Internal Element Cover/Air Guide:
Attention to either the fan or the heaters is achieved by opening the air guide.
The air guide is a one piece unit which is released without removal of any screws. Open
the door and remove the shelves and the right hand side shelf runners. The air guide is
hinged and swings open to reveal the fans and heaters after removal of the retaining
pins.
6.4
Temperature Controller Replacement
Refer to the controller instructions for more information on how to replace the
temperature controller.
6.5
Fuse Replacement
Fuses are accessed by removal of the appropriate panel, as described in the 'Panel
Removal' section. Depending on the model, supply fuses and control circuit fuses may
be mounted in their own holders, or may be on a circuit board that contains an EMC
filter. The fuses are marked with their ratings.
Take care not to disconnect the wires leading from the EMC filter without first recording
their positions: they must be reconnected to the correct terminals.
6.6
Element Replacement
See section 6.3 for details on how to gain access.
l
Disconnect the wires from the heating element terminals.
l
Remove any starlock washers - these may need to be cut with wire cutters.
l
Remove any clips holding the element inside the chamber and withdraw the ele-
ment.
l
Reverse the procedure when fitting the new heating element.
l
To find out whether the heating element failure was caused by a fault in the control
circuit, operate the product at a low temperature and check that it is functioning cor-
rectly.
Compression fittings are only fitted to moisture extraction and stoving and curing
products. If fitted, ferrules need replacing.
Old elements may be to be cut to remove from the oven.