Vents TwinFresh Expert RW1-50S3-13 Скачать руководство пользователя страница 1

TwinFresh Expert RW1-50S3-13 V.2

Single-room reversible energy recovery ventilator

USER’S MANUAL

Содержание TwinFresh Expert RW1-50S3-13

Страница 1: ...TwinFreshExpertRW1 50S3 13V 2 Single room reversible energy recovery ventilator USER S MANUAL...

Страница 2: ...5 Unit design and operating principle 6 Installation and set up 8 Connection to power mains and control 11 Technical maintenance 24 Storage and transportation regulations 26 Manufacturer s warranty 2...

Страница 3: ...electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or hig...

Страница 4: ...xplosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances...

Страница 5: ...inimum Wall thickness is minimal Outer ventilation hood Front panel Front panel Cartridge Cartridge Air duct length Wall thickness Outer ventilation hood A protruding part of the air duct on the outer...

Страница 6: ...ation VENTILATOR DESIGN The ventilator consists of an indoor unit with a decorative front panel a cartridge an air duct with a sound absorbing layer and an outer ventilation hood The cartridge is a ba...

Страница 7: ...om the room and flows through the ceramic regenerator which gradually absorbs heat and humidity In 70 seconds as the ceramic regenerator gets warmed the ventilator is switched to air supply mode Cycle...

Страница 8: ...duct in the wall For ease of installation use the foam wedges included in the delivery set The air duct end must protrude for the distance A that enables installation of an outer ventilation hood Dist...

Страница 9: ...h and detach the front part of the indoor unit from its back part ATTENTION Prior to mounting the front panel make sure that the thermal actuator rod is in the lowest position Blinking of the white LE...

Страница 10: ...stall the front part of the indoor unit 9 Insert the sound absorbing layer in the air duct Roll the layer of the sound absorbing material to match the air duct diameter The protecting paper layer must...

Страница 11: ...e terminal block installed in the control board in compliance with the wiring diagram and terminal designation Connect the ventilator to power mains through an automatic circuit breaker with magnetic...

Страница 12: ...ve unit hereinafter referred to as Slave unit Standby mode setup 2 OFF the ventilator is switched off in the Standby mode 2 ON the ventilator operates at Speed I in the Standby mode Setupofairflowdire...

Страница 13: ...unit in the air supply mode This mode may be activated only via the mobile application Filter 90 days after installation of the cartridge the filter replacement indicator starts glowing In this case c...

Страница 14: ...or operates in permanent air supply or air extraction mode at set speed The fan rotation direction depends on the position of the DIP switch 3 Timer control buttons Party mode the timer activates oper...

Страница 15: ...device to a Wi Fi access point FAN 16 characters of the ID number indicated on the control board of the ventilator Wi Fi access point password 11111111 1 2 4 5 6 8 7 3 Enter the Vents TwinFresh V 2 a...

Страница 16: ...DESCRIPTION OF MOBILE APPLICATION INDICATORS Current type of connection to the ventilator Home connection or connection via a cloud server through Internet respectively Speed III activation indicator...

Страница 17: ...return to the standard state To set up sensor operation via the mobile app go to Menu Settings Sensors Humidity sensor activation of the humidity sensor When the indoor humidity exceeds the set point...

Страница 18: ...ers is signalled by the indicator in the upper section of the Control menu Replace the filter and reset the filter timer To reset the filter timer via the mobile app go to Menu Settings Filter Then pr...

Страница 19: ...set on Master units To set up ventilator Wi Fi parameters via the mobile app go to Menu Connection WI FI setup Press the Receive button to display the current Wi Fi settings Select one of the Wi Fi op...

Страница 20: ...e mobile devices are connected to a wireless access point of the Wi Fi router In this case the Master unit can operate with the number N of Slave units limited by the technical characteristics of the...

Страница 21: ...nctions To enter the special Setup mode press and hold the Ventilation button on the ventilator casing for 5 seconds until the beep and blinking of all the LED lights The ventilator will continue in t...

Страница 22: ...spective button if necessary 5 Enter a ventilator name of choice the ventilator ID as stated on the control circuit board and the unit password 1111 by default 6 Confirm the updated details To log int...

Страница 23: ...unit functionality is not changed To open the air duct pull the front panel while holding the special recesses The fan starts operating according to the actual speed setting Air duct blocking Air duct...

Страница 24: ...e of the indoor control unit to take off the front part Please make sure the thermal actuator rod is in lower position during re installation of the front panel If the thermal actuator rod is up pleas...

Страница 25: ...ervice life is 3 years Some dust may accumulate on the heat exchanger block even in case of regular maintenance of the filters Clean the regenerator regularly to ensure its high heat recovery efficien...

Страница 26: ...r up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours POSSIBLE REASONS AND TROUBLESHOOTING Problem Possible reasons Troubleshooting Wh...

Страница 27: ...ler for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including s...

Страница 28: ...28 TwinFresh Expert RW1 50S3 13 V 2 www ventilation system com...

Страница 29: ...29 www ventilation system com...

Страница 30: ...30 TwinFresh Expert RW1 50S3 13 V 2 www ventilation system com...

Страница 31: ...tomer s Signature The TwinFresh Expert __________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Instal...

Страница 32: ...V133 6EN 01...

Отзывы: