8

10009285

Remove Screws

Fig. 6 Remove screws that hold refractory bracket with
ember bed.

Depending on your model, the fireplace uses two (2) or
three (3) clear 120 Volt, 60 Watt, E-12 socket base
light bulbs (small base, chandelier candle type) located
under the ember bed. Units with overhead lights (Fig.
9) use two (2) clear 120 Volt, 5 Watt, E-12 socket base
light bulbs (small base, chandelier candle type) located
above the logs. For convenience, if one of the light
bulbs burns out, it may be easier to replace all of the
light bulbs at the same time.

Do not exceed 60 Watts per bulb for the
ember bed bulbs and 5 Watts per bulb for
the overhead lights. Use of higher rated
bulbs may result in a fire, causing proper-
ty damage, personal injury or loss of life.

1. Turn off power to the unit.

2. Let fireplace cool if it has been operating.

3. Open the front doors.

4. Locate two (2) screws that hold the refractory (brick

patterned) bracket together with the ember bed.
(Fig. 6)

5. Remove those two (2) screws using an appropriate

screwdriver. One screw is located on either side of
the unit.

Replacing the Light Bulbs

Pull Here
(both sides)

Fig. 7 Pull ember bed out of unit.

6. Pull the ember bed out of the unit, by gently pulling

towards you and only slightly upwards. Depending
on the model, you can remove the refractory prior
to removing the ember bed.

7. Looking into the opening of the unit under the

ember bed, visually locate the light bulbs.

8. Remove the light bulbs by unscrewing them out of

the bases, turning them counterclockwise. You can
use one hand to hold the light socket in place, if
required.

60 W Light Bulbs

Fig. 8 Remove and replace light 60 W bulb(s).

9. Install the new light bulb(s) by turning the light bulb

into the base clockwise. You can use one hand to
hold the light socket in place, if required.

10.Reposition the ember bed. If required, gently raise

the refractory panels, one at a time, to tuck the
ember bed edge underneath them.

11.Reposition the refractory bracket, aligning the

refractory in place as required.

12.Reinstall the two (2) screws removed in Step 5.

5 W Light Bulb

Fig. 9 Remove and replace 5 W bulb(s).

Содержание EFGM5F0

Страница 1: ...BEFORE INSTALLING AND USING APPLIANCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE F...

Страница 2: ...hazard and will void the warranty Installation Instructions General 3 Locating Your Fireplace 3 Clearance to Combustibles 3 Cabinet Installations 3 Fireplace Dimensions 4 Electrical Specifications 4...

Страница 3: ...ny other use not recommended by the manufacturer may cause fire electric shock or injury to persons 18 Avoid the use of an extension cord because of the risk of overheating the cord and the risk of fi...

Страница 4: ...2 mm 11 292 mm 11 292 mm F 18 457 mm 25 635 mm 28 711 mm G 25 641 mm 32 819 mm 35 895 mm H 19 495 mm 22 578 mm 26 667 mm J 31 787 mm 36 916 mm 38 971 mm K 43 1114 mm 51 1295 mm 54 1373 mm L 21 557 mm...

Страница 5: ...or fuse in the electrical panel of the dwelling The cable between the circuit fuse panel and the fireplace must meet all local and national codes and in no case shall the wires be less than 14 gauge 1...

Страница 6: ...Using a wire nut connect the hot lead black of the power cable to the power cord wire that ends in 90 terminal on the control board side it ends on your right hand side Similarly connect the neutral...

Страница 7: ...he front cover holding both sides of the cover pull gently towards you and down Fig 5 Hold both sides and pull gently forward and down 7 You now have access to the heater fan unit for cleaning and or...

Страница 8: ...6 5 Remove those two 2 screws using an appropriate screwdriver One screw is located on either side of the unit Replacing the Light Bulbs Pull Here both sides Fig 7 Pull ember bed out of unit 6 Pull t...

Страница 9: ...leaning Cleaning of the touchpad label at the bottom front of the unit is to be done only using a soft cloth slightly dampened in water if needed a small amount of dish soap can be added to the water...

Страница 10: ...lame effect is off This mode allows you to use your fire place as an electric heater without any flame effect Refer to Figures 10 11 for locations of the buttons on both the touchpad and remote contro...

Страница 11: ...increase the room temperature depress button 6 to increase room temperature set ting When the set temperature is reached the heater will automatically cycle on and off to maintain the tem perature set...

Страница 12: ...0009238 10009239 3 Circuit Board 10009626 10009626 10009626 4 Refractory Right side 10009198 10009199 10009202 5 Refractory Left Side 10009198 10009200 10009201 6 DC Motor 10009621 10009621 10009621 7...

Страница 13: ...13 10009285...

Страница 14: ...14 10009285...

Страница 15: ...le price of the defective part s 6 Any installation labor construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be...

Страница 16: ...CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com...

Отзывы: