good fire
12/99

ST64

fig. 25

  Add larger pieces of wood as the fire begins to burn 

well.

Once the draft is established, open the front door and 
light the rest of the fuel from the bottom.  Do not light 
the main bed of fuel until the chimney begins drawing, 
and repeat the procedure as often as necessary if the 
initial attempt is unsuccessful.
If your Encore has been broken-in previously using, 
continue to build the fire gradually. Add larger wood with 
a diameter of 76-10 mm (3-4”).  Continue adding split 
logs of this size to the briskly-burning fire until there is 
a glowing ember bed  at least 76 mm (3”) deep. A good 
ember bed is necessary for proper functioning of the 
combustion system and may take an hour or more to 
establish.  

refuel while the embers are Still hot

When reloading, best results will be achieved if you first 
de-ash the stove by stirring the fuel bed to allow ash to 
fall through the grate into the ash pan.
Do not break the charcoal into very small pieces or 
pound or compress the charcoal bed.
It is important that air can circulate through the charcoal 
bed while the heater is in operation. Larger pieces of 
charcoal allow more air to circulate under the wood,  
resulting in the fire reviving more quickly.
For best results when refueling, wear stove gloves to 
protect your hands, add fuel while the stove still has 

ST264a
add wood fire
11/00

ST64a

fig. 26 

 Add full-size logs when the kindling has burned down 

to a bed of embers.

plenty of glowing embers to re-kindle the fire, and 
include some smaller pieces of wood in the new fuel 
load to help the stove regain its operating temperature 
quickly.  Use this sequence as a guide to successful 
refueling. 

Note:

 Door handles can be hot. A glove has been 

included with your stove. We recommend using this 
glove whenever operating door or damper controls and 
especially when operating the top griddle.
1.  Open the damper.
.  De-ash the stove as described above. Open the 

front doors and check the level of ash in the ash 
pan. Empty the pan if necessary and replace it in the 
stove. Close the front doors.

3.  Open the griddle, load the wood (smaller pieces 

first), and close the griddle.

4.  Allow the stove to regain its “thermal momentum” 

before closing the damper. This may take 15--0 
minutes.

5.  Close the damper and set the air control lever for the 

desired heat output. When the surface temperature 
reaches 30° C (450° F), adjust the air control for 
the amount of heat you desire.

Note:  

If the charcoal bed is relatively thick {about 51-

76 mm (”-3”)} deep, and if your fuel is well seasoned, it 
is possible to add fresh fuel (smaller pieces first), close 
the door and damper, and reset the primary air control 
for the desired heat output within five minutes.

warNiNg:  fireplace StoveS equipped with 
doorS Should be operated oNly with 
doorS fully opeN or doorS fully cloSed. 
if doorS are left partly opeN, gaS aNd 
flame may be drawN out of the fireplace 
Stove opeNiNg creatiNg riSkS from both 
fire aNd Smoke.
cautioN:  the encore will be hot while in opera-
tion.  keep children, clothing and furniture away.  
contact may cause skin burns.

do Not overfire thiS heater.

  Overfiring may 

cause a house fire, or can result in permanent dam-
age to the stove and to the catalytic combustor.  If 
any part of the Encore glows, you are overfiring.

Содержание Encore 1450C

Страница 1: ...the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local building officials about restrictions and...

Страница 2: ...Vermont Castings stove It also contains useful information on maintenance and assembly of this product We urge you to read the manual thoroughly and to keep it as a reference Sincerely All of us at MH...

Страница 3: ...r 8 oval flue collar 203 mm 8 diameter for optional 6 flue collar 152 mm 6 diameter Chimney flue size for 8 oval flue collar 203 mm 8 minimum for optional 6 flue collar 152 mm 6 minimum Flue exit posi...

Страница 4: ...low all instructions exactly and do not allow makeshift com promises to endanger property and per sonal safety All local regulations including those referring to national and European standards need t...

Страница 5: ...6 and be of the twin wall insulated construction that has been approved for solid fuel use e g Rite Vent ICS of ICID Lite Chimney Systems Diameters over 200 mm 8 are not recommended due to the large...

Страница 6: ...on of chimney connec tor serve as guides when you drill 3 mm 1 8 holes in the bottom of the next section Secure the chimney connector to the chimney In structions for various installations follow Be s...

Страница 7: ...mble sleeve should protrude 25 51 mm 1 2 into the room Fig 6 Use furnace cement and thin gasketing to seal the sleeve in place in the thimble Secure the chimney connector to the outer end of the sleev...

Страница 8: ...675 mm 26 you may install an Encore through the opening using a positive connection kit available from your lo cal dealer These positive connection kits ensure a tight fit between the stove flue colla...

Страница 9: ...clearances of the hearth are as fol lows The constructed hearth should be constructed in ac cordance with the recommendations in document J and should be of minimum width 840 mm and minimum depth 840...

Страница 10: ...o any combustible surfaces e g wooden mantels or lintels and to timber framed studded walls even if they are faced with noncombustible board Detailed information on fireplace and hearth construction i...

Страница 11: ...ces and Fuel Storage Systems This can be achieved by following the recommenda tions of Approved Document J These are as shown in Figure 13 34 FLUEPIPE CLEARANCES D at least 3 x D Elevation Without Shi...

Страница 12: ...no weight on the leg while making the adjustment Reverse the Flue Collar If Necessary Reverse the flue collar by removing the two 2 screws that attach it to the back of the stove Be sure the gas ket...

Страница 13: ...ided with stove under the right wing of the bottom heat shield with two 2 10 sheet metal screws 5 Attach the rheostat to its holder by inserting the rheostat control shaft through the holder hole Inst...

Страница 14: ...Andirons ST636 Fig 19 The Encore controls are conveniently located and easy to operate Door Handle A Single Air Control Regulates Heat Output and Burn Time The primary air control lever located on th...

Страница 15: ...d is their density Hardwoods because of their greater density burn longer than softwoods and can increase the time between refuelings Store wood under cover to keep it dry The longer it is stored in a...

Страница 16: ...far right to 1 3 the distance to left Medium From 1 3 to 2 3 the distance to left High From 2 3 the distance to left to far left DO NOT OPERATE THE STOVE WITH THE ASH DOOR OPEN OPERATION WITH THE ASH...

Страница 17: ...nclude some smaller pieces of wood in the new fuel load to help the stove regain its operating temperature quickly Use this sequence as a guide to successful refueling NOTE Door handles can be hot A g...

Страница 18: ...lly dispersed it should be kept in the closed container until all cinders have thoroughly cooled You can use wood ash as a garden fertilizer CAUTION Never use your household or shop vacuum cleaner to...

Страница 19: ...at heat from the chimney walls will transfer to the house and not be wasted outdoors An indoor chimney will not lose its heat to the outdoors so Draft Management it takes less heat from the stove to h...

Страница 20: ...voiding overly dry wood loaded into a very hot stove may help this problem If back puffing persists contact your dealer or qualified chimney sweep to help diag nose the problem Draft Testing An easy w...

Страница 21: ...not use abrasive cleaners Rinse the glass thoroughly Dry the glass completely Replace Broken Glass Immediately Do not operate your stove if the glass in the doors is damaged If you need to replace th...

Страница 22: ...an end and pulling firmly 2 Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement or bits of gasket Fig 32 Remove stubborn deposits of cement with a cold chisel if...

Страница 23: ...cantly However regular chimney inspection and maintenance must still be performed For safety good stove performance and to protect your chimney and chimney connector inspect your chimney and chimney c...

Страница 24: ...and remove ash build up behind the com bustion package This should be done in conjunction with annual cleaning of the chimney connector since this inspection is most conveniently done through the flu...

Страница 25: ...64 62 19 56 60 59 22 56 58 54 23 25 48 49 50 45 53 42 41 53 24 28 57 26 27 38 18 17 14 16 46 65 62 44 43 40 39 34 35 70 33 31 32 30 28 42 29 15 71 36 5 6 75 76 77 77 78 27 80 MHSC reserves the right...

Страница 26: ...er Pin Ashdoor 30001749 33 Ashdoor Hinge Lower 30002404 34 Ashpan 1601025 35 Ashpan Bracket 1601039 36 Ashpan Cover 1601027 37 Airwash Manifold 30002407 38 Front See Chart Pg 33 39 Left Door See Chart...

Страница 27: ...0002633 30002623 30002643 30003082 Right Side 30003053 30002612 30004877 30003063 30003073 30002632 30002622 30002642 30003083 Flue Collar 30003008 2324280 30004868 30003020 30003032 2374280 1324280 3...

Страница 28: ...d wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to th...

Отзывы: