Verine NRDC**MN2 Скачать руководство пользователя страница 1

Important Note

This manual is only suitable for Verine Quasar MK2 models that are to be installed in

GB / IE. If in the future the product is to be installed in any other country detailed as

appropriate for the gas type and supply pressure on the rating plate then the

manufacturer (BFM Europe Ltd.) must be contacted to obtain a set of instructions that

are translated into the language of the country of destination, and reflect the differing

legislative installation criteria for that country.

Quasar MK2

INSET RADIANT FUEL EFFECT GAS FIRE

Installation, Maintenance & User Instructions
Hand these instructions to the user

Model No’s NRDC**MN2, NRDC**SN2, NRDC**TN2 & NRDC**RN2 are

for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B.

/ I.E.

Model No’s NRDC**MP2 is for use on Propane Gas (G31) at a supply

pressure of 37 mbar in G.B. / I.E.

** denotes variant of trim / fascia where applicable

Содержание NRDC**MN2

Страница 1: ...tions that are translated into the language of the country of destination and reflect the differing legislative installation criteria for that country Quasar MK2 INSET RADIANT FUEL EFFECT GAS FIRE Ins...

Страница 2: ...l models 30 31 3 9 Lighting the appliance Remote control models 32 3 10 Lighting the appliance Electronic fire control models 33 3 11 Checking for clearance of combustion products 34 Section 4 Mainten...

Страница 3: ...ut fender Slide Control Models 13 kg Manual Control Models 12 kg Remote EFC Models 13 5 kg Fire box Dimensions with trim s fitted Width with standard trim no spacer 470mm Height with standard trim no...

Страница 4: ...1858 Clay Flue Blocks and Terminals 7 IS 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B Whe...

Страница 5: ...150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that the chimney flue only ser...

Страница 6: ...ied out during commissioning of the appliance 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 375 and 440 mm wide and between 550 and 570mm high...

Страница 7: ...of the chairbrick providing the minimum depth of the fireplace exceeds 260mm If the depth is less than 260mm then the spacer optional must be used to give a minimum clearance from the rear of the fire...

Страница 8: ...ill be insufficient depth If in doubt about the suitability of the fire contact BFM Europe Ltd for advice before proceeding This fire has been designed to fit standard 100mm pre cast starter blocks wi...

Страница 9: ...h the fire is operated The following are important warnings relating to this spillage monitoring system 1 The spillage monitoring system must not be adjusted by the installer 2 The spillage monitoring...

Страница 10: ...off AA Batteries 2 2 INSTALLING THE FIRE BOX Establish which type of flue you are intending to install the fire in to 225 x 225mm 9 inch x 9 inch brick built chimneys 175mm 7 inch diameter lined bric...

Страница 11: ...ted from damage and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with n...

Страница 12: ...ps present f Remove the burner To allow burner removal the control lever operat ing cable must be removed The control lever operating cable can be seen running across the base of the fire below the bu...

Страница 13: ...g screws at either side of the firebox and the two fixing screws at the base of the fire See fig 7 below Carefully pull the base of the burner forwards from the fuel bed support panel The burner can n...

Страница 14: ...ully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps present c Remove t...

Страница 15: ...to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 10 11 below for suggested concealed pipe layouts Fig 10...

Страница 16: ...which in turn will damage the burner and control systems of the product Fig 12 below shows a correctly sealed installation Fig 12 PLEASE NOTE Seal off unused gas inlet apertures and cable fixing hole...

Страница 17: ...f the clearance at the rear of the fire is at the minimum specified for a precast flue application it may be necessary to bend over the lower fixing eyes after screwing them fully in to the rear of a...

Страница 18: ...ull the seal up against the sealing face of the wall it does not need to be compressed Check that there are no gaps behind the seal n With the fire securely in place if a concealed gas connection has...

Страница 19: ...2 Screws and secure the trim to the fire using the magnets provided q Before making the final gas connection thoroughly purge the gas supply pipework to remove all foreign matter otherwise serious da...

Страница 20: ...c Depress the control lever to the position marked pilot Hold down the control lever for a few seconds to purge the pipe work The burner should light continue to hold the control lever for a few secon...

Страница 21: ...support and is not lodged on the burner See fig 16 below Fig 16 b Position the two halves of the front ceramic L H R H on the locating channel in the front ceramic ensuring it is located onto the lip...

Страница 22: ...mic rail as a guide for placement See fig 18 below Fig 18 d Select two of the large square coals two of the large random coals and arrange behind the front row of coals ensuring that flame paths as in...

Страница 23: ...ong the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 20 below Fig 20 f Select the two small coals and position to fill the gaps at each end of the thi...

Страница 24: ...ic Fibre articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after wo...

Страница 25: ...urner See fig 23 below Fig 23 b Position front ceramic rail on burner front ceramic support and ensure that the locating channel in the front ceramic rail is correctly located onto the lip on the burn...

Страница 26: ...n the front ceramic rail as a guide for placement See fig 25 below Fig 25 d Select pebbles F to I and arrange behind the front row of pebbles ensuring that flame paths as indicated below are not inter...

Страница 27: ...ensure that the release of fibres from these R C F Refractory Ceramic Fibre articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove...

Страница 28: ...self adhesive pad and infrared eye attached to the flying lead as supplied from the factory Fig 28 b Remove the backing paper from the self adhesive pad and position the infrared eye in the air chann...

Страница 29: ...port cradle at the bottom R H side of the firebox burner assembly c The wire and connecting plug from the battery pack should then be connected into the supply wire running from the control board See...

Страница 30: ...control knob and turn to the off position the pilot will now be extinguished 3 8 LIGHTING THE APPLIANCE SLIDE CONTROL MODELS a Turn on the isolation valve Depress the control lever fully downwards to...

Страница 31: ...d heat output e To turn the fire off FULLY raise the control lever to the OFF position WARNING If the fire goes out for any reason or is turned off and it isnecessary to re light the fire it is import...

Страница 32: ...an audible clicking can be heard and then the fire will light the pilot and then light the main burner The ignition cycle will take approximately 20 seconds c To reduce the level of heat input on the...

Страница 33: ...lame button on the trim switch An audible beep will be heard c To increase the level of heat input on the fire press the large flame button on the trim switch An audible beep will be heard d To leave...

Страница 34: ...cooled d If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified the fire must be disconnected from the gas supply...

Страница 35: ...m in a safe location Remove the loose coals pebbles from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which secure the burner heat...

Страница 36: ...ot it is not possible to replace the thermocouple separately because the thermocouple position is factory set to a tight tolerance Any replacement of parts on the pilot requires a complete new pilot a...

Страница 37: ...ushing the bottom of the burner back into position Secure using the two screws into the side frame of the firebox and two screws into the base It is now necessary to refit and correctly tension the op...

Страница 38: ...he microswitch 4 8 3 Unscrew and remove the two pozi drive screws which secure the pilot assembly to the burner Remove the pilot 4 8 4 Re assemble in reverse order and carry out a gas tightness test 4...

Страница 39: ...ush in the gap between the two lengths of p t f e sleeve Ensure that the cable is located in the retaining hole in the locking bush and tighten the screw sufficiently to retain the cable but still all...

Страница 40: ...wiring is fitted correctly to the PCB assembly Push the base of the control panel fully into the fire and secure with the four screws Refit the gas supply pipe and carry out a gas tightness test Refit...

Страница 41: ...carried out by a competent person such as a GAS SAFE registered gas installer The part numbers of the replaceable parts are as follows these are available from BFM Europe Ltd whose contact details may...

Страница 42: ...nsult document I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is fr...

Страница 43: ...ppliance is serviced at least once a year by a GAS SAFE registered installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen d...

Страница 44: ...be lit as follows Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to allow the gas to reach the pilot Insert the tip of a lit t...

Страница 45: ...n the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if necessary replace with a AA size alkaline battery It is impor tant that only an alkaline battery...

Страница 46: ...ire and press the small flame button once An audible beep will be heard and the heat input level will reduce to the low setting 4 2kW Press and continually hold the small flame button and the fire wil...

Страница 47: ...flame button on the trim switch An audible beep will be heard c To increase the level of heat input on the fire press the large flame button on the trim switch An audible beep will be heard d To leav...

Страница 48: ...plete see Fig 3 below d When the fire has shut down release the emergency shut off switch e The appliance will now remain in the off position until activated by the remote handset EFC trim switch whic...

Страница 49: ...the fire has been allowed to fully cool CLEANING THE TRIMS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen to clea...

Страница 50: ...fuelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 4 below Fig 4 b Position the two halves...

Страница 51: ...ramic rail as a guide for placement See fig 6 below Fig 6 d Select two of the large square coals two of the large random coals and arrange behind the front row of coals ensuring that flame paths as in...

Страница 52: ...along the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 8 below Fig 8 f Select the two small coals and position to fill the gaps at each end of the thi...

Страница 53: ...kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the applianc...

Страница 54: ...base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 11 below Fig 11 b Position front ceramic rail on...

Страница 55: ...n the front ceramic rail as a guide for placement See fig 13 below Fig 13 d Select pebbles F to I and arrange behind the front row of pebbles ensuring that flame paths as indicated below are not inter...

Страница 56: ...sure that the release of fibres from these R C F Refractory Ceramic Fibre articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any...

Страница 57: ...ose contact details may be found below Pebble fuelbed base B 77260 Pebble fuelbed front rail B 58140 Replacement pebble set B 77250 Coal fuelbed base B 56320 Coal fuelbed front rail B 56330 Replacemen...

Отзывы: