Vermont Castings • Apsen C3 Installation Manual_R2 • 2019 - ___ • 07/19
5
8390-950i
A. Design & Installation Considerations
Consideration must be given to:
• Safety
• Convenience
• Traffic flow
• Chimney and chimney connector required
It is a good idea to plan your installation on paper, using exact
measurements for clearances and floor protection, before
actually beginning the installation. If you are not using an
existing chimney, place the appliance where there will be a
clear passage for a factory-built listed chimney through the
ceiling and roof.
We recommend that a qualified building inspector and your
insurance company representative review your plans before
and after installation.
If this appliance is in an area where children may be near
it is recommended that you purchase a decorative barrier
to go in front of the appliance.
Remember to always keep
children away while it is operating and do not let anyone
operate this appliance unless they are familiar with these
operating instructions.
C. Negative Pressure
Negative pressure results from the imbalance of air available
for the appliance to operate properly. It can be strongest in
lower levels of the house.
Causes include:
• Exhaust fans (kitchen, bath, etc.)
• Range hoods
• Combustion air requirements for furnaces, water
appliances and other combustion appliances
• Clothes dryers
• Location of return-air vents to furnace or air conditioning
• Imbalances of the HVAC air handling system
• Upper level air leaks such as:
- Recessed lighting
- Attic hatch
- Duct leaks
B. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
1. Install at least one smoke detector on each floor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’s placement and installation instructions,
and be sure to maintain regularly.
2
Getting Started
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building, fire officials
or authorities having jurisdiction about restrictions,
installation inspection, and permits.
CAUTION
!
Asphyxiation Risk
• DO NOT CONNECT THIS APPLIANCE TO
A CHIMNEY FLUE SERVICING ANOTHER
APPLIANCE.
WARNING
!
• DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
May allow flue gases to enter the house.
2. A conveniently located Class A fire extinguisher to contend
with small fires resulting from burning embers.
3. A CO detector should be installed in the room with the
appliance.
4. A practiced evacuation plan, consisting of at least two
escape routes.
5. A plan to deal with a chimney fire as follows:
In the event of a chimney fire:
a. Evacuate the house immediately
b. Notify fire department.
Notice:
Hearth & Home Technologies assumes no
responsibility for the improper performance of the
appliance system caused by:
•
Inadequate draft due to environmental conditions
• Down drafts
• Tight sealing construction of the structure
• Mechanical exhausting devices
• Over drafting caused by excessive chimney heights
• Ideal performance is with a chimney height of 16 Feet
(4.88m) measured from the base of the appliance.
Asphyxiation Risk
• Negative pressure can cause spillage
of combustion fumes, soot and carbon
monoxide.
• Appliance needs to draft properly for safety.
WARNING
!