BC1000XL Brush Chipper Maintenance
1000 Service Hours 50-3
C
OOLING
S
YSTEM
- D
RAIN
AND
C
LEAN
Step 1:
Drain old coolant from cooling system.
Step 2:
Fill radiator with clean water. Check for signs of rust and add a cooling system cleaner to the water if
necessary.
Step 3:
Follow
Starting Procedure
in the
Operator’s Manual
. Run engine long enough to be sure the thermostat
has opened, allowing the engine and radiator to receive fresh water.
Step 4:
Follow
Shutdown Procedure, page 15-1.
Allow system to cool, then drain the water.
Step 5:
Add a 50/50 mixture of low-silicate (ethylene glycol) antifreeze and clean water to the radiator. Do not
fill completely. Follow
Starting Procedure
and run engine until mixture has circulated in the system.
Step 6:
Fill radiator. System capacity is approximately 14 qt (13 L).
Recheck radiator after engine has cooled overnight. Fill as necessary. Continue to check each time machine is
run and cooled off until radiator remains full.
WARNING: Hot fluid under pressure can scald.
Allow engine to cool before opening radiator cap.
Содержание BC1000XL
Страница 1: ...BC1000XL Brush Chipper BC1000XL_m3_06 Serial No 5001 Order No 105400V87 Maintenance Manual ...
Страница 4: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 12: ...This page intentionally left blank ...
Страница 38: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 76: ...This page intentionally left blank ...
Страница 94: ...This page intentionally left blank ...
Страница 98: ...This page intentionally left blank ...