Air Line
Models that Include a Compressor:
An air line is already connected from the compressor
to the pump air inlet.
Using Your Own Compressor:
Install a grounded, flexible air hose from the
compressor to the pump air inlet (E).
Using Shop Air:
1. Install an air filter/regulator assembly (H). The
fluid stall pressure will be the same as the setting
ofthe air regulator. The filter removes harmful
dirt and moisture from the compressed air supply.
2. Locate a bleed-type master air valve (G) close to
the pump and use it to relieve trapped air. Be
sure the valve is easily accessible from the pump
and located downstream from the regulator.
Trapped air can cause the pump to cycle
unexpectedly, which could result in serious
injury from splashing.
3. Locate another master air valve (J) upstream
from all air line accessories and use it to isolate
them during cleaning and repair.
4. Install a grounded, flexible air hose (F) between
the accessories and the pump air inlet.
Fluid Supply Line
1. Connect a grounded, flexible fluid hose (K) to
the fluid inlet port. The port on pumps with
aluminum, stainless steel, or cast iron fluid
sections is 2 in npt(f) or 2 in. bspt. On pumps
with polypropylene, conductive polypropylene,
or PVDF fluid sections, the port is a 2 in. raised
face ANSI/DIN flange.
2. Ifthe inlet fluid pressure to the pump is more
than 25% ofthe outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation. Excessive inlet
fluid pressure also will shorten diaphragm life.
Approximately 0.21–0.34 bar (0.02–0.03 MPa,
3–5 psi) should be adequate for most materials.
3. For maximum suction lift (wet and dry), see
. For best results, always
install the pump as close as possible to the
material source. Minimize suction requirements
to maximize pump performance.
Fluid Outlet Line
1. Connect a grounded, flexible fluid hose (N) to
the fluid inlet port. The port on pumps with
aluminum, stainless steel, or cast iron fluid
sections is 2 in npt(f) or 2 in. bspt. On pumps
with polypropylene, conductive polypropylene,
or PVDF fluid sections, the port is a 2 in. raised
face ANSI/DIN flange.
2. Install a fluid drain valve (L) near the fluid outlet.
3. Install a shutoff valve (M) in the fluid outlet line.
14
859.0761
Содержание VERDERAIR VA-E50
Страница 27: ...Dimensions Dimensions Aluminum or cast iron pump with compressor 859 0761 27 ...
Страница 28: ...Dimensions Aluminum or cast iron pump without compressor 28 859 0761 ...
Страница 31: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump with compressor 859 0761 31 ...
Страница 32: ...Dimensions Polypropylene Conductive Polypropylene or PVDF pump without compressor 32 859 0761 ...
Страница 34: ...Dimensions Stainless steel pump with compressor 34 859 0761 ...
Страница 35: ...Dimensions Stainless steel pump without compressor 859 0761 35 ...
Страница 37: ...Notes Notes 859 0761 37 ...