Operation
Pressure Relief Procedure
Follow the Pressure Relief Procedure when-
ever you see this symbol.
1. Close the master air valve (A) to shut off the air to
the pump.
2. Open outbound fluid valve to relieve fluid pressure
from the pump.
a.
For simple transfer applications,
open either
the fluid shutoff valve (J) or the fluid drain valve
(K).
b.
For circulating applications,
ensure that the
fluid shutoff valve (J) is closed and open the
fluid drain valve (K).
Sanitize the Pump Before First
Use
NOTE:
The pump was built and tested using a food
grade lubricant.
Properly sanitize the pump before first use. The user
must determine whether to disassemble and clean
individual parts or simply flush the pump with a
sanitizing solution.
To simply flush the pump with a sanitizing solution,
follow the steps under
page 13, and
disassemble and clean individual parts, refer to the
appropriate Repair manual.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as splashing fluid, follow the
Pressure Relief Procedure when you stop dispensing
and before cleaning, checking, or servicing the
equipment.