background image

17

Defiant Woodburning Stove

30003841

To determine whether the combustor is operating, ob-
serve the amount of smoke leaving the chimney when 
the damper is activated and when it is not. This proce-
dure is described on Page 29.
Avoid using a full load of very dry wood in the firebox.  
This may result in continuous very high temperatures 
in the secondary combustion area and damage the 
combustor. Wood which has been split, and stored un-
der cover for more than 18 months may be considered 
very dry.  If you must burn extra-dry wood, mix it with 
greener wood for a longer fire and less stress on the 
combustor. Also, do not use a full load of dry slab wood 
or scrap wood. For long burns, use a mix of dry and 
moderately dry wood.  

Conditioning Your Stove

Cast iron is extremely strong, but it can be broken with 
a sharp blow from a hammer or from the thermal shock 
of rapid and extreme temperature change.
The cast plates expand and contract with changes in 
temperature. When you first begin using your Defiant, 
minimize thermal stress by letting the plates adjust 
gradually during three or four initial break-in fires follow-
ing Steps 1-3 below.

Starting and Maintaining a Wood Fire

Burn only solid wood in the Defiant, and burn it directly 
on the grate. Do not elevate the fuel. Do not burn coal 
or other fuels. 
The damper must be open when starting a fire or when 
refueling.  

Do not use chemicals or fluids to start the fire.  Do 
not burn garbage or flammable fluids such as gaso-
line, naphtha, or engine oil. 

1.  Open the stove damper, and open the primary air 
control fully.
2.  Place several sheets of crumpled newspaper in the 
stove.  Do NOT use glossy advertisements or colored 
paper, as they can poison the catalyst. Place on the 
paper six or eight pieces of dry kindling split to a finger-
width size, and on the kindling lay two or three larger 
sticks of split dry wood approximately 25-50 mm (1-2”) 
in diameter. (Fig. 26)
Also, never use gasoline-type lantern fuel, kerosene, 
charcoal lighter fluid, or similar liquids to start or “fresh-
en up” a fire.  Keep all such liquids well away from the 
Defiant while it is in use.

3.

  Light the newspaper and close the door.  Gradually 

build up the fire by adding a few 76-127 mm (3-5”) di-
ameter splits.  

If this is one of the first few “break-in” 

fires, let the fire burn brightly, and then let it die out. 

 

During the break-in fires, do not let the stove get hot-
ter than 260° C (500° F) as measured on an optional 

ST263

starting a fire

12/99

ST263

Fig. 26

  Start the fire with newspaper and dry kindling.

stove-top thermometer.  Adjust the air control lever as 
necessary to control the fire.
Some odor from the stove’s hot metal, the paint, and 
the cement is normal for the first few fires.

NOTE:

  Some chimneys must be “primed,” or warmed 

up, before they will draw sufficiently to start a fire.  To 
correct this situation, roll up a couple pieces of news-
paper, place them on top of the kindling and toward 
the back of the stove, light them, and close the doors.  
This will encourage the smoke to rise rapidly, making it 
easier to establish a good draft.  
Once the draft is established, open the front door and 
light the rest of the fuel from the bottom.  Do not light 
the main bed of fuel until the chimney begins drawing, 
and repeat the procedure as often as necessary if the 
initial attempt is unsuccessful.

4.

  

If your Defiant has been broken-in previously 

us-

ing Steps 1-3, continue to build the fire gradually.  Add 
larger wood with a diameter of 76-102 mm (3-4”100). 
Continue adding split logs of this size to the briskly-
burning  fire until there is a glowing ember bed  at least 
76 mm (3”) deep. (Fig. 27) A good ember bed is neces-
sary for proper functioning of the catalytic system and 
may take an hour or more to establish.  

5.

  Close the damper when the griddle temperature 

reaches 230° C (450° F).  

6.

  Adjust the air control for your desired heat output. 

NOTE:

 Stove installations vary widely, and the operat-

ing guidance given here is only a starting point . The 
draft management information on Page 20 will explain 
in detail how the features of your installation may help 
or hinder good draft, and how you may need to vary 
your firing technique if your installation doesn’t encour-
age a good draft. 

Refuel While the Embers Are Still Hot

When reloading, best results will be achieved if you first 
de-ash the stove by stirring the fuel bed to allow ash to 
fall through the grate into the ash pan.

Содержание Defiant 1945CE

Страница 1: ...INSTALLED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR...

Страница 2: ...of warmth beauty and comfort in your home At CFM Corporation we share that joy and appreciation for the hearth We assure you that your cast iron Vermont Castings stove has been made with the utmost c...

Страница 3: ...rior using new technologies for ef cient combustion Americans purchased over a quarter million De ants as they rediscovered the common sense of heating with wood a home grown fuel with none of the pol...

Страница 4: ...N T 826 mm 32 724 mm 28 788 mm 31 96 mm 3 546 mm 21 489 mm 19 464 mm 18 546 mm 21 3841 Defiant EU dimensions 7 06 768 mm 30 D E F I A N T 591 mm 23 489 mm 19 654 mm 25 C L 737 mm 29 Flue exit position...

Страница 5: ...ng a chimney or house re Follow all instruc tions exactly and do not allow makeshift compro mises to endanger property and personal safety All local regulations including those referring to national a...

Страница 6: ...t be operated with the front doors open Whatever the ue collar size an De ant may be vented into larger chimneys as well However chimneys with liners larger than 203 x 305 mm 8 x 12 may experience rap...

Страница 7: ...Flue Gas Direction Toward Stove ST242 Fig 4 Chimney connector ue collar with three 10 x 1 2 sheet metal screws Lift off the griddle and shield the stove s surface between the griddle opening and the...

Страница 8: ...above the replace opening Seal This Off ST243 thinble connection 12 13 99 djt Thimble Sleeve Chimney Connector Flue Keep sleeve end ush with ue tile ST243 Fig 6 The thimble made of either ceramic or...

Страница 9: ...NOT CONNECT THE DEFIANT TO ANY AIR DIS TRIBUTION DUCT OR SYSTEM ST245 fireplace flex connector 12 99 Flexible Connector Mantel Shield Fireplace Adapter Kit Positive Connection ST245 Fig 8 Through the...

Страница 10: ...De ant Costructional Hearth Dimensions as below At least 300 mm At least 150 mm or to a suitable heat resistant wall At least 150 mm Hearth Surface Free of Com bustible Material Perimeter should be c...

Страница 11: ...A Minimum distance from stove to movable combus tible materials e g furniture drying clothes etc 1220 mm 48 ST486a Defiant EU Clearance Diagrams 10 06 A B ST486a Fig 11 Minimum clearances D at least 3...

Страница 12: ...g the stove especially across rough surfaces can cause the legs to loosen or even break Storing the Handle Use the removable handle to open or close the doors After using it remove the handle so it wi...

Страница 13: ...ew to attach the damper handle to the damper stub on the left side Attach the Primary Air Thermostat Handle The primary air thermostat handle is the smaller of the two black handles Secure the handle...

Страница 14: ...e stove controls the amount of incoming air for starting maintaining and reviving a re More air entering the stove makes the re burn hotter and faster while less air prolongs the burn at a lower heat...

Страница 15: ...nd air dried outside under cover for at least one year If hardwood is not available you can burn softwoods that include tamarack yellow pine white pine East ern red cedar r and redwood These should al...

Страница 16: ...to get quite hot within a few minutes after a re is started the combus tor may stop working or the re may go out if the re dies down immediately as a result of the damper being closed Once the combus...

Страница 17: ...e it is in use 3 Light the newspaper and close the door Gradually build up the re by adding a few 76 127 mm 3 5 di ameter splits If this is one of the rst few break in res let the re burn brightly and...

Страница 18: ...sn t working Note that the catalyst is most likely to glow at its higher temperatures which it reaches when the rebox is in its lower range the catalyst is an after burner and the more waste fuel ther...

Страница 19: ...erial Return the ash pan to its original position in the stove and close and latch the ash door Fig 31 Do not operate the stove with the ash door open This will result in over ring and could cause dam...

Страница 20: ...the home An indoor chimney won t lose its heat to the outdoors so it takes less heat from the stove to heat it up and keep it warm Chimney Height The common wisdom tells us that a taller ue draws bet...

Страница 21: ...sture meters available for rewood you can also judge your wood by its appearance and weight If you get it green lift a piece and get a sense of its weight it can lose a third or more of its weight as...

Страница 22: ...crack a nearby window or door to enable the chimney to pull well that s a sign that you should install an outside air intake to bring combustion air directly to the stove An outside air adapter will a...

Страница 23: ...ss with water or a cleaner made espe cially for this purpose Do not use abrasive cleaners Use cleaning agents sparingly and be sure to keep them off the outer surfaces of the stove Rinse the glass tho...

Страница 24: ...he pressure screw from turning as you tighten the nut Re test the damper Tighten the Damper Handle as Needed A handle on the left side of the stove controls the damper The handle attaches to the dampe...

Страница 25: ...he stove damper and once again check the smoke leaving the chimney You should see signi cantly more smoke when the stove damper is open and exhaust does not pass through the combustor However be caref...

Страница 26: ...ing its effectiveness ST558 Inspect Catalytic element 4 11 00 Catalytic Ele ment Catalytic Access Panel ST558 Fig 38 Remove and inspect the catalytic element 5 Inspect the element for damage or degrad...

Страница 27: ...need periodic replacement The sizes of replaceable gasket are listed below along with their applications Gasket Diameter And the Parts it Seals 5 16 The griddle to the stove top wire reinforced gaske...

Страница 28: ...everyone out of the house Call the Fire Department Inspect the system every two weeks during the heat ing season as part of a regular maintenance schedule To inspect the chimney let the stove cool com...

Страница 29: ...alyst is still there it is covered or masked by the contaminant and cannot function To avoid this situation it is important not to burn any thing in your De ant that is a source of these contami nants...

Страница 30: ...roper clearance between chimney and nearby combustibles less than 51 mm 2 check local codes K Loose or leaky cleanout door For a replace F Improper clearance between smoke chamber and framing material...

Страница 31: ...9 85 86 87 70 78 71 88 59 90 52 91 91 CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice De ant...

Страница 32: ...rt 1300642 58 Ashpan Bracket 30001908 59 Primary Air Valve Assy 5000024 60 Primary Air Frame3 1307411 61 Primary Air Rod3 1600058 62 Primary Air Valve3 1307412 63 Thermostat Handle Wood 1600660 64 Air...

Страница 33: ...0001612 1320621 30001616 Suede Brown 30002578 30002574 30002573 30002575 30002583 30002580 Vermont Classic Green 30002997 30002993 30002992 30002994 30002991 30002998 Shell Enamel Parts De ant Enamel...

Страница 34: ...34 Defiant Woodburning Stove 30003841...

Страница 35: ...te 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This w...

Страница 36: ...CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: