30
Defiant Woodburning Stove
30003841
Appendix: Chimney and Fireplace Hazards
General -
A. Improper chimney height. The top of the chimney
must be at least 914 mm (36”) higher than the spot
where it passes through or past the roof, or two feet
higher than everything else within ten feet horizon-
tally, whichever is higher.
B. Deteriorated chimney cap
C. Structural defects indicated by creosote stains on
outside of chimney
D. Blockage within chimney
E. Improper clearance between chimney and nearby
combustibles (less than 51 mm (2”) - check local
codes)
K. Loose or leaky cleanout door
For a fireplace -
F. Improper clearance between smoke chamber and
framing materials - (less than 51 mm (2”) - check
local codes)
G. Creosote buildup on smoke shelf
H. Structural deterioration
I. Loose or broken bricks or mortar
J. Insufficient hearth depth. The hearth must extend
406 mm (16”) beyond the fireplace opening. With
a fireplace insert, or a free-standing stove vented
through a fireplace, the hearth must extend 406 mm
(16”) beyond the front door opening of the stove or
insert.
A
B
C
E
D
F
G
H
I
J
H
K
ST562
Chimney hazards
12/14/00 djt
ST562
Содержание Defiant 1945CE
Страница 34: ...34 Defiant Woodburning Stove 30003841...