![Vermeer BC1000XL Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/vermeer/bc1000xl/bc1000xl_maintenance-manual_1005417058.webp)
40-6 250 Service Hours
BC1000XL Brush Chipper Maintenance
A
IR
C
LEANER
- R
EPLACE
When the air cleaner restriction indicator (1) is checked (refer to the
section, “Air Cleaner Restriction Indicator - Check,”
) and indicates that service
is required, the air cleaner element must be replaced.
To replace element:
Step 1:
Release three clamps (2).
Step 2:
Remove cover (3) and dirty primary element (4).
Step 3:
Check secondary element (5); replace every 1000 service hours, sooner if dirty
or damaged.
NOTE:
The secondary element that fits inside the primary filter element is provided for
additional protection during field changes and should not be removed except in a clean
environment.
Step 4:
Check replacement air cleaner element for damage.
Step 5:
Install air cleaner element. Ensure end of the element with a gasket is installed
against closed end of air cleaner assembly, and is seated properly.
Step 6:
Install cover; ensure all fasteners and/or clamps are tight.
4
5
2
3
1
3_04
Содержание BC1000XL
Страница 1: ...BC1000XL Brush Chipper BC1000XL_m3_06 Serial No 5001 Order No 105400V87 Maintenance Manual ...
Страница 4: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 12: ...This page intentionally left blank ...
Страница 38: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 76: ...This page intentionally left blank ...
Страница 94: ...This page intentionally left blank ...
Страница 98: ...This page intentionally left blank ...