Vents TwinFresh Expert RW-30 V.2 Скачать руководство пользователя страница 1

TwinFresh Expert RW-30 V.2

Single-room reversible energy regeneration ventilator

USER’S MANUAL

Содержание TwinFresh Expert RW-30 V.2

Страница 1: ...TwinFresh Expert RW 30 V 2 Single room reversible energy regeneration ventilator USER S MANUAL...

Страница 2: ...or by any means in any information search system or translated into any language in any form without the prior written permission of the Company All user s manual requirements as well as the provisio...

Страница 3: ...wed to be used by children aged from 8 years old and above and persons with reduced physical sensory or mental capabilities or no experience and knowledge provided that they have been given supervisio...

Страница 4: ...th _ 153 135 500 mm L 153 135 1000 mm Rated air capacity m3 h Control system type W Wi Fi connection of ventilators Air duct section shape R round Ventilator series Minimum wall thickness for the unit...

Страница 5: ...ilters G3 MERV 7 Sound pressure level 1 m dBA Sones 30 1 1 37 2 0 40 2 5 Sound pressure level 3 m dBA Sones 21 0 4 28 0 9 31 1 1 Outdoor noise level attenuation dBA Sones 42 2 5 IP rating IP24 WI FI T...

Страница 6: ...off Indoor unit rear side The unit includes a circuit control board and touch buttons Mounting frame Facilitates mounting of the ventilator in thin walls with the thickness from 135 mm Outer ventilati...

Страница 7: ...in the figure below A A A A 120 min 300 min 300 min 300 2 Insert the air duct in the wall hole For ease of installation use the polystyrene wedges included in the delivery set The air duct end must pr...

Страница 8: ...0 123 36 5 Mounting template for the back part of the indoor unit Mounting template for the mounting frame 4 Pull the lug on the bottom to disconnect the front panel of the indoor unit from the rear p...

Страница 9: ...9 www ventilation system com 6 Insert the cartridge into the air duct and insert the plug cartridge to the controller Re install the front panel of the indoor unit rear part...

Страница 10: ...n Connect the ventilator to power supply through an automatic circuit breaker with electromagnetic trip integrated into the home wiring system The rated trip current of the automatic circuit breaker o...

Страница 11: ...mming mode can be switched by the service engineers only VENTILATOR CONTROL Ventilation The ventilator operates in the supply or extraction mode at a set speed On Off Speed The speed selection sequenc...

Страница 12: ...place the filters see the Technical maintenance section After replacement of the filters reset the filter timer using the mobile application or press and hold the button on the indoor unit of the Mast...

Страница 13: ...cess point with the name FAN 16 ID Number characters stated on the ventilator casing under the front panel Wi Fi access point password 11111111 1 2 4 5 6 8 7 3 Enter the Vents TwinFresh V 2 app and cr...

Страница 14: ...tilator Home connection or connection via a cloud server through Internet respectively Maximum speed activation indicator It goes on after actuation of the humidity or any other connected external rel...

Страница 15: ...sor to the standard status To set up sensor operation via the mobile application go to Menu Settings Sensors Humidity sensor actuation of the humidity sensor When the indoor humidity exceeds the set p...

Страница 16: ...and time The ventilator filters must be serviced after every 90 hours of continuous operation The need to replace the filters is communicated by the indicator in the upper section of the Control menu...

Страница 17: ...go to Menu Connection WI FI setup Press the Receive button to display the current Wi Fi settings Select one of the Wi Fi operation modes Access point access point mode without a home router Select th...

Страница 18: ...t Wiring diagram 1 Connection of up to 8 Slave units or mobile devices to the Master unit with its own wireless access point Wiring diagram 2 The Master units the Slave units and the mobile devices ar...

Страница 19: ...to the ventilator functions To enter the special setup mode press and hold the Ventilation button on the ventilator casing for 5 seconds until the beep and blinking of all the LED lights The ventilato...

Страница 20: ...ay result in temporary loss of communication with the ventilator To control the master ventilator create a new account during the first connection through the cloud server Re use the account for all f...

Страница 21: ...tor do not pull the cable Uplift it with a flat screwdriver of a respective size 3 Remove the cartridge from the air duct 4 Remove the filters from the cartridge for cleaning 5 After cleaning of the f...

Страница 22: ...oose screw connection in the ventilator casing or in the outer ventilation hood Tighten the screws of the ventilator or the outer ventilation hood STORAGE AND TRANSPORTATION REGULATIONS Store the unit...

Страница 23: ...ler for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including s...

Страница 24: ...24 TwinFresh Expert RW 30 V 2 www ventilation system com...

Страница 25: ...25 www ventilation system com...

Страница 26: ...26 TwinFresh Expert RW 30 V 2 www ventilation system com...

Страница 27: ...heTwinFresh Expert RW _________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Tec...

Страница 28: ...V133 5EN 03...

Отзывы: