8
Encore
®
2040CE Non-Catalytic / Catalytic Wood Burning Stove
30005552
* Check These
Clearances
Through the Fireplace
If your fi replace opening height is at least 737 mm (29"), you
may install an Encore through the opening using a “positive
connection” kit, available from your local dealer. These posi-
tive connection kits ensure a tight fi t between the stove fl ue
collar and the chimney fl ue. (Fig. 8)
Fireplace installations, whether connected to the fl ue above
or through the fi replace opening, have special clearance
requirements to adjacent trim and the mantel. You’ll fi nd the
required safe clearances for Encore fi replace installations
on Page 11.
Floor protection requirements also apply to fi replace instal-
lations. This information is on Page 9.
Wall Pass-Throughs
Whenever possible, design your installation so the connec-
tor does not pass through a combustible wall. If you are
considering a wall pass-through in your installation, check
with your building inspector before you begin. Also, check
with the chimney connector manufacturer for any specifi c
requirements.
Accessories are available for use as wall pass-throughs.
If using one of these, make sure it has been tested and
listed for use as a wall pass-through.
Flexible Connector
Mantel Shield
Fireplace Adapter
Kit “Positive Con-
nection”
ST245
Fig. 8
In this installation, the chimney connector enters the
fi repalce opening and then connects to the chimney.
Figure 9 shows one method of passing a connector through
a wall. All combustible material in the wall is cut away to
provide the required 457 mm (18”) clearance for the con-
nector. The resulting space must remain empty. A fl ush-
mounted sheet metal cover may be used on one side only.
If covers must be used on both sides, each cover must be
mounted on noncombustible spacers at least 25 mm (1”)
clear of the wall.
Your local dealer or your local building inspector can provide
details for other approved methods of passing a chimney
connector through a combustible wall in your area.
T
457 mm (18”) clear
space all around the
pipe
ST494
Fig. 9
An approved wall pass-through.
DO NOT CONNECT AN ENCORE TO ANY AIR DIS-
TRIBUTION DUCT OR SYSTEM.
D E F I A N T
*
*
Check These
Clearances
Mantel
ST244a
Fig. 7
In this installation, the chimney connector attaches to
the chimney above the fi replace opening.
Seal
This Off