The isolation transformer TRF-220/12-25, called hereinafter " the transformer", is intended for the household 
fans power supply of ultra-low secure voltage 12 V / 50 Hz , in which the motor's power does not exceed 16 W.

   BASIC TECHNICAL CHARACTERISTICS

Supply voltage  220-240 V, 50 Hz.
Target voltage  12 V, 50 Hz.
Maximal load power, no more  25 W

A

 (load current no more than 2 A). 

The transformers belong to devices of the Class II insulation by type of protection against electric-shock 
hazard.
Overall dimensions of the transformer, no more  91x58x62 mm.
Overall dimensions of the protective terminal box, no more  110x40x40 mm.
Weight, no more - 0,8 kg.
Protection Class concerning dust and moisture (except for the terminal blocks)  IР40.
Transformer operation conditions  100C +400С and relative humidity of no more than 75 %.
The ambient air should contain no explosive and corrosive impurities.

   SAFETY REQUIREMENTS

The maintenance and installation should be carried out by the person who has the admission to the 
independent work with the electrical installations up to 1000 V and has studied this manual. 

Attention! 

The transformer input circuit is under network potential. The transformer installation and 

connection should be made only after its disconnection from the network system..

Forbidden!

- To operate the defective transformer,
- To make alterations to the scheme,
- To transfer the energized transformer,
- To operate the transformer with a damaged isolation of network cable and output cables ,
- To connect and disconnect output cables if the transformer is turned on,
- To overload the transformer electrically.

Not allowed! 

- Water ingress in design elements of the transformer, 
- No explosive and corrosive impurities should be present in air. 

   DELIVERY SET 

The delivery set contains:
Isolation transformer TRF-220/12-25 ready-assembled with protective terminal box,

- c

ertificate, 

- s

pare safety fuse 0,25 A / 250 V, 

- p

acking box.

 

ACCEPTANCE CERTIFICATE

The isolation transformer TRF-220/12-25 is recognized to be serviceable

V32EN -01

   STORAGE AND TRANSPORTATION

The transformer should be stored in manufacturer packaging in closed and aired room without the acid and 
other steams having a harmful effect on the materials and isolation at temperature from +5°С to +40°С and 
relative air humidity of no more than 80 % (at Т = 25°С).
The transformer in the manufacturer transport container can be transported by any kind of transport in 
covered vehicles.
Transportation of the transformer should be carried out according to the handling stamps on the packaging.

   MANUFACTURER'S GUARANTEES

The transformer TRF-220/12-25 corresponds to requirements of GOST 30030-93 (MEK 742-83)
“Isolation Transformers and Safe Isolation Transformers. Technical Requirements ”, DNAOP 0.00-1.32-01” 
Rules of the Electrical Installation Structure. Electrical Equipment of the Special Installations ",
" Rules of the Technical Operation of Electrical Installations”.

The manufacturer, Joint-Stock Company "VENTS", guarantees normal work of the transformer for 
12 months from the date of sale through the retail trading network provided transportation, storage, 
installation and operation rules are complied with. The guarantee does not apply to the products with signs 
of the mechanical damages. In case of malfunction in transformer work because of the manufacturer within
The warranty period, the consumer has the right for the transformer replacement. In the absence of sale date 
mark, the warranty period is estimated from the date of manufacturing.

Replacement is made under the address:

1, Kotzubinskogo street, 01030, Kiev, Ukraine

Sale date                                                                            Manufacturing date

SELLER                                                                              Approval mark

1

Отзывы: