background image

6

Encore

®

 1450CE Non-Catalytic Woodburning Stove

30003845

1.  Not interchangeable, due to a heat-reflective coating on the room 

side of the panels.

.  Included in #0004345 ceramic handle assembly.

encore woodburning Stove

model 1450ce (continued)

 

  item description 

part Number

 

  item description 

part Number

 

1.  Flue Collar (8”) 

See Chart Pg. 33

 

.  Inner Back 

3000385

 

3.  Left Heat Deflector 

3000441

 

4.  Right Heat Deflector 

300044

 

5.  Left Griddle Quad 

3000399

 

6.  Right Griddle Quad 

3000401

 

7.  Griddle 

3000386

 

8.  Griddle Handle Assy 

3000775

 

9.  Top 

See Chart Pg. 33

  10.  Damper Housing 

3000413

  11.  Damper 

3000389

  1.  Damper Tabs (3) 

1601488

  13.  Damper Rod 

1600851

  14.  Damper Handle Screw 1/4-0 x 3

³⁄₈

” NT 

101310

  15.  Damper Handle,Wood  

1600664

  16.  Steel Handle Stub 

300070

  17.  Left Side 

See Chart Pg. 33

  18.  Left Air Manifold (Inner side) 

3000408

  19.  Right Air Manifold (Inner side) 

3000409

  0.  Right Side 

See Chart Pg. 33

  1.  Thermostat Handle Shaft w/set screw 

3000716

 1a.  Thermostat Handle Wood 

1600660

 1b.  Round Hd, Sl 8-3 x  Screw 

10143

  .  Grate 

3000390

  3.  Bottom Outer 

3000391

  4.  Ashlip 

See Chart Pg. 33

  5.  Andiron () 

3000397

  6.  Leg 

See Chart Pg. 33

  7.  Leg Leveler 

101745

  8.  Pawl Assembly Short Adjustment 

300036

  9.  Ashdoor 

300039

  30.  Ashdoor Handle (Wood) 

1600663

  31.  Ashdoor Hinge Pin 

3000473

  3.  Cotter Pin, Ashdoor 

30001749

  33.  Ashdoor Hinge Lower 

3000404

  34.  Ashpan 

160105

  35.  Ashpan Bracket 

1601039

  36.  Ashpan Cover 

160107

  37.  Airwash Manifold 

3000407

  38.  Front 

See Chart Pg. 33

  39.  Left Door 

See Chart Pg. 33

  40.  Door Hinge Strip () 

1308634

  41.  Right Door 

See Chart Pg. 33

  4.  Door Gasket 5/16 Med. Density 6ND 

103588

  43.  Glass Gasket 

103556

  44.  Left Door Glass

1

 

3000476

  45.  Right Door Glass

1

 

140869

  46.  Spacer 3/8 x 1-Z  

101779

  47.  Damper Ramp 

1301811 

 

 

  Socket Set Screw Adjuster 

100436 

 

 

  PH Flat Hd Screw 

100809 

 

 

  Hex Nuts 

10310

  48.  Handle Base Stub

 

3000714

  49.  Ceramic Handle .78 Lg

 

0006381

  50.  Handle Bolt

 

10194

  51.  Friction Spring 

101846

  5.  Washer 

10471

  53.  Pin, Long, Door 

300077

  54.  Inner Bottom 

3000406

  55.  Primary Air Plate 

3000415

  56.  Lower Brick Retainer 

3000416

  57.  Hinge, Upper Ashdoor 

3000403

  58.  Fountain Assembly CDW  

3000100

  59.  Insul Gasket Shoe 

3000418

  60.  Refractory Shoe 

3000419

  61.  Refractory Lower 

3000414

  6.  End Insulation 

300040

  64.  Right End Refractory 

300041

  65.  Left End Refractory 

3000475

  66.  Primary Air Flap 

3000443

  67.  Primary Air Shaft 

3000841

  68.  Primary Air Linkage 

3000445

  69.  Outer Back Assembly 

3000450

  70.  Bottom Heat Shield 

3000446

  71.  Griddle Gasket 

103668

  7.  Rear Side Bracket 

3000457

  73.  Brick Support Bracket 

3000480

  74.  Holder, Door Handle 

3000909

  75.  Front Steel Handle w/Shaft 

3000717

  76.  Ashdoor Handle Shaft 

16006

  77.  Hex Jam Nut 

10390

  78.  Bracket, Upper Side 

3000667

  79.  Rheostat Bracket 

3000863

  80.  Fountain Heatshield 

3000457

Содержание Encore 1450C

Страница 1: ...the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local building officials about restrictions and...

Страница 2: ...Vermont Castings stove It also contains useful information on maintenance and assembly of this product We urge you to read the manual thoroughly and to keep it as a reference Sincerely All of us at MH...

Страница 3: ...r 8 oval flue collar 203 mm 8 diameter for optional 6 flue collar 152 mm 6 diameter Chimney flue size for 8 oval flue collar 203 mm 8 minimum for optional 6 flue collar 152 mm 6 minimum Flue exit posi...

Страница 4: ...low all instructions exactly and do not allow makeshift com promises to endanger property and per sonal safety All local regulations including those referring to national and European standards need t...

Страница 5: ...6 and be of the twin wall insulated construction that has been approved for solid fuel use e g Rite Vent ICS of ICID Lite Chimney Systems Diameters over 200 mm 8 are not recommended due to the large...

Страница 6: ...on of chimney connec tor serve as guides when you drill 3 mm 1 8 holes in the bottom of the next section Secure the chimney connector to the chimney In structions for various installations follow Be s...

Страница 7: ...mble sleeve should protrude 25 51 mm 1 2 into the room Fig 6 Use furnace cement and thin gasketing to seal the sleeve in place in the thimble Secure the chimney connector to the outer end of the sleev...

Страница 8: ...675 mm 26 you may install an Encore through the opening using a positive connection kit available from your lo cal dealer These positive connection kits ensure a tight fit between the stove flue colla...

Страница 9: ...clearances of the hearth are as fol lows The constructed hearth should be constructed in ac cordance with the recommendations in document J and should be of minimum width 840 mm and minimum depth 840...

Страница 10: ...o any combustible surfaces e g wooden mantels or lintels and to timber framed studded walls even if they are faced with noncombustible board Detailed information on fireplace and hearth construction i...

Страница 11: ...ces and Fuel Storage Systems This can be achieved by following the recommenda tions of Approved Document J These are as shown in Figure 13 34 FLUEPIPE CLEARANCES D at least 3 x D Elevation Without Shi...

Страница 12: ...no weight on the leg while making the adjustment Reverse the Flue Collar If Necessary Reverse the flue collar by removing the two 2 screws that attach it to the back of the stove Be sure the gas ket...

Страница 13: ...ided with stove under the right wing of the bottom heat shield with two 2 10 sheet metal screws 5 Attach the rheostat to its holder by inserting the rheostat control shaft through the holder hole Inst...

Страница 14: ...Andirons ST636 Fig 19 The Encore controls are conveniently located and easy to operate Door Handle A Single Air Control Regulates Heat Output and Burn Time The primary air control lever located on th...

Страница 15: ...d is their density Hardwoods because of their greater density burn longer than softwoods and can increase the time between refuelings Store wood under cover to keep it dry The longer it is stored in a...

Страница 16: ...far right to 1 3 the distance to left Medium From 1 3 to 2 3 the distance to left High From 2 3 the distance to left to far left DO NOT OPERATE THE STOVE WITH THE ASH DOOR OPEN OPERATION WITH THE ASH...

Страница 17: ...nclude some smaller pieces of wood in the new fuel load to help the stove regain its operating temperature quickly Use this sequence as a guide to successful refueling NOTE Door handles can be hot A g...

Страница 18: ...lly dispersed it should be kept in the closed container until all cinders have thoroughly cooled You can use wood ash as a garden fertilizer CAUTION Never use your household or shop vacuum cleaner to...

Страница 19: ...at heat from the chimney walls will transfer to the house and not be wasted outdoors An indoor chimney will not lose its heat to the outdoors so Draft Management it takes less heat from the stove to h...

Страница 20: ...voiding overly dry wood loaded into a very hot stove may help this problem If back puffing persists contact your dealer or qualified chimney sweep to help diag nose the problem Draft Testing An easy w...

Страница 21: ...not use abrasive cleaners Rinse the glass thoroughly Dry the glass completely Replace Broken Glass Immediately Do not operate your stove if the glass in the doors is damaged If you need to replace th...

Страница 22: ...an end and pulling firmly 2 Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement or bits of gasket Fig 32 Remove stubborn deposits of cement with a cold chisel if...

Страница 23: ...cantly However regular chimney inspection and maintenance must still be performed For safety good stove performance and to protect your chimney and chimney connector inspect your chimney and chimney c...

Страница 24: ...and remove ash build up behind the com bustion package This should be done in conjunction with annual cleaning of the chimney connector since this inspection is most conveniently done through the flu...

Страница 25: ...64 62 19 56 60 59 22 56 58 54 23 25 48 49 50 45 53 42 41 53 24 28 57 26 27 38 18 17 14 16 46 65 62 44 43 40 39 34 35 70 33 31 32 30 28 42 29 15 71 36 5 6 75 76 77 77 78 27 80 MHSC reserves the right...

Страница 26: ...er Pin Ashdoor 30001749 33 Ashdoor Hinge Lower 30002404 34 Ashpan 1601025 35 Ashpan Bracket 1601039 36 Ashpan Cover 1601027 37 Airwash Manifold 30002407 38 Front See Chart Pg 33 39 Left Door See Chart...

Страница 27: ...0002633 30002623 30002643 30003082 Right Side 30003053 30002612 30004877 30003063 30003073 30002632 30002622 30002642 30003083 Flue Collar 30003008 2324280 30004868 30003020 30003032 2374280 1324280 3...

Страница 28: ...d wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to th...

Отзывы: