 FLA
Replace glass only with Vermont Castings 5mm ceramic glass.
Do not remove or cover this label.
Catalytic Combustor Part No. 30006623
CAUTION:
Burning of materials other than the specified fuels may make the Catalyst in the combustor
inactive. The combustor is fragile, handle carefully.
Combustion air cannot be obstructed. Damper must be open before opening doors. Do not overfire.
Glowing parts indicate overfiring.The space heater must be installed with the legs provided,
attached as shown in the installation instructions.
BARCODE LABEL
HF
Serial No.
N
o
de série:
3-90-30007511_R1
Date of Manufacture / Date de fabrication:
2019 2020 2021 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
US ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 US EPA particulate emissions standards at
1.1 g/hr. This wood heater contains a catalytic combustor which needs
periodic inspection and replacement for proper operation. Consult the
Owner’s Manual for further information. It is against Federal Regulations
to operate this wood heater in a manner inconsistent with operating
instructions in the Owner’s Manual.
MODEL / MODÈLE: “Encore
®
Model 2040-CAT-C”
LISTED SOLID FUEL ROOM HEATER BURNING FIREPLACE STOVE
HOMOLOGUE POELE A COMBUSTIBLE SOLIDES
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION / MINIMUM DE DEGAGEMENT
JUSQU’A LA CONSTRUCTION COMBUSTIBLE
Installez et utilisez uniquement conformément aux instructions d’installation et d’utilisation du
fabricant. Contactez les responsables locaux de la construction ou les services d’incendie
pour connaître les restrictions et l’inspection de l’installation dans votre région. Installez
uniquement avec les pieds fournis conformément aux instructions d’installation.
Avertissement:
Risque de flammes et de fumée. Ne pas obstruer l’espace sous le radiateur.
Combustible:
Utilisez uniquement du combustible à bois solide. Ne brûlez pas d’autres
combustibles. Construire un feu directement sur le foyer seulement. Ne pas élever le feu.
Gardez les portes complètement fermées pendant le fonctionnement.
Cheminée:
Utilisez une cheminée haute température (H.T.) construite en usine et d’un
diamètre minimum de 6 ”ou 8”, qui est homologuée UL-103 (2100 ° F) ou une cheminée
en maçonnerie nominale ou supérieure approuvée de 8 ”X 8” avec conduit de cheminée.
Inspectez et nettoyez fréquemment la cheminée - dans certaines conditions d’utilisation, une
accumulation de créosote peut se produire rapidement.
Ne connectez pas cet appareil à un conduit de cheminée desservant un autre appareil
Raccord de cheminée:
Utilisez un raccord de cheminée de calibre 24 minimum de 6 ”ou 8”
de diamètre. Installez le raccord de cheminée à au moins 30 po du plafond. Reportez-vous
aux codes du bâtiment locaux et au Guide du propriétaire de Vermont Castings pour connaître
les précautions particulières à prendre pour faire passer une cheminée ou un connecteur de
cheminée à travers un mur ou un plafond inflammable.
Protection de sol:
Encore ne nécessite pas de protection de plancher de valeur R. Le
matériau de protection de plancher minimum est une tôle de calibre 20. Parmi les autres
matériaux de protection de sol pouvant être utilisés, citons: les coussinets de foyer de type I,
les carreaux de céramique, la pierre, la brique, etc.
Composants facultatifs:
collier de cheminée / ovale de 8 po (réf. 0555), kit pour maison
mobile-0336, kit de ventilateurs (réf. FK26). 115V 60Hz 1.1 FLA
Remplacez le verre uniquement par du verre en céramique de 5 mm Vermont Castings.
Ne pas enlever ni recouvrir cette étiquette. Système de combustion catalytique N ° de pièce
30006623
Attention:
La combustion de matériaux autres que les carburants spécifiés peut rendre le
catalyseur dans la chambre de combustion inactif. La chambre de combustion est fragile,
manipulez-la avec précaution.
CAUTION:
HOT WHILE IN OPERATION- DO
NOT TOUCH- KEEP CHILDREN AND CLOTHING AWAY-
CONTACT MAY CAUSE SKIN BURNS- SEE NAMEPLATE
AND INSTRUCTIONS. KEEP FURNISHINGS AND
OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE
DISTANCE AWAY FROM THE APPLIANCE
ATTENTION:
CHAUD LORS
DU FONCTIONNEMENT- NE TOUCHEZ
PAS L’APPAREIL-GARDEZ LES ENFANTS ET LES
VÊTEMENTS ÉLOIGNÉS- TOUT CONTACT PEUT
ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-
VOUS À LA PLAQUE SIGNALÉTIQUE ET AU MODE
D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES
MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE
L’APPAREIL.
*Less than 3/4” (19mm) protrusion. For additional types of installations and clearances consult your
Owner’s Manual. Por autres modes d’installation et degagement supplementaires, consultz votres
manual du proprietaire.
Most vertical installations require a ceiling heat shield and a flue collar heat shield to be installed.
Consult your Owner’s Manual.
A
= Unit to Sidewall
19”
B
= Unit to Backwall
20”
C
= Chimney Connector to Sidewall 29”
D
= Chimney Connector to Backwall 21”
E
= Unit to Adjacent Wall
18-1/2”
F =
Sides (Floor Protection)
6”
G =
Front to Glass (Floor Protection) 16”
H =
Rear (Floor Protection)
6”
I =
Top to Bottom of Mantel
22”
J =
Top to Bottom of Top Trim*
28”
K =
Edge of Top to Side Wall
21”
A
= Entre le mur lateral et l’appareil
483mm
B
= Entre le mur arriereet l’appareil
508mm
C
= Entre le tuyau et le mur lateral
737mm
D
= Entre le tuyau et le mur arriere
534mm
E
= Entre le mur adjacent et l’appareil
470mm
F =
Côtes (la protection de plancher)
203mm
G =
Devant, par rapport au verr
457mm
H =
Arrière (la protection de plancher)
203mm
I =
De haut en bas de Mantel
556mm
J =
De haut en bas de la moulure supérieure*
712mm
K =
Edge of Haut de paroi latérale
534mm
E
E
A
B
C
D
G
F
H
F
J
K
I
MINIMUM FLOOR
PROTECTION
HEARTH
INSTALLATION
Made in U.S.A. of US and imported parts.
Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.
LABEL TICKET
ECO:
89484
LABEL SIZE:
4.75” H x 15.75” W
PART # / REV:
3-90-30007511
ADHESIVE:
ORIGINATOR:
Spidlet
MATERIAL:
24 Gauge Aluminum
DATE:
03/05/19
INK:
Black Background
ALL CAUTION LITERATURE IN RED
(4) Holes = .156 x .250, Corners .062
Barcode label must have the serial number on it. The
barcode label must be able to read Code 39 Full ASCII.
352 Mountain House Road
Halifax, PA 17032
Serial No.
S A
M P
L E
Test Lab & Report No.
Model Name
Mfg. Date