Description

A digital instrument with a
programmable IC at its heart that will
test the resistance of an operator's
grounding system(s) mounted on a
black metal frame with a black
wooden base board. The 222522 will
test the operator's ESD footwear.
The 222523 will additionally test the
operator's wrist strap. The stations
test both feet simultaneously. The
instrument will indicate whether the
resistance is in the ranges specified
in EN 61340-5 and ANSI/ESD S1.1 &
S20.20.

“Wrist straps shall be checked before
use.  Each check shall be made with
the wrist band worn in contact with
the wearer's skin and with the ground
cord attached to the appropriate
tester.” (EN 61340 5 1 paragraph 9.6
Daily checks, paragraph 9.6.2 Wrist
strap)  “Where toe and heel straps
are used as ESID footwear, once
these are worn outside the EPA [ESD
protected area], particularly on
carpets, they are likely to accumulate
fluff and become ineffective; this

requires that they be checked or
replaced on every visit to the EPA.
…When ESD footwear is used, it
should be noted that ESD footwear
alone cannot achieve protection, but
needs to be used in conjunction with
a suitable ESID floor.” (EN 61340-5-2
Paragraph 5.2.8 Footwear)   “All
wearers shall check that their heel
and toe straps meet requirements [of
Table 1 NOTE 2 – ‘When the
footwear/floor systems are used as
the primary means of grounding
personnel, the resistance of the
combination shall be determined by
the ESD co-ordinator, and is
recommended to be between 7,5 x
10E5 ohms1 and 3,5 x 10E7 ohms’].
The check shall be made before
entering the EPA.” (EN 61340 5-1
Daily checks, paragraph 9.6.3 Non-
permanent footwear)

Inspection

Remove the test unit from the carton
and inspect for shipping damages.  

Each 222522 unit should include the
following:

1 Test unit, item #222522
1 Test Stand Assembly

Each 222523 unit should include the
following:

1 Test unit, item #222523
1 Test Stand Assembly

Installation

1. Remove the components from the 

packaging.

2. Lay out the baseboard and upright 

bar using the packaging to protect 
the paintwork.

3. Stand the baseboard on the rear 

edge and offer the upright to 
connect the 2 leads and align the 
4 bolt holes. 

4. With the leads connected, feed the 

surplus cord back into the upright, 
and then fit the four bolts from the 
top. The washers and nuts can 
then be fitted and tightened.

5. Stand the test stand up. 
6. Insert the tester plugs through the 

two larger holes in the instruction 
panel. The connectors on the back 
of the tester fit into the sockets on 
the upright.

7. Place both in position, using the 

two M5 bolts to secure the tester 
& panel to the upright.

8. Perform a check on each plate 

individually to check the 
connections. If practical, remove a 
shoe and stand in stockinged feet 
on one footplate. Perform a test - 
you should obtain a pass or fail 
low. (Most likely fail low). Repeat 
the test with the foot on the other 
test plate.

9. The test station is now ready for 

use.

Procedure to test footwear

1. Wear ESD shoes or heel 

grounders as prescribed.

2. Stand on the footplates.
3. Press the round metal button on 

the tester with one or two fingers.  
The tester will now indicate    
whether the total resistance is 
within the acceptable range. 

4. Green light and buzzer indicate 

that the total resistance is either 
less than 10M

or less than 

35M

.

Green = OK

You may now enter the EPA.

5. A red light indicates non-

conformance. 

Red = FAIL

Do not proceed in the usual 
manner but contact your 
supervisor or follow your company 
procedure.

6. Contact your supervisor if the 

battery low light comes on.

Procedure to test wrist strap

1. Wear wristband. Choose one that 

fits snugly or adjust it to do so.

2. Connect the ground cord securely 

to the band using the snap 
connector.

3. Connect the other end of the cord 

to a matching termination on the 
tester.