Verland Titan T3000 Скачать руководство пользователя страница 1

OverlandTandberg.com

INSTALLATION GUIDE

Titan T3000

Installation and 

Storage Expansion Guide

© Dell Technologies

Содержание Titan T3000

Страница 1: ...OverlandTandberg com INSTALLATION GUIDE Titan T3000 Installation and Storage Expansion Guide Dell Technologies...

Страница 2: ...Dell EMC PowerProtect DD6400 System Installation and Storage Expansion Guide February 2022 Rev 04...

Страница 3: ...ial damage to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death 2021 2022 Dell Inc or its subsidiarie...

Страница 4: ...move filler panels 19 Install an ES40 shelf into the rack 19 Installing the rails in the cabinet 19 Installing the shelf on the rails 22 Installing and locking the front bezel 23 Chapter 4 Connect Cab...

Страница 5: ...lent 40 Chapter 6 Installation Troubleshooting 41 Installation troubleshooting scenarios 41 Appendix A Add Storage Capacity 43 Prepare system for storage expansion 43 Install and connect the new stora...

Страница 6: ...m into the extended rails 16 12 Slide system into the rack 16 13 Installing the front bezel 17 14 Install the seperator 17 15 Install the arm 18 16 Close the arm 18 17 Holes for alignment pins 21 18 I...

Страница 7: ...00 to ES40s cabling instructions 26 4 DD6400 with two ES40s ES40 to ES40 cabling instructions 27 5 I O Module Slot assignments 28 6 Maximum FC cable lengths 28 7 iDRAC NIC to physical port mapping 33...

Страница 8: ...m the DD OS 7 7 Drivers Downloads section on the Data Domain Product Support page https www dell com support home en us product support product dd os 7 7 drivers For complete instructions on updating...

Страница 9: ...ystem Review the following table before installing the DD6400 Requirement Description Rack space DD6400 controller only 2U DD6400 controller with one ES40 5U DD6400 controller with two ES40s 8U Rack p...

Страница 10: ...E SFP 3 maximum 4 port 10GBASE T 3 maximum 4 port 16 Gb FC 1 maximum Network Daughter Card option system will have one of the two options 4 port 10 GbE SFP 1 4 port 10GBASE T 1 Product serial number t...

Страница 11: ...ntistatic wrist strap and conductive foam pad Screwdrivers Phillips 1 Phillips 2 with a 4 to 6 inch blade and a magnetic tip Phillips 2 with a 12 in or longer blade and magnetic tip Flat head with a 3...

Страница 12: ...ould not be removed unless a replacement can be added immediately Do not run the system without all parts in place Provide a suitable power source with electrical overload protection Provide a safe el...

Страница 13: ...m in the cabinet Install the front bezel Install the CMA arm Identifying the rail kit components The 2U sliding rail assemblies allow the server to be secured in the cabinet and extended from the cabi...

Страница 14: ...t NOTE Install the left rail assembly first 2 Fully extend the rear sliding bracket of the rail 3 Position the rail end piece labeled Left Front facing inward and orient the rear end piece to align wi...

Страница 15: ...hole cabinets install the supplied conical washer before installing the screw For unthreaded round hole cabinets install only the screw without the conical washer Steps 1 Align the screws with the de...

Страница 16: ...teps 1 Pull the inner rails out of the rack until they lock into place 2 Release the inner rail lock by pulling forward on the white tabs and sliding the inner rail out of the intermediate rails Figur...

Страница 17: ...ase lock tabs forward on both the rails and slide the system into the rack Figure 12 Slide system into the rack Install the front bezel The procedure to install the front bezel with the LCD panel and...

Страница 18: ...ezel Install the CMA arm Steps 1 Install the separator on the bracket Figure 14 Install the seperator 2 Install the arm on the right side of the chassis on top of the separator with the open side up I...

Страница 19: ...Figure 15 Install the arm 3 Close the arm by connecting it to the bracket on the left side of the chassis Figure 16 Close the arm 18 Install the System in the Rack...

Страница 20: ...ps in this section to install the rails ES40 expansion shelf and bezel Follow these steps for each ES40 shelf you are installing There are no specific placement requirements for the ES40 shelves in re...

Страница 21: ...Steps 1 From the front of the cabinet insert the rail alignment pins above and below the bottom U mark on the rear cabinet channel 20 Install the Disk Shelves in the Rack...

Страница 22: ...Alignment pins here EMC2892b 3U Rear channels Figure 17 Holes for alignment pins Install the Disk Shelves in the Rack 21...

Страница 23: ...he rails About this task CAUTION The system components are heavy To avoid personal injury and or damage to the equipment do not attempt to install or remove system components without a mechanical lift...

Страница 24: ...el before you install the bezel Failure to remove this strip will cause the system to overheat About this task NOTE If the rack is equipped with a door on the front the shelf ships with an EMI shield...

Страница 25: ...CL5674 Figure 21 Installing the front bezel 24 Install the Disk Shelves in the Rack...

Страница 26: ...s and Power On Topics Connecting ES40 shelves DD6400 with ES40 cabling Connecting data cables Connecting disk shelf power cables Connecting controller power cables and powering on 4 Connect Cables and...

Страница 27: ...th ES40 cabling The DD6400 system supports a maximum of two ES40 shelves The diagrams show a single shelf and two shelves cabled in a single loop Table 2 DD6400 with one ES40 cabling instructions Stri...

Страница 28: ...onger cables up to 5M can be used Figure 23 DD6400 with two ES40 shelves Connecting data cables About this task Slot numbers The following figure shows the I O module slot numbers The slot labeled N i...

Страница 29: ...eight 4 Broadcom LSI 9300 8e 2 x 12 Gbps SAS PCIe Low Profile internal SAS 6 Steps 1 For 10 GBASE T connections use one of the following Unshielded Cat 6 cables with RJ 45 connectors that do not excee...

Страница 30: ...wering on the controller Steps 1 Connect the power supply units to the rack CAUTION Connect each PSU to a redundant AC power source Redundant power sources allow one AC source to fail or be serviced w...

Страница 31: ...IOS settings as making changes will impact system functionality Contact Support if changes are required in any of these areas The system uses the following key mapping for console redirection Use the...

Страница 32: ...re 26 iDRAC Settings Network 7 Press Esc to return to the previous menu 8 Select User Configuration a Enable the root user b Change the root user password NOTE The default password is the system seria...

Страница 33: ...ser type the iDRAC IP address specified during iDRAC configuration 2 Login with the user name root The default password is the system serial number on the PSNT 3 Select Configuration BIOS Settings Ser...

Страница 34: ...1 1 1 Network daughter card port 1 LOM2 NIC Integrated 1 2 1 Network daughter card port 2 LOM3 NIC Integrated 1 3 1 Network daughter card port 3 LOM4 NIC Integrated 1 4 1 Network daughter card port 4...

Страница 35: ...onsole 1 Log in to the system console using the sysadmin username localhost localdomain login sysadmin 2 Type the default password which is the system serial number The system serial number is a 14 ch...

Страница 36: ...icts with the DDOS iDRAC interconnect do not configure 169 254 0 X and 169 254 1 X IP addresses Steps 1 Enter yes to configure the system for network connectivity Network Configuration Configure Netwo...

Страница 37: ...one two or three IP addresses 192 168 10 1 9 A summary of the network settings is displayed You can accept the settings Save reject the settings and exit to the CLI Cancel or return to the beginning o...

Страница 38: ...Lab 5000 Apple Drive Suite 130 Dallas Tx 3 To add one or more time servers enter ntp add timeserver 192 168 101 1 Remote Time Servers 192 168 10 1 4 To enable the NTP daemon enter ntp enable NTP enabl...

Страница 39: ...dialog box to select which features to configure and to advance through the wizard To display help for a feature click the help icon question mark in the lower left corner of the dialog box License Th...

Страница 40: ...irtual Edition VE Gateway provides automated connect home and remote support activities through an IP based solution that is enhanced by a comprehensive security system About this task An on site Secu...

Страница 41: ...ir as a user will fail and cause the RSA key token to become out of synch 3 To enable the sending of autosupports enter support notification enable all Enabled sending autosupport and alerts to EMC 4...

Страница 42: ...BA DDOS does not load Reinstall DDOS The DDOS USB Installation Guide provides instructions to reinstall DDOS from a USB image Incorrect version of DDOS installed Upgrade to the desired DDOS version CA...

Страница 43: ...FPs are fully seated and are known to be functional ES40 shelves not detected Verify the SAS HBA and all SAS cables are fully seated NVRAM not charged The NVRAM module takes 2 3 hours to reach 80 char...

Страница 44: ...before proceeding with the upgrade procedure Steps 1 Log in as a sysadmin user 2 Display the current alerts on the system Run the following command alerts show current alerts show current No active a...

Страница 45: ...enclosure All the new disks should display in the Unknown state For a new ES40 disk show state Enclosure Disk 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 U U U U U U U U U U U U U U U Legend State C...

Страница 46: ...ectronic license file txt Run the command without parameters to run the command interactively elicense update Enter the content of license file and then press Control D or press Control C to cancel Ex...

Страница 47: ...tal 42 disks For a new ES40 disk show state Enclosure Disk 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 Legend State Count In Use Disks 42 Total 42 disks 4 Display the current alerts on the system Run...