background image

2

Defiant 1610CE Non-Catalytic Woodburning Stove

30003846

This manual describes the installation, operation, and maintenance of the Vermont Castings Defiant Model 1610CE 
non-catalytic wood burning heater.  This heater meets the U.S. Environmental Protection Agency’s emission limits for 
wood heaters sold on or after July 1, 1990.  Under specific test conditions this heater has been shown to deliver heat 
at rates up to 14.5 kW (49,500 BTU/hr).
The Defiant Model #1610CE has been tested to current standards. The test standards are UL-1482 and UL-737 for 
the United States, and EN13240:2001 + A2:2004 for Europe. The Defiant is listed for burning wood only.  Do not burn 
other fuels.  The Defiant is not approved for use in manufactured (mobile) homes. 
We recommend that you hire a professional installer to install your stove, or to advise you on the installation should 
you attempt to install it yourself.
Please read this entire manual before you install and use your new stove. Failure to follow instructions may result in 
property damage, bodily injury, or even death.

Save These Instructions for Future Reference

Welcome

Congratulations on your choice of a Vermont Castings Defiant stove. With this purchase you have made a commit-
ment to make the hearth a place of warmth, beauty and comfort in your home. At CFM Corporation, we share that joy 
and appreciation for the hearth. We assure you that your cast-iron Vermont Castings stove has been made with the 
utmost care and will provide you with many years of service. 
As you become acquainted with your new stove, you will find that its appearance is matched by its functionality, due to 
cast iron’s unique ability to absorb and radiate heat.
Also, CFM Corporation products are among the cleanest-burning wood stoves and fireplaces available today. As an 
owner of a Vermont Castings stove, you make a strong statement for pollution-free energy. However, clean burning 
depends on both the manufacturer and the operator. Please read this manual carefully to understand how to properly 
operate and maintain your stove.
At CFM Corporation, we are equally committed to your satisfaction as a customer. That is why we maintain an ex-
clusive network of the finest dealers in the industry. Our dealers are chosen for their expertise and dedication to 
customer service. They are factory-trained and knowledgeable about every CFM Corporation product. Feel free to 
contact your Authorized Vermont Castings Dealer anytime you have  a particular question about your stove or its 
performance.
This manual contains valuable instructions on the installation and operation of your Vermont Castings Defiant. It also 
contains useful information on maintenance. Please read the manual thoroughly and keep it as a reference.
Sincerely,

All of  Us at CFM Corporation

Содержание Defiant 1610CE

Страница 1: ...LED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN D...

Страница 2: ...our home At CFM Corporation we share that joy and appreciation for the hearth We assure you that your cast iron Vermont Castings stove has been made with the utmost care and will provide you with many...

Страница 3: ...mon sense of heating with wood a home grown fuel with none of the political and economic entanglements of foreign oil Thirteen years later in 1988 Vermont Castings retired the De ant replacing it with...

Страница 4: ...l contol Secondary Air Fixed self regulating Ash handling system Removable ash pan Glass panels High temperature ceramic Fig 1 De ant NC dimensions Drawing Not to Scale D E F I A N T 822 mm 32 733 mm...

Страница 5: ...ding a chimney or house re Follow all instruc tions exactly and do not allow makeshift compro mises to endanger property and personal safety All local regulations including those referring to national...

Страница 6: ...himney s clean out door must seal tightly A loose or leaky clean out door can weaken chimney draft caus ing performance problems Prefabricated Chimneys These should be an internal diameter of 150 mm 6...

Страница 7: ...s Lift off the griddle and shield the stove s surface between the griddle opening and the front of the ue collar to protect the nish when you drill the front hole Fasten each joint between sections of...

Страница 8: ...ended through the breech to the inner face of the ue liner and cemented securely in place Additional pieces of connector are then attached with sheet metal screws Fireplace Installations The chimney c...

Страница 9: ...before you begin Also check with the chimney connector manufacturer for any speci c requirements Accessories are available for use as wall pass throughs If using one of these make sure it has been tes...

Страница 10: ...Both a stove and its chimney connector radiate heat in all directions when operating and nearby combustible materials can overheat dangerously if they are too close to the heat source A safe installa...

Страница 11: ...op Fig 11 A Minimum distance from stove to movable combus tible materials e g furniture drying clothes etc 1220 mm 48 ST486a Defiant EU Clearance Diagrams 10 06 A B ST486a Fig 11 Minimum clearances Co...

Страница 12: ...gh surfaces can cause the legs to loosen or even break Leg Bolt and Washer ST858 Fig 18 Attach the stove legs ST564 handle holder 12 13 00 Bottom Heat Shield Door Handle Holder Leg Bolt and Washer ST5...

Страница 13: ...black handles Secure the handle to the stub on the right side of the stove with an 8 32 x 2 slot head machine screw Fig 22 Assemble the Removable Insert Handle The ceramic removable insert handle open...

Страница 14: ...that will last longer with less heat move the lever toward the rear of the stove A Damper Directs Air Flow Within the Stove The damper handle on the left side of the stove oper ates the damper to dire...

Страница 15: ...re viewing and should be left permanently in place Since the andirons may slightly hinder refueling through the front doors most stove owners will prefer the convenience of top loading through the gr...

Страница 16: ...requires an outside air vent for appliances with power outputs above 5 kW Always refer to national and local codes to determine your speci c requirements The De ant NC is equipped to deliver outside a...

Страница 17: ...the procedure as often as necessary if the initial attempt is unsuccessful 4 If your De ant has been broken in previously us ing Steps 1 3 continue to build the re gradually Add larger wood with a dia...

Страница 18: ...procedure Open the damper Open the griddle or front doors and use a shovel or poker to stir excess ash through the ash slots in the grate down into the ash pan Close the griddle or doors and unlatch...

Страница 19: ...house This uses the house as insulation for the ue and allows some heat release into the home An indoor chimney won t lose its heat to the outdoors so it takes less heat from the stove to heat it up a...

Страница 20: ...o dry and too vola tile Smoke and combustible gases can gas out from the wood quickly and densely enough to overload the combus tion system If you hear a rumbling or roaring noise like a propane torch...

Страница 21: ...lass with water or a cleaner made espe cially for this purpose Do not use abrasive cleaners Use cleaning agents sparingly and be sure to keep them off the outer surfaces of the stove Rinse the glass t...

Страница 22: ...ts until the setting is right Replace the Stove Gaskets as Needed Your De ant uses berglass rope gaskets to make a tight seal between some parts With use particu larly on moving parts gaskets can beco...

Страница 23: ...ali ed service technician 5 16 diameter gasket seals the following parts The lower reback to the back panel The left and right air plates inner sides All connections between the stove plates The Chimn...

Страница 24: ...lean the dust from the inner sides of bottom rear or pipe heat shields if your stove is equipped with them Clean surfaces are better heat re ectors than dirty surfaces Touch up the black paint Inspect...

Страница 25: ...71 73 80 78 68 33 2850 Defiant N parts 11 05 66 62 37 62 11 28 62 59 45 23 45 23 56 46 45 61 60 47 4 1 63 84 36 88 50 92 27 85 91 52 51 26 49 56 83 82 81 91 52 72 74 70 70 29 30 31 79 1 10 9 44 44 57...

Страница 26: ...0002810 54 Ashdoor Handle Wood 1600663 55 Ashdoor Hinge Rod 30002826 56 Cotter Pin Ashdoor 30001749 57 Ashdoor Bottom Hinge Support 1300642 58 Ashpan Bracket 30001908 59 Primary Air Flap 30002849 60 P...

Страница 27: ...0002891 30002881 30002934 Flue Collar 30001576 30002947 30002921 30002932 30002910 30001617 30002943 Front 30002830 30002873 30002914 30002925 30002893 30002883 30002936 Ashlip 30002811 30002870 30002...

Страница 28: ...n the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to the unit while in transit is not covered by this warranty but...

Отзывы: